Go to page of
Similar user manuals
-
Indoor Fireplace
Hearth and Home Technologies SL-750TRS-E
92 pages 7.45 mb -
Indoor Fireplace
Hearth and Home Technologies A36R/C
2 pages 0.4 mb -
Indoor Fireplace
Hearth and Home Technologies 36EBU
7 pages 0.54 mb -
Indoor Fireplace
Hearth and Home Technologies SL-750TRSFHHIPI
77 pages 5.26 mb -
Indoor Fireplace
Hearth and Home Technologies 6000GLX-IPI-S
72 pages 3.73 mb -
Indoor Fireplace
Hearth and Home Technologies Dakota 42
36 pages 2.38 mb -
Indoor Fireplace
Hearth and Home Technologies SL-950TV-D
53 pages 3.49 mb -
Indoor Fireplace
Hearth and Home Technologies SL-550TR-E
87 pages 7.41 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Hearth and Home Technologies NDV3630L, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hearth and Home Technologies NDV3630L one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Hearth and Home Technologies NDV3630L. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Hearth and Home Technologies NDV3630L should contain:
- informations concerning technical data of Hearth and Home Technologies NDV3630L
- name of the manufacturer and a year of construction of the Hearth and Home Technologies NDV3630L item
- rules of operation, control and maintenance of the Hearth and Home Technologies NDV3630L item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hearth and Home Technologies NDV3630L alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hearth and Home Technologies NDV3630L, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hearth and Home Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hearth and Home Technologies NDV3630L.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Hearth and Home Technologies NDV3630L item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 1 • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance. - DO NOT touch any electrical switch. DO NOT use any phone in your building. - Immediately call[...]
-
Page 2
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: _____________________ Dealership purchased from: ___________________[...]
-
Page 3
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous situation which, [...]
-
Page 4
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 4 Î = Contains updated information. 14 Appliance Setup A. Remove the Packaging 55 B. Open Front Screen Assembly 55 C. Remove the Shipping Materials 55 D. Remove Fixed Glass Assembly 55 E. Clean the Appliance 55 F . Accessories 55 G. Place the Rockwool 56 H. Place the Lava Rock 56 I. Plac[...]
-
Page 5
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 5 B. Limited Lifetime W arranty Gas Appliance (Fireplace) Limited Lifetime W arranty HEARTH & HOME TECHNOLOGIES INC. (“HHT”) extends the following warranty for HEA TILA TOR ® gas appliances installed in the United States of America or Canada (the "Appliance"). Dealers a[...]
-
Page 6
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 6 B. T empered Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as de fi ned by the Con- sumer Product Safety Commission (CPSC). The tempered glass has been tested and [...]
-
Page 7
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 7 G. Requirements for the Commonwealth of Massacusetts serves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. Exemptions The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4: • The equipment listed in Ch[...]
-
Page 8
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 8 2 2 Operat ing Instruc tions Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before reading and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury . DECORA TIVE [...]
-
Page 9
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 9 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects. Figure 2.2 Clear Space[...]
-
Page 10
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 10 I. Intermittent Pilot Ignition (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer . T o prolong battery life, remove them when using the transformer . A. This appliance is equipped with an ignition device which automatically lig[...]
-
Page 11
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 1 1 J. Standing Pilot Ignition A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air [...]
-
Page 12
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 12 Initial Break-in Procedure • The appliance should be run three to four hours continuously on high. • T urn the appliance of f and allow it to completely cool. • Remove and clean fi xed glass assembly . See Section 3. • Replace the fi xed glass assembly and run continuously on[...]
-
Page 13
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 13 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slamming glass • Avoid abrasive cleaners[...]
-
Page 14
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 14 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc. • V erify termination cap clearance to subsequent construc- tion [...]
-
Page 15
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 15 Figure 3.1 IPI Flame Patterns Figure 3.2 Standing Pilot Flame Patterns (Either cobrahead or SIT) PRODUCT SPECIFIC[...]
-
Page 16
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 16 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual CEILING FIRESTOP ON FLOOR OF A TTIC (SECTION 8.C.) VERTICAL T[...]
-
Page 17
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 17 B. Design and Installation Considerations Heatilator direct vent gas appliances are designed to oper- ate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required. Installation MUST comply [...]
-
Page 18
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 18 In addition to these framing dimensions, also reference the following sections: • Clearances and Mantel Projections (Sections 3.C. and 3.D.) • V ent Clearances and Framing (Section 6) Rear vent One 45° elbow Horiz T erm Rear V ent T wo 90° elbows Horiz T erm Rear V ent One 90° e[...]
-
Page 19
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 19 D Clearance to Ceiling 30 in. (762 mm) 0 in. 0 in. T O LEVEL OF ST ANDOFFS Combustible Object 36 in. (914 mm) 0 in. Combustible flooring may be installed next to the front of the appliance. Drywall 1/2 in. (13 mm) 1/2 in. (13 mm) C A B B. Constructing the Appliance Chase A chase is a v[...]
-
Page 20
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 20 1 in. (25 mm) min. to perpendicular wall A 3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall B Mantel Leg or Perpendicular W all T op of Appliance Drywall A B D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles [...]
-
Page 21
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 21 Measure vertical clearances from this surface. Measure horizontal clearances from this surface. A Gas T ermination Wood or Fuel Oil T ermination B 6 in. (152 mm) min. 20 in. (508 mm) min. Direct V ent Gas, Wood or Fuel Oil T ermination 20 in. (508 mm) (minimum) to Perpendicular W all ([...]
-
Page 22
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 22 CAUTIO N: IF E XT ERIO R WALLS AR E FINIS HED W ITH VI NY L SIDI NG, IT I S SUGGESTED TH A T A VIN YL PROTECTOR K IT BE I NST AL LED. D E B L C V V B F V B V V B X A J Fixed Closed M V K X RESTRICTION ZONE (TERMINA TION NOT ALLOWED) AIR SUPPL Y INLET X GAS METER V TERMINA TION CAP H B [...]
-
Page 23
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 23 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP and SLP venting systems. Refer to Sec- tion 16B for vent component information. DO NOT mix pipe, fi ttings or joining methods from dif ferent manufacturers. The pipe is tested to be run inside[...]
-
Page 24
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 24 T o replace the fi rst starter elbow with two 45° elbows, refer to Figure 7.4. All other 90° elbows can be replaced with two 45° elbows. General Rules: • SUBTRACT 3 ft. from the total H measurement for each 90° elbow installed horizontally . • SUBTRACT 1-1/2 ft. from the total[...]
-
Page 25
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 25 H 1 V 1 Figure 7.4 One Elbow 1. T op V ent - Horizontal T ermination - (continued) Figure 7.5 T wo Elbows Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally . Subtract 1-1/2 ft (457 mm) from the total horizontal measurement for[...]
-
Page 26
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 26 Figure 7.6 1. T op V ent - Horizontal T ermination - (continued) Three Elbows H 1 V 1 V 2 H 2 Installed V ertically V 1 min. V 1 +V 2 max. H 1 +H 2 max. 12 in./305 mm 24 ft/7.32 m (DVP) 19 ft/5.79 m 12 in./305 mm 22 ft/6.71 m (SLP) 19 ft/5.79 m Î[...]
-
Page 27
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 27 2. T op V ent - V ertical T ermination No Elbow Figure 7.7a 12 ft (3.66 m) min. 60 ft (18.29 m) max. Maximum horizontal run is 100% of vertical, but cannot exceed 26 ft (7.92 m) Figure 7.8 T wo Elbows 12 ft (3.66 m) min. 60 ft (18.29 m) max. Figure 7.7b Remove Flue V isor Figure 7.7c 1[...]
-
Page 28
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 28 Figure 7.9 2. T op V ent - V ertical T ermination - (continued) Three Elbows Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally . Subtract 1-1/2 ft (457 mm) from the total horizontal measurement for each 45° elbow installed ho[...]
-
Page 29
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 29 3. Rear V ent - Horizontal T ermination (DVP only) Figure 7.10 Figure 7.1 1 No Elbow One 45° Elbow 18 in. (457 mm) max. 18 in. (457 mm) max.[...]
-
Page 30
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 30 3. Rear V ent - Horizontal T ermination (DVP only) - (continued) T wo Elbows Figure 7.12 Figure 7.13 Three Elbows H 2 V 1 H 1 Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally . Subtract 1-1/2 ft (457 mm) from the total horizo[...]
-
Page 31
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 31 4. Rear V ent - V ertical T ermination (DVP only) One Elbow Figure 7.14 T wo Elbows Figure 7.15 12 ft (3.66 m) min. 60 ft (18.29 m) max. 0 min. 6 ft (1.83 m) max. Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally . Subtract 1-[...]
-
Page 32
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 32 4. Rear V ent - V ertical T ermination (DVP only) - (continued) Three Elbows Figure 7.16 12 ft (3.66 m) min. 60 ft (18.29 m) max. 0 min. 6 ft (1.83 m) max. Maximum horizontal run is 100% of vertical, but can- not exceed 26 ft (7.92 m).[...]
-
Page 33
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 33 * When using SLP pipe, minimum clearances from the vent pipe to combus- tible materials at inside wall firestops are: T op: 2-1/2 in. (64 mm) Bottom: 1/2 in. (13 mm) Sides: 1 in. (25 mm) Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). • DVP heat shield - designed t[...]
-
Page 34
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 34 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP Pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.3). • SLP Pipe only - Frame an opening 9 in. by 9 in. [...]
-
Page 35
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 35 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 requires an at- tic shield constructed of 26 gauge minimum [...]
-
Page 36
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 36 CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. A. T op V ent 9 9 Appliance Preparation Figure 9.2 [...]
-
Page 37
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 37 B. Rear V ent NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. Figure 9.7 Figure 9.8 Figure 9.9 Figure 9.10 Figure 9.1 1 NOTICE: Once the vent cap has been removed it CANNOT be reattached. • Attach the fi rst vent section (it will snap [...]
-
Page 38
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 38 C. Secure and Level the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation. Make sure insulation and[...]
-
Page 39
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 39 A B A B 1 0 10 Inst alling V ent P ipe A. Assemble V ent Sections (DVP only) Attach V ent to the Firebox Assembly Note: The end of the p ipe secti ons with th e lanced tab s will face toward the applianc e. Attach the fi rst pipe section to the starting collar: • Lanced pipe end of [...]
-
Page 40
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 40 B. Assemble V ent Sections (SLP Pipe Only) T o attach the fi rst vent component to the starting collars of the appliance • Attach an SLP-DVP24 adapter to the starting collar of the appliance. • Lock the vent components into place by sliding the pipe section onto the collar . • A[...]
-
Page 41
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 41 D. Assemble Slip Sections W ARNING! Risk of Fire or Asphyxiation! Overlap pipe sections at least 1 1/2 in. (38 mm). Secure slip sections with two screws which must not exceed 1/2 in. (13 mm) in length. Use the pilot holes. Pipe could separate if not properly joined. • Slide the inner[...]
-
Page 42
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 42 Figure 10.9 Securing V ertical Pipe Sections Figure 10.10 Securing Horizontal Pipe Sections E. Secure the V ent Sections • V ertical runs of DVP pipe must be supported every 8 ft. (2.44 m) after the 25 ft. (7.62 m) maximum unsupported rise. • V ertical runs of SLP pipe must be supp[...]
-
Page 43
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 43 G. Install Decorative Ceiling Components (SLP only) A black painted decorative ceiling thimble can be installed on a fl at ceiling through which the vent passes. The ceil- ing thimble is used to cover the fi restop, which is installed according to section 8.C. • Seal the gap betwee[...]
-
Page 44
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 44 Horizontal overhang 12 X 20 in. (508 mm) Lowest Discharge Opening T ermination Cap Roof Pitch is X / 12 V ertical wall H (min.) - Minimum height from roof to lowest discharge opening. 24 in. min. (610 mm) Roof Pitch H (Min.) Ft. Roof Pitch H (Min.) Ft. Flat to 6/12 1.0* Over 1 1/12 to [...]
-
Page 45
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 45 I. Install RF4-8 The RF4-8 may be used in place of the roof fl ashing and storm collar (Sections 10.F . and 10.I.) Pipe must be supported within 12 in. (305 mm) of the roo fl ine using plumbers strapping or an SLP-FS when us- ing the RF4-8 Flashing. Refer to Sect. 8.C. Securing V ent[...]
-
Page 46
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 46 K. Assemble and Install Storm Collar CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp. • Connect both halves of the storm collar with two screws (see Figure 10.23). • Wrap the storm collar arou[...]
-
Page 47
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 47 L. Install Heat Shields and Horizontal T ermi- nation Cap Note: For installation s using black pipe, slide the de corative wall thimble o ver the last v ent pipe before connecting the termina tion cap to t he pipe. When this c onnection has been made, slide the wall thimble up to the i[...]
-
Page 48
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 48 INTERIOR Heat Shield or Extended Heat Shield W all Shield Firestop Heat Shield 1-1/2 in. (38 mm) min. overlap SHEA THING V ent depth from back of appliance to outside surface of exterior wall (see chart below) Slip Section can be extended Inner V ent Outer V ent EXTERIOR Note: W h e n [...]
-
Page 49
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 49 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a quali fi ed technician using Hearth & Home T echnologies specified and approved parts. B. Gas Pressure • Optimum appliance performance requires proper input p[...]
-
Page 50
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 50 Red or Black Button Figure 12.1 Ignitor Button B. Standing Pilot Ignition System Wiring • The standing pilot ignition system wiring does not require a 1 10 V AC supply to operate. • A 1 10 V AC junction box MUST be installed for use with a fan or remote control. See Figure 12.3 for[...]
-
Page 51
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 51 Pilot Ignitor T o Burner Gas Inlet Inlet T ap ORG SIL VER TO PILOT TH TP TH/TP Thermopile WHT RED BRN Manifold (outlet) Pressure T ap Thermocouple Copper T ubing Push Button Ignitor Pilot Adjustment Cap W all Switch (or thermostat if heater-listed) Manifold Pressure Adjustment Fitting [...]
-
Page 52
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 52 G. W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.5): • The power supply for the appliance must be brought into a switch box. • The power can then be supplied from the switch box to the appliance usi[...]
-
Page 53
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 53 1 in. (25 mm) min. to perpendicular wall A 3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall B Mantel Leg or Perpendicular W all T op of Appliance Drywall A B Measured from top of hood (in inches) 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 5 5-1/2 6-1/4 7 7-3/4 8-1/2 9-[...]
-
Page 54
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 54 0 in. 0 in. 0 in. Finish wall material may be combustible - T op and Sides High T emperature Sealant (300° F/149° C min.) T op and Side Seal Joint B. Facing Material • Cover the metal front faces with non-combustible materi- als only . • Facing and/or fi nishing materials must n[...]
-
Page 55
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 55 1 4 14 Appliance Setup A. Remove the Packaging Remove the shrink fi lm, corrugated top cap, bottom cap and column protectors from the appliance. The appliance should look as shown in Figure 14.1. B. Open Front Screen Assembly • Open the fl ap in the upper left hand corner of the sc[...]
-
Page 56
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 56 Rockwool Lava Rock & V ermiculite Figure 14.5 Placement of Rockwool, Lava Rock and V ermiculite G. Place the Rockwool W ARNING! Risk of Explosion! Follow rockwool place- ment instructions. DO NOT place rockwool directly over burner ports. Replace rockwool material annually . Improp[...]
-
Page 57
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 57 L. Install Hood • Locate the four screws just inside the upper section of the appliance. • Slide the hood into position uncer the screw heads. • T ighten the four screws. See Figure 14.9. K. Unpackage the Hood & Floor Cover Remove the hood, fl oor cover and protective cardbo[...]
-
Page 58
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 58 Latches (both bottom and top) Glass Assembly Figure 14.1 1 Glass Assembly M. Install Floor Cover Install the fl oor cover as shown in Figure 14.10. N. Fixed Glass Assembly Removing Fixed Glass Assembly W ARNING! Risk of Asphyxiation! Handle fi xed glass assembly with care. Inspect th[...]
-
Page 59
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 59 P . Air Shutter Setting Air shutter setting should be adjusted by a quali fi ed in- staller at the time of installation. • The air shutter is set at the factory for minimum vertical vent run. • Adjust air shutter for longer vertical runs. See Figure 14.14. • T urn the thumbscrew[...]
-
Page 60
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 60 A. Standing Pilot Ignition System 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed technician in the diagnosi[...]
-
Page 61
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 61 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. (Continued) C. Failed valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the thermopile terminals. The millivolt meter should read greater than [...]
-
Page 62
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 62 B. Intelli fi re Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light. The ignitor/module makes noise, but no spark. A. Incorrect wiring. V erify “S” wire (white) for sensor and “I” wire (orange) for ignitor are connected to correct terminals on modu[...]
-
Page 63
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 63 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but continues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occurred.) A. A shorted[...]
-
Page 64
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 64 1 6 16 Reference Materials Electrical Access Alternative Gas Access 1-3/4 in. (44 mm) 34-1/2 in. (876 mm) 1-1/2 in. (38 mm) 15-3/4 in. (400 mm) 8 in. (203 mm) 2-3/8 in. (60 mm) 31-1/2 in. (800 mm) 34 in. (864 mm) A B 23-1/2 in. (597 mm) 6-1/2 in. (165 mm) C 19-1/8 in. (486 mm) 1 1-5/8i[...]
-
Page 65
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 65 B. V ent Components Diagrams Figure 16.2 DVP V ent Components Effective Height/Length DVP Pipe (see chart) Pi p e inches mm DVP4 4 10 2 DVP6 6 15 2 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 1219 D V P 6 A 3-6 7 6-1 5 2 DVP12A 3 - 12 76 - 305 DVP12MI 3 - 12 76 - 305 DVP24MI 3 - 24[...]
-
Page 66
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 66 B. V ent Components Diagrams ( continued ) Figure 16.3 DVP V ent Components 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (698 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK T rap Cap Brick Extension 13-3/[...]
-
Page 67
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 67 B. V ent Components Diagrams ( continued ) Figure 16.4 DVP V ent Components DVP-TB1 Basement V ent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7 - 3/8 i n. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 10-1/2 in. (267 mm) 3-7/8 in. (98 mm) DVP-TV V ertical T ermination Cap PVK-80 (For use wit[...]
-
Page 68
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 68 B. V ent Components Diagrams ( continued ) Figure 16.5 DVP V ent Components DVP-TRAP1 DVP-TRAP2 DVP-HPC1 DVP-HPC2 DVP-TRAPK1 DVP-TRAPK2 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a mini[...]
-
Page 69
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 69 B. V ent Components Diagrams (continued) Figure 16.6 DVP V ent Components 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) DVP-HRC-SS 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 5-1/2 in. 140 mm 8-3/8 in. 213 mm DVP-HRC-ZC-SS Fillers[...]
-
Page 70
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 70 Figure 16.7 SLP Series V ent Components 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 9-7/8 in. 251 mm 6-1/2 in. 165 mm 9-1/4 in. 235 mm SLP-45 - 45° Elbow SLP-90ST - 90° Elbow Effective Height/ Length SLP-Pipe SLP-HVS Horizontal Pi[...]
-
Page 71
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 71 B. V ent Components Diagrams (continued) Figure 16.8 SLP Series V ent Components SLK-SNKD Snorkel T ermination Cap SLP-TVHW V ertical T ermination Cap PVK-80 Power V ent SLP-TRAP1 Horizontal T ermination Cap DVP-FBHT Horizontal T ermination Cap SLP-CCS-BK Cathedral Ceiling Sup- port Bo[...]
-
Page 72
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 72 C. Service Parts NDV3630 & NDV3630I Service Parts IMPORT ANT : THIS IS DA TED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stoc[...]
-
Page 73
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 73 NDV3630 & NDV3630I Service Parts 1 2 3 4 5 6 7 8 10 9 1 2 3 4 5 6 7 8 9 10 11 12 Standing Pilot V alve IPI V alve IMPORT ANT : THIS IS DA TED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts liste[...]
-
Page 74
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 74 13 11 12 9 17 18 19 21 22 20 10 23 5 6 7 8 16 14 15 3 1 4 2 IMPORT ANT : THIS IS DA TED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer [...]
-
Page 75
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 75 NDV3933 & NDV3933I Service Parts 1 2 3 4 5 6 7 8 10 9 1 2 3 4 5 6 7 8 9 10 11 12 IMPORT ANT : THIS IS DA TED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered f[...]
-
Page 76
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 76 NDV4236 & NDV4236I Service Parts IMPORT ANT : THIS IS DA TED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM[...]
-
Page 77
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 77 NDV4236 & NDV4236I Service Parts 1 2 3 4 5 6 7 8 10 9 1 2 3 4 5 6 7 8 9 10 11 12 IMPORT ANT : THIS IS DA TED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered f[...]
-
Page 78
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 78 13 11 12 10 9 17 18 21 22 20 19 23 5 6 7 8 16 14 15 3 1 4 2 NDV4842 & NDV4842I Service Parts IMPORT ANT : THIS IS DA TED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may [...]
-
Page 79
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 79 NDV4842 & NDV4842I Service Parts 1 2 3 4 5 6 7 8 10 9 IMPORT ANT : THIS IS DA TED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . [...]
-
Page 80
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 80 D. Optional Components Model # Description NDV3630 T op/rear direct vent standing pilot, natural gas, 36” framing width, 30” viewing glass NDV3630L T op/rear direct vent standing pilot, L.P . gas, 36” framing width, 30” viewing glass NDV3630I T op/rear direct vent, natural gas,[...]
-
Page 81
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 81 Model # Description NDV4236 T op/rear direct vent standing pilot, natural gas, 42” framing width, 36” viewing glass NDV4236L T op/rear direct vent standing pilot, L.P . gas, 42” framing width, 36” viewing glass NDV4236I T op/rear direct vent, natural gas, Intelli fi re ignitio[...]
-
Page 82
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 82 This page intentionally left blank.[...]
-
Page 83
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 83 This page intentionally left blank.[...]
-
Page 84
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 84 Heatilator , a brand of Hearth & Home T echnologies Inc. 1915 W . Saunders St., Mt. Pleasant, IA 52641 E. Contact Information Please contact your Heatilator dealer with any questions or concerns. For the location of your nearest Heatilator dealer , please visit www .heatilator .com[...]