Haier AB212XCEAA manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Haier AB212XCEAA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Haier AB212XCEAA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Haier AB212XCEAA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Haier AB212XCEAA should contain:
- informations concerning technical data of Haier AB212XCEAA
- name of the manufacturer and a year of construction of the Haier AB212XCEAA item
- rules of operation, control and maintenance of the Haier AB212XCEAA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Haier AB212XCEAA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Haier AB212XCEAA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Haier service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Haier AB212XCEAA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Haier AB212XCEAA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Please read this operation manual before using the air conditioner . No.0010577706 Operation & Installation Manual CASSETTE TYPE AIR CONDITIONER Please keep this manual carefully and safely . AB212XCEAA[...]

  • Page 2

    Contents Cautions ............................................................................................. Introduction to Spare Parts ................................................................... Maintenance ....................................................................................... T rouble Shooting ........................[...]

  • Page 3

    Cautions 1 Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The v[...]

  • Page 4

    2 All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner . Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting an[...]

  • Page 5

    3 W ARNING! Carefully r ead the following information in order to operate the airconditioner correctly . Below are listed three kinds of Safety Cautions and Suggestions. W ARNING! CAUTION! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences. Incorrect operations may result in severe consequen[...]

  • Page 6

    4 CAUTIONS! Conditioner should not be used for any other purpose other than air conditioning. Don't use air-conditioner for any other special purposes, e.g. the preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these stuffs may be damaged. Don't dismantle the outlet[...]

  • Page 7

    Intr oduction to Spar e Parts 5 Drain Hose Swing fender Refrigerant pipe Cable line Earthing line Air filter Outlet Suction grill (located in the suction grill) In cooling operation, to discharge the water from inside the room. Discharge unit (built in) (located in the outlet)[...]

  • Page 8

    6 3. Dismantle air filter CAUTION! 4. Clean 6. Close inlet grill 7. Press the filter signal return key on the controller . (A) Remove dust with vacuum filter . 5. Install air filter (1) Put filter into protruding parts at the top of the inlet grill. (2) Connect the two pothooks with inlet grill See 2 [Clean inlet grill] 1. Open inlet grill See 1. C[...]

  • Page 9

    Maintenance 7 3. T ake of inlet grill 4. Clean CAUTION! NOTE When the filter too much dust T o spray the special detergent for vent fan or utensils. 5. Install inlet grill 6. Install air filter 7. Close inlet grill [Clean outlet and shell] see 3 see "Clean air filter" see 1 CAUTION! Don't use gasoline, benzene, dilutant, polishing po[...]

  • Page 10

    8 NOTE The inner part of indoor unit must be cleaned. Consult dealer , because clean must be done by technician. In cooling operation, discharging system discharge water in r oom. 2. 1. Seasonal Reserve Operate the unit with F AN mode on a fair day for about half a day to dry the inside of the unit well. Stop operation and turn off the power supply[...]

  • Page 11

    9 The followings are not malfuncition Hua Hua T r ouble Shooting W ater flowing sound is heard When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is the flowing sound of the refrigerant , not a malfunction. Cracking s[...]

  • Page 12

    10 **? ON OFF T r ouble Shooting Air does not blow or the fan speed cannot be changed during drying. In DR Y mode, when room temperature becomes 2 C higher than temperature setting, unit rill run intermittently at LO speed regardless of F AN setting During heating,indoor fan is still running even unit is stopped. T o get ride of the excess heat, in[...]

  • Page 13

    1 1 When T rouble Happens Insufficient cooling or heating The operation controller adjusted as required Air filter too dirty ? Horizontal swing louver upward ? (in HEA T mode) Any obstacle exists at the air inlet or outlet? Door or window left opened ? Insufficient cooling Any other heat sources in the room? Sunlight direct into the room ? T oo cro[...]

  • Page 14

    12 Customer Need-to-know Customer Need-to-know Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner . Please keep the installation manual for future reference when maintenance and changing[...]

  • Page 15

    13 W ARNING ! CAUTION ! Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Incorrect installation may cause water leaking, shock and fire hazard. Please call dealer to install the air -conditioner . Air -conditioner can't be installed in the envi[...]

  • Page 16

    14 Unit shall be grounded. But grounding shall not be connected to gas pipe water pipe, telephone line. Poor grounding will cause electric shock. Be sure to install a leakage breaker to avoid electric shock. Arrange water drainage according to this Manual. Cover pipe with insulation materials in case dew may occur . Unproper installation of water d[...]

  • Page 17

    15 Installation tools 1. Screw driver 2. Hacksaw 3. Drill with a diameter of 60mm 4. Inner hexagon spanner ,shifting spanner 5. Spanner (14, 17, 19,24,27mm) 6. Pipe cutter 7. Pipe expander 8. Knife 9. Pincers 10. Leakage detector or soapy water 1 1. Band tape 12. Scraper 13. Refrigerant oil The installation tools listed in the following sheet can b[...]

  • Page 18

    3. PREP ARA TION FOR THE INST ALLA TION (1) Position of ceiling opening between unit and suspending bolt. 3 16 (2) Cut an opening in ceiling for installation if necessary . (when ceiling already exists.) (3) Install a suspending bolt. (Use a M10 bolt) T o support the unit weight, anchor bolt shall be used in the case of already exists ceiling. For [...]

  • Page 19

    17 4. INST ALLA TION OF INDOOR UNIT In the case of new ceiling < After installation on the ceiling > (3) Adjust unit to its right position. (Refer to preparation for the installation-(1)) (4) Check unit's horizontal level. W atert pump and flating switch is installed inside indoor unit, check four corners of the unit for its level using [...]

  • Page 20

    6. INST ALLA TION OF W A TER DRAINAGE PIPE ( As for outdoor piping, please refer to installation Manual of outdoor unit. ) 5. REFRIGERANT PIPING Outdoor is precharged with refrigerant. Be sure to see the Fig.1, when connecting and removing piping from unit. For the size of the flare nut, please refer to T able 1. Apply refrigerant oil at both insid[...]

  • Page 21

    (2) Check if water drainage is smooth after installation. Charge, through air outlet or inspecting hole, 1200ccd water to see water drainage. After wiring Remove cover of control box, short connect "CHECK" terminal of the indoor unit, which is on the uper part of indoor unit PCB. Connect 1PH power to terminal 1 and 2 on terminal block. No[...]

  • Page 22

    20 As for outdoor unit circuit, please see Installation Manual of outdoor unit. Note: All electric wires have their own poles, poles must match that on terminal block. 9. INST ALLA TION OF ORNAMENT P ANEL 1. Prepar e ornament panel Handling of ornament panel Ornament panel shall not be placed face down or against wall, neither on an uneven object. [...]

  • Page 23

    21 (1) 3. Install ornament panel on indoor unit. As shown in Fig . 7, match the position of swing flap motor with that of the indoor unit piping hole , so that ormament panel can be placed on to indoor unit. Installation of ornament panel Place the holding ring on swing flao motor side teporarily on hooks of the indoor unit. (2 pcs) Put the other t[...]

  • Page 24

    22 Item to the checked Pay special care to the following and check after installation Unproper installation may cause Check Is indoor unit firmly installed? Is gas leakage check performed? Is unit properly insulated? Is water drainage smooth? Is power voltage meet that stipulated on the nameplate? Is wiring and piping correctly arranged? Is unit sa[...]

  • Page 25

    Installation Pr ocedur e After electric installation,power on them to do electric leakage test. The electric wiring work shall be conducted by qualified electricians according to the installation instructions. A separate power circuit shall be used. Insufficient power cord amperage or improper wiring will cause danger of electric shock or fire. Dur[...]

  • Page 26

    Wir e connection for built-in indoor unit Insert from outside the connection wire and signal transmission wire through the wall hole with pipeline already arranged. Pull out the front ends of connection wire and signal wire and make a circle on the signal wire. Connect the connection wire according to the connection method and indoor and outdoor wi[...]

  • Page 27

    Failur e code The remote receiver can indicate the failure code 25 For remote type, flash times 10 1 2 3 4 5 6 7 8 9 1 1 14 15 16 17 18 19 20 21 22 Failure code on wired control ler 08 01 02 4A 49 48 53 47 07 06 0B 4C 05 54 50 0C 4B 4D 32D 54D For central control, failure code 21 01 02 1 1 12 10 14 22 06 05 30 15 17 26 15 23 18 15 07 08 Failure des[...]

  • Page 28

    HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden ,Qianwangang Road , Economic Development Zone, Qingdao ,Shandong 266500, P .R.C W eb Site: http://www .haier .com[...]