Go to page of
Similar user manuals
-
Air Conditioner
Haier HSU-12LQA13/R2(DB)-WT
8 pages 1.95 mb -
Air Conditioner
Haier AD182AMBEA(ECO)
19 pages 0.33 mb -
Air Conditioner
Haier AD242AHBEA
22 pages 0.44 mb -
Air Conditioner
Haier HC42D2VAR
17 pages 9.03 mb -
Air Conditioner
Haier HSU-18HEA03/R2-I
13 pages 0.79 mb -
Air Conditioner
Haier AU092ABNCA
19 pages 2.97 mb -
Air Conditioner
Haier HSU-18LE03
18 pages 0.29 mb -
Air Conditioner
Haier HSU-12HQA03/R2(DB)
16 pages 4.7 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Haier 001051, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Haier 001051 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Haier 001051. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Haier 001051 should contain:
- informations concerning technical data of Haier 001051
- name of the manufacturer and a year of construction of the Haier 001051 item
- rules of operation, control and maintenance of the Haier 001051 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Haier 001051 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Haier 001051, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Haier service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Haier 001051.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Haier 001051 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
No.00105 1 Installation Man ual of Room Air Conditioner Drawing f or the installation of indoor and outdoor units Read this manual bef ore installation 1.Driver 2.Hacksa w 3.Hole core drill 4.Spanner(17,19 and 26mm) 5.Torque wrench(17mm,22mm,26mm) 6.Pipe cutter 7.Flaring tool 8.Knif e 9.Nipper 12.Reamer 10.Gas leakage detector or soap-and-water sol[...]
-
Page 2
2 Fixing of outdoor unit Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally. When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind. If vibration may affect the house, fix the unit by attaching a vibration-proof mat. Indoor U[...]
-
Page 3
2.Making a Hole on the W all and Fitting the Piping Hole Cover When the mounting plate is fixed side bar and lintel Refer to the previous article, " When the mounting plate is first fixed ", for the position of wall hole. Fix to side bar and lintel a mounting bar, Which is separately sold, and then fasten the plate to the fixed mounting b[...]
-
Page 4
Indoor unit 3.Installation of the Indoor Unit Drawing of pipe Rear piping Left Left-rear piping Draw pipes and the drain hose, then fasten them with the adhesive tape In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for le[...]
-
Page 5
Indoor unit When connecting the cable after installing the indoor unit 1. Inser t from outside the room cable into left side of the w all hole, in which the pipe has already e xisted. 2. Pull out the cable on the front side, and connect the cab le making a loop. When connecting the cable bef ore installing the indoor unit Inser t the cable from the[...]
-
Page 6
Outdoor unit 1.Installation of Outdoor Unit 2.Connection of pipes Install according to To bend a pipe , give the roundness as large as possible not to crush the pipe ,and the bending radius should be 30 to 40 mm or longer. Connecting the pipe of gas side first makes w orking easier. The connection pipe is specialized f or R410A. Drawing f or the in[...]
-
Page 7
Outdoor unit 5.Purging Method:T o use v acuum pump Detach the service por t's cap of 3-way v alve , the valv e rod's cap for 2-wa y valv e and 3-way's, connect the service por t into the projection of charge hose (low) f or gaugemanif old. Then connect the projection of charge hose (center) for gaugemanif old into vacuum pump . T ube[...]
-
Page 8
1.Cut pipe 3.Inser t the flare nut 4.Flare pipe It becomes high midwa y. The end is immersed in water. It wav es. The gap with the ground is too small Less than 5cm There is the bad smell from a ditch 2.Remov e burs 0~0.5mm 1.0~1.5mm 1.5~2.0mm Flare tool for R410A Clutch-type Conv entional flare tool clutch-type(Rigid-type) Wing-nut type (Imperial-[...]
-
Page 9
CE T utti i prodotti sono conformi alle seguenti normative europee: - Dir ettiva 73/23/EEC Basso V oltaggio - Dir ettiva 2006/95/EC Basso V oltaggio - Dir ettiva 89/336/EEC Compatibilità elettromagnetica - Dir ettiva 2004/108/EC Compatibilità elettromagnetica ROHS Il prodotto è conforme alla normativa 2002/95/EEC sulla r estrizione d’uso di so[...]
-
Page 10
Haier Industrial Park, No.1 Haier Road, Qingdao, P .R.China CE T odos los productos están en conformidad con las siguientes Normativas Europeas: - Bajo V oltaje directiva 73/23/EEC - Bajo V oltaje directiva 2006/95/EC - Compatibilidad electr omagnética 89/336/EEC - Compatibilidad electr omagnética 2004/108/EC ROHS Los productos cumplen los r equ[...]
-
Page 11
Questo prodotto contiene gas fluorurati ad ef fetto serra inclusi nel Protocollo di Kyoto. Non liberare tali gas nell’atmosfera. Tipo di refrigerante: R410A V alore GWP*: 1975 * GWP = potenz iale di riscaldamento globale Compilare con inchiostr o indelebile, • 1 la carica di refrigerante di fabbrica del pr odotto • 2 la quantità di refrigera[...]
-
Page 12
Haier Industrial Park, No.1 Haier Road, Qingdao, P .R.China 1 1+2= kg R410A 2 kg 2= 1= B C D FE kg Contain s fluorinated greenhou s e ga s e s covered by the Kyoto Pr otocol A Este producto contiene los gases fluorados de efecto invernadora regulados por el Protocolo de Kioto. No vierta gases a la atmósfera. Tipo de refrigerante: R410A V alor GWP*[...]