Go to page of
Similar user manuals
-
Air Conditioner
Haier HWF08XC5
23 pages 1.11 mb -
Air Conditioner
Haier HWE10XCN
79 pages 4.77 mb -
Air Conditioner
Haier ESA424K
44 pages 2.89 mb -
Air Conditioner
Haier HBU-42CH03
28 pages 0.61 mb -
Air Conditioner
Haier HSU-18HEK03/R2(DB)
8 pages 0.82 mb -
Air Conditioner
Haier AD362AMEAA
22 pages 0.33 mb -
Air Conditioner
Haier AS072AZBDA
20 pages 2.31 mb -
Air Conditioner
Haier AB124FAAHA
31 pages 0.62 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Haier HSU-24HK0307, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Haier HSU-24HK0307 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Haier HSU-24HK0307. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Haier HSU-24HK0307 should contain:
- informations concerning technical data of Haier HSU-24HK0307
- name of the manufacturer and a year of construction of the Haier HSU-24HK0307 item
- rules of operation, control and maintenance of the Haier HSU-24HK0307 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Haier HSU-24HK0307 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Haier HSU-24HK0307, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Haier service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Haier HSU-24HK0307.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Haier HSU-24HK0307 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
No .0010554405 B Installation Man ual of Room Air Conditioner No . Accessor y par ts Remote controller R-03 dry batter y Mounting plate Drain hose Steel nail, cement Screw Plastic cap Drain-elbow Cov er Cushion Connecting cable 1 1 A B C D E F G 2 3 4 5 6 7 8 9 10 2 1 1 6 4 1 1 4 1 Number of articles Accessory par ts Optional par ts for piping Mark[...]
-
Page 2
Fixing of outdoor unit Indoor Unit Selection of Installation Place Power Source Selection of pipe Outdoor Unit Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally . When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind. If vi[...]
-
Page 3
Indoor unit 1.Fitting of the Mounting Plate and Positioning of the wall Hole 2.Making a Hole on the W all and Fitting the Piping Hole Cover When the mounting plate is first fixed When the mounting plate is fixed side bar and lintel 1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall[...]
-
Page 4
Indoor unit 4.Connecting the indoor/outdoor Electric Cable Fixing the indoor unit body Removing the wiring cover [Other direction piping] Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape. Cut away , with a nipper , the lid for piping according to the piping direction and then bend the pipe accord[...]
-
Page 5
Indoor unit 2.Another way for the models of 18,22 ,24,as illustrated: W ay One (right direction): T ake off the lid for right piping pipe,put the Outlet joint into the lid,then put the fresh air tube into the outlet jont. W ay T wo (left direction): T ake off the lid for leftt piping pipe,put the Outlet joint into the lid,then put the fresh air tub[...]
-
Page 6
Outdoor unit 1.Installation of Outdoor Unit 3.Connection 4.Attaching Drain-Elbo w 2.Connection of pipes Install according to T o bend a pipe, give the roundness as large as possib le not to crush the pipe ,and the bending radius should be 30 to 40 mm or longer . Connecting the pipe of gas side first makes w or king easier . The max v er tical dista[...]
-
Page 7
Outdoor unit 6.Purging Method: 1.Remov e the four scre ws of fresh air box from the bac k cov er . 2.Use six screws to fix fresh air bo x onto the designated position on the outdoor unit. 3.Remov e two screws of the pipe junction of the fresh air bo x, then inser t the flared depar ture of the change f or fresh air tube into the pipe junction and t[...]
-
Page 8
1.Cut pipe 3.Inser t the flare nut 4.Flare pipe It becomes high midwa y . The end is immersed in water . It wav es. The gap with the ground is too small Less than 5cm There is the bad smell from a ditch 2.Remov e burs 1.P ower Source Installation 2.Cutting and Flaring W ork of Piping 3.On Drainage Chec k for Installation and T est Run Chec k Items [...]