Go to page of
Similar user manuals
-
Flat Panel Television
Haier L19A10B
26 pages 2.07 mb -
Refrigeration and freezing
Haier HRF-628ACR6
27 pages 14.39 mb -
Refrigerator
Haier HRF-393
10 pages 2.57 mb -
Welder
Haier HR-60/A
67 pages 4.65 mb -
Flat Panel Television
Haier LCD-42K40-HD
52 pages 4.43 mb -
Flat Panel Television
Haier L26M9
36 pages 4.63 mb -
Air Conditioner
Haier HSU-07HV03, HSU-09HV03, HSU-12HV03, HSU-18HV03, HSU-22HV03, HSU-12HVB03
27 pages 0.99 mb -
Air Conditioner
Haier AD092AMBHA
24 pages 0.65 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Haier AU282XHERA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Haier AU282XHERA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Haier AU282XHERA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Haier AU282XHERA should contain:
- informations concerning technical data of Haier AU282XHERA
- name of the manufacturer and a year of construction of the Haier AU282XHERA item
- rules of operation, control and maintenance of the Haier AU282XHERA item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Haier AU282XHERA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Haier AU282XHERA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Haier service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Haier AU282XHERA.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Haier AU282XHERA item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
R410A MUL TI SPLIT SERIES ROOM AIR CONDITIONER OUTDOOR UNIT INST ALLA TION MANUAL AU282XHERA AU342XHERA Please read this manual carefully before installing the units. Please keep this manual safely for future use. NO.0010577255 A[...]
-
Page 2
Cautions ....................................................................................................................... Safety precautions........................................................................................................ Installation accessories..........................................................................[...]
-
Page 3
Cautions 1 Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The v[...]
-
Page 4
4. The wiring method should be in line with the local wiring standard. 5. The power cable and connecting cable are self- provided. All the cables shall have got the local authentication certificate. During installation, when the connecting cables break off, it must be assured that the grounding wire is the last one to be broken off. 6. The breaker [...]
-
Page 5
3 Safety pr ecautions All units shall be earthed. The earth must not be connected to a gas pipe, water pipe, or telephone line. Poor earthing could cause electric shock. Be sure to install a circuit breaker to avoid electric shock. Arrange water drainage according to this manual. Cover pipe with insulation materials to prevent condensation occuring[...]
-
Page 6
4 (c) Where there is strong radiation. It will affect the unit's control system, causing malfunction of the unit. (d) Where there are flammable gas, dirt, and volatile matter (thinner , gasoline) exist, these items will cause a fire risk. The following accessories are supplied together with the outdoor unit. 580 185 185 380 416 Safety pr ecaut[...]
-
Page 7
5 1. Do not connected the embedded branch piping and the outdoor unit when only carrying out piping work without connecting the indoor unit in ordor to add another indoor unit later . Make sure no dirt or mositure gets into eigher side of the embedded branch piping. 2.It is impossible to connect the indoor unit for one room only . Be sure to connec[...]
-
Page 8
6 Matching of the indoor and outdoor units Remark 07 09 12 12 14 14 18 07 07 07 07 07 07 07 09 09 09 09 09 09 12 12 12 12 12 14 07 07 07 07 07 07 07 07 07 07 07 07 07 09 09 09 09 09 09 A B 18 18 14 18 14 18 18 07 07 07 09 09 09 09 09 09 09 09 12 12 12 12 12 14 14 14 07 07 07 07 07 07 07 07 07 09 09 09 09 09 09 09 09 09 12 C - - - - - - - 12 14 18 0[...]
-
Page 9
7 Matching of the indoor and outdoor units Remark 12 14 14 18 07 07 07 07 07 09 09 09 09 09 09 12 12 12 12 12 14 14 07 07 07 07 07 07 07 07 07 07 07 07 07 07 07 07 07 09 09 09 09 09 09 09 12 A B 18 14 18 18 07 07 09 09 09 09 09 09 09 12 12 12 12 12 14 14 14 14 07 07 07 07 07 07 07 07 07 07 07 09 09 09 09 09 09 09 09 09 09 09 09 12 12 C - - - - 14 1[...]
-
Page 10
8 Outdoor unit capacity class Piping to each indoor unit T otal length of liquid piping between all units AU282XHERA AU342XHERA 25m max. 60m max. 2.Selecting a location for installation of the indoor units 1.Precautions on installation Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the c[...]
-
Page 11
9 The piping length information, please refer the following table. Descriptions Standard A, B, C,D liquid pipe A, B, C,D Gas pipe mm Item Maximum Unit L1 (one way) L2 (one way) L3 (one way) h H + H - mm m m m m m m Size of the liquid side connection pipe Pipe length when the compressor connects with two indoor units Drop between every two indoor un[...]
-
Page 12
10 Refrigerant piping work Forced fastening without careful centering may damage the threads and cause a leakage of gas. Pipe Diameter ( ) Fastening T orque Liquid Side 6.35mm (1/4'') 18N.m Gas Side 9.52mm (3/8'') 50N.m 3. Attaching Drain-Elbow If the drain-elbow is used, please attach it as figure. Flare nut Half union T orque [...]
-
Page 13
1 1 4.Cutting and Flaring work of piping Pipe cutting is carried out with a pipe cutter and burs must be removed. After inserting the flare nut, flaring work is carried out. Less than 5cm It becomes high midway . The end is immersed in water It waves. It gap with the ground ts too small. There is the bad smell from a ditch. Please pour water in the[...]
-
Page 14
12 In case of gas leakage, tighten parts of pipe connection. If leakage stops, then proceed 6 steps. 9.52mm (3/8") 6.35mm (1/4") 9.52mm (3/8") 6.35mm (1/4") 9.52mm (3/8") 9.52mm (3/8") 6.35mm (1/4") 6.35mm (1/4") T o indoor unit C T o indoor unit D T o indoor unit B 2 way valve 3 way valve T o indoor unit A 3[...]
-
Page 15
1. Electric wiring Note: The air conditioner must use special circuit , and wiring by the qualified electrician according to the wiring rules specified in national standard. The grounding wire and the neutral wire shall be strictly separated. Connect the neutral wire with grounding wire is incorrect. The electric leakage breaker must be installed. [...]
-
Page 16
14 3. W iring method of outdoor unit: Loosen wire cover and connect the power line and communication wire of indoor unit to the terminal correspondingly . Note: When connecting power line to power supply terminal, please pay attention to the following items: Do not connect the power line with different dimensions to the same connection wire end. Im[...]
-
Page 17
15 5. Example wiring diagram. Please refer to the indoor unit installation manual to find detailly how to set and check the communication address. Incorrect address setting will cause abnormal to the system. 6. After installation, please fill in the following table for easy daily maintenance: Indoor unit NO. A B C D Model of indoor unit Serial no. [...]
-
Page 18
16 Items to confirm T est running Before starting the test running, please confirm the following works have been done successfully . 1) Correct piping work; 2) Correct wiring work; 3) Correct match of indoor and outdoor unit; 4) Proper recharge of refrigerant if needed; 5) Correct indoor unit addresses setting. Make sure that all the stop valves ar[...]
-
Page 19
17 T rouble shooting F AILURE CODE ST A TE OF LED 5-4-3-2-1 TROUBLE SHOOTING POSSIBLE REASONS DC fan motor fault Fan is blocked, or the terminal is disconnected from the PCB Faulty 4-way valve switching on Coil of 4-way valve is disconnected, or faulty outdoor PCB Abnormal communication between main PCB and SPDU(or ISPM) Communication cables broken[...]
-
Page 20
HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266555, P .R.China W eb Site: http://www .haier .com[...]