Go to page of
Similar user manuals
-
Plumbing Product
Hans Grohe 06596000
1 pages 0.06 mb -
Plumbing Product
Hans Grohe 42234000
1 pages 0.1 mb -
Plumbing Product
Hans Grohe 40833XX0
1 pages 0.08 mb -
Plumbing Product
Hans Grohe 28547XX1
1 pages 0.12 mb -
Plumbing Product
Hans Grohe 31701001
16 pages 1.11 mb -
Plumbing Product
Hans Grohe 32XX
1 pages 0.61 mb -
Plumbing Product
Hans Grohe 40516XX0
1 pages 0.1 mb -
Plumbing Product
Hans Grohe 28570003
12 pages 0.27 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Hans Grohe ShowerArc 26396001, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hans Grohe ShowerArc 26396001 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Hans Grohe ShowerArc 26396001. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Hans Grohe ShowerArc 26396001 should contain:
- informations concerning technical data of Hans Grohe ShowerArc 26396001
- name of the manufacturer and a year of construction of the Hans Grohe ShowerArc 26396001 item
- rules of operation, control and maintenance of the Hans Grohe ShowerArc 26396001 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hans Grohe ShowerArc 26396001 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hans Grohe ShowerArc 26396001, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hans Grohe service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hans Grohe ShowerArc 26396001.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Hans Grohe ShowerArc 26396001 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
ShowerArc 26396001 Installation Instructions / W arranty[...]
-
Page 2
2 ShowerArc 26396001 Minimum ceiling height – 90 1/2”[...]
-
Page 3
3 For best results, Hansgrohe recommends that this unit be installed by a licensed, professional plumber . Please read over these instructions thor- oughly before beginning installation. Make sure that you have all tools and sup- plies needed to complete the installation. Inspect the ShowerArc thoroughly for ship- ping damage before beginning insta[...]
-
Page 4
4 Installation in 90º corner: Instructions begin on page 5 W all-to-wall installation Requires 26397000 installation kit (included): Instructions begin on page 13. Roughing-in The ShowerArc requires 1/2” NPT female fittings, recessed 3/8” behind the surface of the finished wall, for the hot and cold water supplies for the thermostatic mixing v[...]
-
Page 5
5 Only one set of supplies is required – do not install two sets of supplies . Installation in 90º corner The thermostatic mixing valve may be installed on either wall. This diagram shows both possible positions for the installation.[...]
-
Page 6
6 Installation in 90º Corner Seal the wall around the supplies with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 3 4[...]
-
Page 7
7 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 5 6 7 8[...]
-
Page 8
8 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Be careful not to drill into water lines! 9 10 11 12 6 mm[...]
-
Page 9
9 13 14 15 16[...]
-
Page 10
10 1 2 17 18 19 20 6 mm[...]
-
Page 11
11 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 21 22 23 24 6 mm[...]
-
Page 12
12 T urn to page 22 to continue the installation. Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 25 26[...]
-
Page 13
13 The thermostatic mixing valve may be installed on either wall. The diagram shows both possible positions for the installation. Only one set of supplies is required – do not install two sets of supplies . W all-to-W all Installation[...]
-
Page 14
14 W all-to-W all Installation Seal the wall around the supplies with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 3 4[...]
-
Page 15
15 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 5 6 7 8[...]
-
Page 16
16 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Be careful not to drill into water lines! 1 2 6 mm 12 9 10 11[...]
-
Page 17
17 Install the 26397000 mounting set 13 14 15 16[...]
-
Page 18
18 XX 90 XX = 17 18 19 20[...]
-
Page 19
19 6 mm SW 3 mm M6x8 1 2 24 21 22 23[...]
-
Page 20
20 Install the 26397000 mounting set M6x60 1. 2. 3. SW 3 mm M6x8 25 26 27 6 mm 28 Seal the wall around the an- chors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2[...]
-
Page 21
21 T urn to page 22 to continue the installation. SW 3 mm M6x8 29[...]
-
Page 22
22 Install the Cover , Escutcheon, and Handle Install the Showerhead and Handshower 2 1[...]
-
Page 23
23 Reset the High T emperature Limit Stop Loosen the handle screw with a 3 mm Allen wrench. Remove the retainer clip and stop ring from the stem. T ur n the stop unit to the handshower position. T ur n the temperature control stem until the output water is the desired high temperature -- usually 110º. KLICK 1 2 3 4[...]
-
Page 24
24 T ur n the stop unit to the off position. Install the stop ring so that the tooth is against the stop. Install the clip. Install the handle. T ighten the handle screw with a 3 mm Allen wrench. KLICK SW 3 mm 5 6 7[...]
-
Page 25
25 Justify the Handle T ur n the diverter handle to the handshower position. T ur n the temperature control knob until the output water is 100ºF . T ur n the diverter handle to the off position. Loosen the handle screw with a 3 mm Allen wrench. Remove the handle. Align the indexing mark on the temperature control knob with the 100º mark. Replace [...]
-
Page 26
26 User Instructions Using the Handshower T ur n the function lever to until the desired spray mode has been obtained. T ur n the temperature control knob to change the tem- perature. T ur n it clockwise to make the water cooler , counter-clockwise to make the water warmer . When the knob is turned counter-clockwise to the 100º position it will st[...]
-
Page 27
27 If necessar y , pour about 3/4” of a commercial scale remover , such as Lime-A way or CLR, into a shallow dish. Soak the spray face for the amount of time shown in the label instructions. Rinse the spray face with clear water . Reinstall the handshower . Flush the handshower for at least one minute before using. The handshower uses the Rubit?[...]
-
Page 28
28 Replacement Parts 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 17 25[...]
-
Page 29
29 1 wall flange 96768000 2 escutcheon 96767000 3 branch connection 97496000 4 branch connection 97497000 5 shower hose 28276000 6 handshower 28504001 7 handshower holder 28321000 8 body spray 97603000 9 showerhead 97195001 10 handle 25971000 11 shutoff unit with selector 97976000 12 escutcheon 97491000 13 thermostat car tridge 94282000 14 noise re[...]
-
Page 30
30 Problem Possible Cause Solution Unit outputs both hot and cold water , but it does not mix not a product defect -- the hot and cold supplies are reversed correct the plumbing W ater temperature does not get hot enough high temperature limit stop not set correctly reset high temperature limit stop handle not justified justify the handle thermosta[...]
-
Page 31
31 Limited Lifetime Consumer W arranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either the United States or Canada. WHO IS COVERED BY [...]
-
Page 32
Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 T el. 770-360-9880 • Fax 770-360-9887 www .hansgrohe-usa.com US - Installation Instructions • Part No. 90404701 • Revised 12/2007 the product for use primarily for any other purpose, including, without limitation, a commercial purpose, this warranty extends only (i) for[...]