Hearth and Home Technologies CUMBGAP-MBK manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Hearth and Home Technologies CUMBGAP-MBK, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hearth and Home Technologies CUMBGAP-MBK one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Hearth and Home Technologies CUMBGAP-MBK. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Hearth and Home Technologies CUMBGAP-MBK should contain:
- informations concerning technical data of Hearth and Home Technologies CUMBGAP-MBK
- name of the manufacturer and a year of construction of the Hearth and Home Technologies CUMBGAP-MBK item
- rules of operation, control and maintenance of the Hearth and Home Technologies CUMBGAP-MBK item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hearth and Home Technologies CUMBGAP-MBK alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hearth and Home Technologies CUMBGAP-MBK, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hearth and Home Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hearth and Home Technologies CUMBGAP-MBK.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Hearth and Home Technologies CUMBGAP-MBK item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SA VE THESE INSTRUCTIONS www .quadrafire.com This manual contains instructions for Installation, Operation & Maintenance. Please read this entire manual before you install and use your new room heater . Failure to follow instructions may result in property damage, bodily injury , or even death. Cumberland Gap Non-Catalytic, Front/Side Load, W [...]

  • Page 2

    R Page 2 September 1, 2008 Cumberland Gap W ood Stove 7006-188E and Welcome to the Quadra-Fire Family ! H earth & Home T echnologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durability , and performance. This commitment begins with our research of the mar[...]

  • Page 3

    Page 3 Cumberland Gap W ood Stove R September 1, 2008 7006-188E SERIAL NUMBER LABEL & LOCA TION .................. 2 PRE-USE CHECKLIST .............................................. 3 LISTINGS & SAFETY NOTICES ............................... 4 I NST ALLA TIONS MA TERIAL NEEDED FOR SAFETY 4 VENTING SYSTEM ....................................[...]

  • Page 4

    R Page 4 September 1, 2008 Cumberland Gap W ood Stove 7006-188E LISTINGS and SAFETY NOTICES W ARNING ! DO NOT A TTEMPT TO OPERA TE THIS WOODSTOVE WITHOUT READING AND UNDERST ANDING THESE OPERA TING INSTRUCTIONS THOROUGHL Y . F AILURE TO OPERA TE THIS APPLIANCE PROPERL Y MA Y CAUSE A HOUSE FIRE. W ARNING! NEVER DRA W OUTSIDE COMBUSTION AIR FROM A W [...]

  • Page 5

    Page 5 Cumberland Gap W ood Stove R September 1, 2008 7006-188E DIMENSIONS FRONT VIEW SIDE VIEW VENT SPECIFICA TIONS : Single W all: Six inch (6”) (152mm) diameter , minimum 24 MSG black or blued steel connector pipe, with a listed factory-built chimney type UL103 HT* suitable for use with solid fuels, or a masonry chimney , and the referenced cl[...]

  • Page 6

    R Page 6 September 1, 2008 Cumberland Gap W ood Stove 7006-188E B A C1 Non-fuel door side D2 Fuel Door side C2 D1 CLEARANCES TO COMBUSTIBLES (UL and ULC) G (Ceiling) H E1 E2 F1 F2 Fuel door side Non-fuel door side G (Ceiling) Max Mantel Dept h 10" (254mm) G (Mantel) IF SIDE FUEL LOADING DOOR IS NOT USED: • Must remain in the locked position [...]

  • Page 7

    Page 7 Cumberland Gap W ood Stove R September 1, 2008 7006-188E FLOOR PROTECTION The floor must be non-combustible material, extending beneath heater and to the front/sides/rear as indicated. The floor must be a minimum of 1/2" thickness ("k" value = 0.84) non-combustible or otherwise adequately protected from radiant heat given of[...]

  • Page 8

    R Page 8 September 1, 2008 Cumberland Gap W ood Stove 7006-188E Calculating Alternate Floor Protection Material Thermal Conductivity: k value The k value indicates the amount of heat (in BTU’s) that will flow in 1 hour through 1 square foot of a uniform material 1 inch thick for each degree (F) of temperature difference from one side of the mate[...]

  • Page 9

    Page 9 Cumberland Gap W ood Stove R September 1, 2008 7006-188E WHEN LOCA TING YOUR STOVE consider safety , convenience, traffic flow , and the fact that the stove will need a chimney and chimney connector . It is a good idea to plan your installation on paper , using exact measurements for clearances and floor protection, before actually beginn[...]

  • Page 10

    R Page 10 September 1, 2008 Cumberland Gap W ood Stove 7006-188E The flue collar is reversible for either a top or rear venting installation. The unit is shipped with the flue collar in the top vent position. ACCESSOR Y HORIZONT AL FLUE SHIELD Part HTSHLD-7006 IS REQUIRED ON ALL HORIZONT AL INST ALLA TIONS. Figure10C CONVERTING COLLAR FOR REAR VE[...]

  • Page 11

    Page 1 1 Cumberland Gap W ood Stove R September 1, 2008 7006-188E T o be sure that your Quadra-Fire stove burns properly , the chimney draft (static pressure) should be approximately -.04” water column (W .C.) during a low burn and -.10” W .C. during a high burn, measured 6” (152mm) above the top of the stove after one hour of operation at ea[...]

  • Page 12

    R Page 12 September 1, 2008 Cumberland Gap W ood Stove 7006-188E Thimble Assembly: 12" (305mm) of brick separation between clay liner and combustibles. Fireclay liner 5/8" (16mm) Minimum or Equivalent. Sill support Header Wood Stud 2" (51mm) Clearance from chimney wall Fireclay liner 5/8" (16mm) Minimum or Equivalent. MASONR Y C[...]

  • Page 13

    Page 13 Cumberland Gap W ood Stove R September 1, 2008 7006-188E Figure 13B SOLID P ACK CHIMNEY WITH MET AL SUPPORTS AS A THIMBLE Add the 25" (635mm), center-line measurement to the depth measurement of your floor protector . Mark this combined measurement at the correct wall location for your installation, maintaining minimum clearance to co[...]

  • Page 14

    R Page 14 September 1, 2008 Cumberland Gap W ood Stove 7006-188E First, make the frame for the thimble, ensuring it is no smaller than 14" (356mm) square to maintain a 2" (51mm) air space around the chimney section. Attach the wall spacer to the chimney side of the frame. Then insert the frame into the opening, toe nailing it to the wall [...]

  • Page 15

    Page 15 Cumberland Gap W ood Stove R September 1, 2008 7006-188E When a metal prefabricated chimney is used, the manufacturer ’s installation instructions must be followed precisely . It will b e necessary to install the ceiling support package or wall pass through, “T” section package, firestops (when needed), insulation shield, roof flash[...]

  • Page 16

    R Page 16 September 1, 2008 Cumberland Gap W ood Stove 7006-188E Spark Arrestor Cap Roof Flashing Storm Collar Joist Shield/Firestop Listed Chimney Floor Protector Outside Air Kit Connector Outside Air Floor Vent 1 . An outside air inlet must be provided for combustion and must remain clear of leaves, debris, ice and/or snow . It must be unrestrict[...]

  • Page 17

    Page 17 Cumberland Gap W ood Stove R September 1, 2008 7006-188E I tems Needed for Installation : 4 in. (102mm) diameter flex pipe in the length as required for your installation; Phillips screwdriver; Silicone sealant; Drills and saws necessary for cutting holes through the wall or flooring in your home. Included in Kit: 2 cable ties; oustide ai[...]

  • Page 18

    Page 18 7006-188E R Cumberland Gap Wood Stove BENDING TEMPLA TE STRAIGHT END CUT ENDS Cut Ends Hand Bend #1 Cut Ends Straight End Hand bend #2 Lay the flat diverter on the template with the cut ends at the bottom of the tem- plate. HAND BEND #1 Bend the diverter to match the same degree bend as in the template. HAND BEND #2 Bend the diverter 90° [...]

  • Page 19

    Page 19 Cumberland Gap W ood Stove R September 1, 2008 7006-188E Cut end to the front Straight end to the back Ceramic Blanket Slanted corner Manifold chamber BAFFLE DIVERTER REQUIRED ON ALL HORIZONT AL INST ALLA TIONS 1. Open both doors. 2. Hold the diverter in a vertical position with the straight edge going in first and then rotate it to the in[...]

  • Page 20

    R Page 20 September 1, 2008 Cumberland Gap W ood Stove 7006-188E BURNING PROCESS In recent years there has been an increasing concern about air quality . Much of the blame for poor air quality has been placed on the burning of wood for home heating. In order to improve the situation, we at Quadra-Fire have developed cleaner-burning wood stoves that[...]

  • Page 21

    Page 21 Cumberland Gap W ood Stove R September 1, 2008 7006-188E FINAL ST AGE The final stage of burning is the charcoal stage. This occurs when the flammable gases have been mostly burned and only charcoal remains. This is a naturally clean portion of the burn. The coals burn with hot blue flames. It is very important to reload your stove while[...]

  • Page 22

    R Page 22 September 1, 2008 Cumberland Gap W ood Stove 7006-188E NOTE: These are approximate settings, and will vary with type of wood or chimney draft. Due to altitude and other environmen- tal circumstances, this operation information is a guideline only . Similar burn rates may be obtained using other settings unique to your situation. There are[...]

  • Page 23

    Page 23 Cumberland Gap W ood Stove R September 1, 2008 7006-188E CORRECT POSITION INCORRECT POSITIONS Firebox damage due to improper baffle place- ment is not covered by warranty . Operate the wood burning appliance with the baffle in the correct position only . Not doing so could result in: • Reduced efficiency • Overheating the chimney •[...]

  • Page 24

    R Page 24 September 1, 2008 Cumberland Gap W ood Stove 7006-188E OPERA TING INSTRUCTIONS (Cont’d) WOOD SELECTION AND STORAGE CAUTION: DO NOT STORE WOOD CLOSER THAN THE REQUIRED CLEARANCE T O COMBUSTIBLES OF THE STOVE WITHIN THE SP ACE REQUIRED FOR FUELING AND ASH REMOV AL Burn only dry seasoned wood! This will not only minimize creosote formation[...]

  • Page 25

    Page 25 Cumberland Gap W ood Stove R September 1, 2008 7006-188E CHIMNEY CLEANING FORMA TION AND NEED FOR REMOV AL: When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a newly-started or a slow-burning fire. A[...]

  • Page 26

    R Page 26 September 1, 2008 Cumberland Gap W ood Stove 7006-188E 1 . Ensure that the fire is out and the appliance is cool to the touch. 2. Protect a table or counter top with padding or towels. 3. Remove door with broken glass from the appliance by lifting door up and off of the hinges. 4. Lay door face down on a table or counter making sure hand[...]

  • Page 27

    Page 27 Cumberland Gap W ood Stove R September 1, 2008 7006-188E MAINTENANCE (Con'd) 1 1 1 1 2 2 3 3 7 4 5 5 5 6 6 5 5 5 5 BRICK REPLACEMENT INSTRUCTIONS Brick Set Part Number: BRICK-7006 T he firebox of your Quadra-Fire Cumberland Gap is lined with high quality firebrick which has exceptional insulating properties. There is no need for a gr[...]

  • Page 28

    R Page 28 September 1, 2008 Cumberland Gap W ood Stove 7006-188E 14-1/4" 23.0" 14.0" 5.0" 4-3/8" Ceramic Blanket 10 15 9 8 6 16 3 13 12 4 7 14 17 2 5 18 1 11 19 * Part number list on following page. Parts Diagram[...]

  • Page 29

    Page 29 Cumberland Gap W ood Stove R September 1, 2008 7006-188E Service Parts & Accessories 18 Ash Catcher , Front Matte Black 7006-156MBK 18 Ash Catcher , Front Porcelain (specify color) 7006-156POR 5 Ash Catcher , Side, Matte Black 7006-157MBK 5 Ash Catcher , Side, Porcelain (specify color) 7006-157POR 19 Ash Removal Door Assembly , with gas[...]

  • Page 30

    R Page 30 September 1, 2008 Cumberland Gap W ood Stove 7006-188E Item No. Accessories Serial No. Part No. Blower , 160 cfm 831-1701 Outside Air Kit 831-1780 Firescreen - Can only be used in Full V erticial Installations SCR-7006 9 Horizontal Flue Shield - Required for all Horizontal Installations HTSHLD-7006 Paint, T ouch-up, Porcelain Mahogany 855[...]

  • Page 31

    Page 31 Cumberland Gap W ood Stove R September 1, 2008 7006-188E Date of Service Performed By Description of Service Service & Maintenance Log[...]

  • Page 32

    R Page 32 September 1, 2008 Cumberland Gap W ood Stove 7006-188E Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and installed in the United States of Americ[...]

  • Page 33

    Page 33 Cumberland Gap W ood Stove R September 1, 2008 7006-188E  Noise resulting from minor expansion, contraction, or movement of certain parts is normal and complaints related to this noise are not covered by this warranty .  HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or ma[...]

  • Page 34

    R Page 34 September 1, 2008 Cumberland Gap W ood Stove 7006-188E This page intentionally left blank.[...]

  • Page 35

    Page 35 Cumberland Gap W ood Stove R September 1, 2008 7006-188E This page intentionally left blank.[...]

  • Page 36

    September 1, 2008 Page 36 7006-188E R • Do NOT discard this manual. • Important operating and maintenance instructions included. • Read, understand and follow these instruci- tons for safe installation and operation. • Leave this manual with party responsible for use and operation. CAUTION This product may be covered by one or more of the f[...]