Hearth and Home Technologies 4100I-NL-B manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Hearth and Home Technologies 4100I-NL-B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hearth and Home Technologies 4100I-NL-B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Hearth and Home Technologies 4100I-NL-B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Hearth and Home Technologies 4100I-NL-B should contain:
- informations concerning technical data of Hearth and Home Technologies 4100I-NL-B
- name of the manufacturer and a year of construction of the Hearth and Home Technologies 4100I-NL-B item
- rules of operation, control and maintenance of the Hearth and Home Technologies 4100I-NL-B item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hearth and Home Technologies 4100I-NL-B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hearth and Home Technologies 4100I-NL-B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hearth and Home Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hearth and Home Technologies 4100I-NL-B.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Hearth and Home Technologies 4100I-NL-B item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DO NOT DISCARD THIS MANUAL NOTICE • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation. DO N O T DIS C AR D WA RN ING If the information in these ins truc tio ns i s n ot f oll owed [...]

  • Page 2

    4100-I ACT WOOD INSERT Page 2 September 1, 2008 R 250-7201E and Welcome to the Quadra-Fire Family ! Hearth & Home T echnologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durability , and performance. This commitment begins with our research of the market, [...]

  • Page 3

    Page  September 1, 2008 4100-I ACT WOOD INSERT 250-7201E R SAFETY & OVER VIEW OF APPLIANCE Dimensions ----------------------------------------------------- 4 Minimum Clearances to Combustibles ------------------ 5 Listings ---------------------------------------------------------- 6 Chimney Height & Draft and 2-10- Rule --------------[...]

  • Page 4

    4100-I ACT WOOD INSERT Page 4 September 1, 2008 R 250-7201E DIMENSIONS T OP VIEW SIDE VIEW FRONT VIEW 20-7/8" (50mm) 0 o 10-7/8" (276mm) 21-5/8" (549mm) 7-7/8" (200mm) 16-1/4" (41mm) C L 24" (610mm) 0" (762mm) 12-1/8" (08mm) 9-5/16" (15mm) 45-/4" (1 162mm) A B 0-7/8" (78[...]

  • Page 5

    Page 5 September 1, 2008 4100-I ACT WOOD INSERT 250-7201E R Hearth Extension A B C D F E Insert SideW all Maximum Mantel Depth - 10" (254mm) Fascia or T rim Mantel Thermal Protection USA & Canada USA CANADA A Sidewall to Stove 15" (381mm) 15" (381mm) B Mantel to Stove 26" (660mm) 23" (584mm) C T op Trim to Stove 20"[...]

  • Page 6

    4100-I ACT WOOD INSERT Page 6 September 1, 2008 R 250-7201E A VOID FIRE: T o ensure that insulation or any other com- bustible material does not contact the chimney , a chimney inside the house must have at least 2 inches (51mm) of air space clearance around t he chimney . A chimney outside the house must have at least one inch (25mm) clearance to [...]

  • Page 7

    Page 7 September 1, 2008 4100-I ACT WOOD INSERT 250-7201E R IF INST ALLING THIS MODEL T O A MASONRY CHIMNEY , AL W A YS BE SU RE TH E CHI MNEY IS IN G OO D CON DITI ON AND THA T I T MEET S THE MIN IMU M ST ANDAR DS OF THE        ?[...]

  • Page 8

    4100-I ACT WOOD INSERT Page 8 September 1, 2008 R 250-7201E Floor Ceiling Caulk Floor (second Story) Non-Combustible Firestopping Material  clearance from exterior   2 inch (51mm ) A chimn[...]

  • Page 9

    Page 9 September 1, 2008 4100-I ACT WOOD INSERT 250-7201E R 1. An outside air inlet must be provided for combustion and must remain clear of leaves, debris, ice and/or snow . It must be unrestricted while unit is in use to prevent room air starvation which can cause smoke spillage and an inability to maintain a re. Smoke spillage can also set of[...]

  • Page 10

    4100-I ACT WOOD INSERT Page 10 September 1, 2008 R 250-7201E MASONR Y FIREPLACE USING DIRECT -CONNECT METHOD ?[...]

  • Page 11

    Page 1 1 September 1, 2008 4100-I ACT WOOD INSERT 250-7201E R F ACTOR Y -BUIL T ZERO CLEARANCE FIREPLACE      Listed Liner Mantel SEAL DAMPER AREA OR FACE SEAL    ?[...]

  • Page 12

    4100-I ACT WOOD INSERT Page 12 September 1, 2008 R 250-7201E Leveling Bolts Sheet Metal Shims Place under leveling bolts and slide insert into place Leveling Bol t Reach between side of insert and outer skin cut-out view This product shipped with two leveling bolts, and two sheet metal guides for ease in sliding the insert into place when using the[...]

  • Page 13

    Page 1 September 1, 2008 4100-I ACT WOOD INSERT 250-7201E R SECURING LINER T O CHIMNEY RING There are two options to secure the liner to the chim- ney ring:  Option One: If there is enough room on the top of the insert to work, hand bend the two tabs upward 90°. Secure the liner with the supplied hex[...]

  • Page 14

    4100-I ACT WOOD INSERT Page 14 September 1, 2008 R 250-7201E P ANEL SET and CAST TRIM SET 1. Remove contents from box being careful not to scratch or damage cast trim pieces. 2. Lay the panel set face down on protective covering to prevent scratching the painted surface. . Secure panel set together with screws provided. ?[...]

  • Page 15

    Page 15 September 1, 2008 4100-I ACT WOOD INSERT 250-7201E R BLOWER CORD LOCA TION & BLOWER CONTROL BOX WITH SWITCH Remove Bolt Remove Bolt Remove 4 screws, lift motor from housing This insert comes standard with a blower , installed at the factory with blower cord on right side of insert (as you face the unit). The blower cord can also be inst[...]

  • Page 16

    4100-I ACT WOOD INSERT Page 16 September 1, 2008 R 250-7201E      ?[...]

  • Page 17

    Page 17 September 1, 2008 4100-I ACT WOOD INSERT 250-7201E R WOOD SELECTION AND STORAGE B urn only dry seasoned wood. Dry , well-seasoned wood will not only minimize the chance of creosote formation but will give you the most efcient heat output. Even dry wood contains at least 15% moisture by weight and should be burned hot enough to keep the c[...]

  • Page 18

    4100-I ACT WOOD INSERT Page 18 September 1, 2008 R 250-7201E 1 .   Leave fan of f until your insert is hot and a good coal bed is established, approximately 0 minutes after fuel is lit. 2.  The fan may be left on througho[...]

  • Page 19

    Page 19 September 1, 2008 4100-I ACT WOOD INSERT 250-7201E R Start-Up Air Control Primary Air Control  OPEN - PUSH IN CLOSE - PULL OUT BURNING PROCESS In recent years there has been an increasing concern about air quality . Much of the blame for poor air quality has been placed on the burning of wood for home heating. [...]

  • Page 20

    4100-I ACT WOOD INSERT Page 20 September 1, 2008 R 250-7201E MAINTENANCE CARE AND CLEANING OF PLA TED SURF ACES IMPORT ANT : Y ou must clean all the ngerprints and oils from the plated surfaces before ring the insert for the rst time. Use warm soapy water and a soft rag, glass cleaner and a paper towel, or vinegar and a paper towel to remo[...]

  • Page 21

    Page 21 September 1, 2008 4100-I ACT WOOD INSERT 250-7201E R 2  " 2-1/4" 1 1 2 2  4 4 4 4 4 4 4 4 4 4 6 6 4 4 5 5 5  The rebox is lined with high quality rebrick which has excep - tional insulating properties. There is no need[...]

  • Page 22

    4100-I ACT WOOD INSERT Page 22 September 1, 2008 R 250-7201E EXPLODED VIEWS  14.0" 10.0" 21-1/2"  Ceramic Blanket  1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 18 17 20 19 Item Description Item Description Item Description 1 Ashcatcher 8 Bafe, Fiberboard 15 Flue T ab 2 Blower , 180 cfm[...]

  • Page 23

    Page 2 September 1, 2008 4100-I ACT WOOD INSERT 250-7201E R IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on the Quadra-Fire web site at www .  . When ordering, supply serial and model numbers to ensure correct part. Service Parts and Accessories Item # Part Description A[...]

  • Page 24

    4100-I ACT WOOD INSERT Page 24 September 1, 2008 R 250-7201E 27 25 30 29 31 23 20 21 22 28 24 Item # Part Description Alphabetical Order   Accessories Part No. Cast T rim Set, Matte Black, 5 pc 81 1-090 Panel Set Standard, 0-1/2” h x 44-/4” w (order cast trim separately) 81-2010 Panel Set, Larg[...]

  • Page 25

    Page 25 September 1, 2008 4100-I ACT WOOD INSERT 250-7201E R Date of Service Performed By Description of Service [...]

  • Page 26

    4100-I ACT WOOD INSERT Page 26 September 1, 2008 R 250-7201E W arranty Policy    Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric [...]

  • Page 27

    Page 27 September 1, 2008 4100-I ACT WOOD INSERT 250-7201E R  HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or maintenance of the appliance not in accordance with the installation instructions; operating instructions and the list - ing agent identication label furnished with t[...]

  • Page 28

    R September 1, 2008 Page 28 • Do NOT discard this manual. • Important operating and maintenance instructions included. • Read, understand and follow these instruci- tons for safe installation and operation. • Leave this manual with party responsible for use and operation. CAUTION This product may be covered by one or more of the following p[...]