Heat & Glo LifeStyle 6000CMOD-IPI manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Heat & Glo LifeStyle 6000CMOD-IPI, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Heat & Glo LifeStyle 6000CMOD-IPI one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Heat & Glo LifeStyle 6000CMOD-IPI. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Heat & Glo LifeStyle 6000CMOD-IPI should contain:
- informations concerning technical data of Heat & Glo LifeStyle 6000CMOD-IPI
- name of the manufacturer and a year of construction of the Heat & Glo LifeStyle 6000CMOD-IPI item
- rules of operation, control and maintenance of the Heat & Glo LifeStyle 6000CMOD-IPI item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Heat & Glo LifeStyle 6000CMOD-IPI alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Heat & Glo LifeStyle 6000CMOD-IPI, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Heat & Glo LifeStyle service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Heat & Glo LifeStyle 6000CMOD-IPI.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Heat & Glo LifeStyle 6000CMOD-IPI item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance. - DO NOT touch any electrical switch. DO NOT use any phone in your building. - I[...]

  • Page 2

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: _____________________ Dealership purchased from: ____[...]

  • Page 3

    3 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous si[...]

  • Page 4

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 4  = Contains updated information. 13 Finishing A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 47 B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 C. Finish and Sealing Joints . . . . . . . . . . . . . [...]

  • Page 5

    5 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 B. Limited Lifetime W arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal an[...]

  • Page 6

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 6 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS:  7KLVZDUUDQWRQOFRYHUV++7DSSOLDQFHVWKDWDUHSXUFKDVHGW KURXJKDQ++7 DXWKRUL]HGGHDOHURUGLVWULEXWRU  $ OLVWRI ++7DXWKRUL]HGGHDOHUVLVDYDLODEOHR[...]

  • Page 7

    7 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 C. BTU Speci fi cations MODELS: 6000CMOD-IPI, 8000CMOD-IPI LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Direct Vent Gas Appliance Heater STANDARD: ANSI Z21.50b-2009 • CSA 2.22b-2009 This product is listed to ANSI standards for “V ented Gas Appliance Heaters[...]

  • Page 8

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and[...]

  • Page 9

    9 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury . DECORA TIVE DOORS (NOT S[...]

  • Page 10

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects. Figure[...]

  • Page 11

    11 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Nine Hour Safety Shutdown Feature This appliance has a safety feature that automatically shuts down the fi replace after 9 hours of continuous operation without receiving a command from the RC300 remote. J. Before Lighting Fireplace Before operating this fi replace for[...]

  • Page 12

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 12 K. Lighting Instructions (IPI) 1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. 2. Wait fi ve (5) minutes to clear out any gas. Then smell for gas, including near the fl oor. If you sme[...]

  • Page 13

    13 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly . See Section 14.G. • Clean fi xed glass assembly . See Section 3. •[...]

  • Page 14

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 14 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slamming glass • Avoid ab[...]

  • Page 15

    15 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 • Con fi rm there is no damage to glass or glass frame. Replace as necessary . • V erify that fi xed glass assembly is properly retained and attachment components are intact and not damaged. Replace as necessary . Interior Ceramic Glass Panel Cleaning Frequency: Se[...]

  • Page 16

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 16 Figure 3.3 Glass Panel Removal C. Glass Refractory , Base Pan, Burner and V alve Assembly Removal It may become necessary to remove the glass panels, base pan, burner and valve assembly . This task should be performed by a quali fi ed service technician. Figure 3.4 Base[...]

  • Page 17

    17 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Figure 3.6 V alve Assembly Removal Appearance of valve components may vary . 8000CMOD-IPI (NG) 8000CMOD-IPI (LP) Figure 3.8 V alve Assembly Removal 6000CMOD-IPI (NG) 6000CMOD-IPI (LP) Figure 3.7 V alve Assembly Removal D. Burner Identi fi cation[...]

  • Page 18

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 18 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.1 T ypical System CEILING FIRESTOP ON[...]

  • Page 19

    19 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required. Installa[...]

  • Page 20

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 20 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). W ARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for [...]

  • Page 21

    21 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: T reatment of ceiling fi restops and wall shield fi restops [...]

  • Page 22

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 22 D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board, et[...]

  • Page 23

    23 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* Over 7/12 to 8/12 .......................................[...]

  • Page 24

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 24 Figure 6.3 Minimum Clearances for T ermination O N P R Q X = AIR SUPPL Y INLET A = 12 inches................. clearances above grade, veranda, porch, deck or balcony B = 12 inches................. clearance to window or door that may be opened, or to permanently closed w[...]

  • Page 25

    25 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP or SLP venting systems. Refer to Sec- tion 16B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufacturers. The pipe is tested t[...]

  • Page 26

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 26 H 1 V 1 Figure 7.3 T op V ent - Horizontal T ermination T op V ent - Horizontal T ermination One Elbow Note: For corner installations: A 6 inch (152 mm) section of straight pipe may need to be attached to the appliance before a 90º elbow , to allow the vent pipe to clea[...]

  • Page 27

    27 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 INST ALLED HORIZONT ALL Y H 1 H 2 V 1 Figure 7.4 T wo Elbows Note: For corner installations: A 6 inch (152 mm) section of straight pipe may need to be attached to the appliance before a 90º elbow , to allow the vent pipe to clear the top standoffs. 6000CMOD-IPI V 1 Mini[...]

  • Page 28

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 28 Figure 7.5 T op V ent - Horizontal T ermination - (continued) Three Elbows H 2 H 1 V 2 V 1 V 1 Min. H 1 Max. V 2 Min. H 2 Max. Elbow only 2 ft. 610 mm 0 in. 0 mm 1 ft. 305 mm 6 in. 152 mm 3 ft 914 mm 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 6 ft. 1.8 m 1 ft. 305 mm 6 ft. 1[...]

  • Page 29

    29 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 FLUE RESTRICTOR T op V ent - V ertical T ermination No Elbow Figure 7.6 Note: If installing a vertical vent/ termination off the top of the appli- ance, the fl ue restrictor should be used. See Figure 7.9. V 1 V 1 = 40 ft. Max. (12.4 m) V 1 = 3 ft. Min. (914 mm) Figure [...]

  • Page 30

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 30 H 1 V 1 V 2 T op V ent - V ertical T ermination (continued) Figure 7.1 1 T wo Elbows Figure 7.10 4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Figure 7.10). 5. Reinstall the Exhaust Shield. 3. Match the amount of vertical[...]

  • Page 31

    31 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Figure 7.12 T op V ent - V ertical T ermination - (continued) Three Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 V 2 V 1 H 1 + H 2 V 2 V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft. 305 mm * * * 1 ft. 305 mm 6 in. 152 mm 2 ft. 610 mm * * * 2 ft. 610 mm 1 ft. 305 mm[...]

  • Page 32

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 32 A* B 10 in. 12 in. A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops • Between wall shield fi restops • Around vent system Failure to keep in[...]

  • Page 33

    33 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.3). • SLP pipe only - Frame opening 9 i[...]

  • Page 34

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 34 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 and NFPA 54 requires an attic shield constru[...]

  • Page 35

    35 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 9 9 Appliance Preparation CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. A. T op V ent Figure 9.1 Cut the seal cap strap across the rectangles next to the disk. For rear ven[...]

  • Page 36

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 36 Figure 9.7 Non-combustible Board B. Installing the Non-combustible Board The factory supplied non-combustible board spans the distance from the top of the fi replace to the center of the framing header . This board must be used. See Figure 9.7. HEADER HEADER C. Securing[...]

  • Page 37

    37 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 1 0 10 Inst alling V ent Pipe (D VP and SLP P ip e ) A. Assemble V ent Sections (DVP Pipe Only) Attach V ent to the Firebox Assembly Note: The end of the pipe sec tions wi t h the lanced tabs w ill face toward the appliance. Attach the fi rst pipe section to the startin[...]

  • Page 38

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 38 B. Assemble V ent Sections (SLP Pipe Only) T o attach the fi rst vent component to the starting collars of the appliance: • Attach a DVP-2SL or DVP-SLP24 adapter to the starting collar of the appliance. • Lock the vent components into place by sliding the pipe secti[...]

  • Page 39

    39 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 120º Figure 10.8 Securing V ertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble V ent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown in Figure 10.1 1. • Pull carefully [...]

  • Page 40

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 40 F . Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a fl at ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the fi restop. • Seal the gap between the vent pipe and fi restop u[...]

  • Page 41

    41 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 G. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through the roof as shown in Figure 10.15. Roof[...]

  • Page 42

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 42 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.23 Figure 10.23 TERMINA TION CAP I. Install V ertical T ermination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while placing the outer collar of [...]

  • Page 43

    43 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Figure 10.25 Venting through the wall INTERIOR HEA T SHIELD OR EXTENDED HEA T SHIELD W ALL SHIELD FIRESTOP HEA T SHIELD 1-1/2 IN. (38 MM) MIN. OVERLAP SHEA THING VENT DEPTH FROM BACK OF APPLIANCE T O OUTSIDE SURF ACE OF EXTERIOR WALL (SEE CHART BELOW) SLIP SECTION CAN BE[...]

  • Page 44

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 44 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts. B. Gas Pressure • Optimum appliance performance [...]

  • Page 45

    45 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.1. • Wire the applian[...]

  • Page 46

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 46 F . W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.3): • The power supply for the appliance must be brought into a switch box. • The power can then be supplied from the switch box to t[...]

  • Page 47

    47 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 1 3 13 Fi nishing A. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing closer than the minimums list- ed must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.) Fi[...]

  • Page 48

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 48 B. Facing Material • Metal front faces may be covered with non-combustible materials only . • Facing and/or fi nishing materials must not interfere with air fl ow through louvers, operation of louvers or doors, or access for service. • Facing and/or fi nishing m[...]

  • Page 49

    49 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 D. Door Selection Only doors certi fi ed for use with this appliance model may be used. Contact your dealer for a list of doors that may be used. The CMOD door can not be used if the appliance is installed directly on the fl oor . See Figure 13.6 and 13.7. WA L L WA L [...]

  • Page 50

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 50 Figure 13.8 Finishing Material 1 Inch Thick or Less DOOR 1 in. MAX. FINISHING MA TERIAL (TOP EDGE) Finishing materials 1 inch maximum thick. Stop fi nishing material fl ush with opening. NON-COMBUSTIBLE FINISHING MA TERIAL Finishing Material: 1 Inch Thick or Less - Ove[...]

  • Page 51

    51 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 DOOR FINISHING MA TERIAL FINISHING MA TERIAL C (Includes 1/8 in. opening each side of door) A (Outside door width) Finishing Material Thickness Greater than 1 Inch B = T op of door to bottom of fi replace. D = Bottom of Finishing Material to Bottom of Fireplace A (Outsi[...]

  • Page 52

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 52 A. Remove Fixed Glass Assembly See Section 14.G. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the contro[...]

  • Page 53

    53 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 F . Media Placement W ARNING! Risk of Explosion! Follow media placement instructions. Improperly placed media interfere with proper burner operation. Fireplace will not function properly . Delayed ignition may occur . W ARNING! Choking Hazard! Keep media out of reach of [...]

  • Page 54

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 54 Figure 14.7 Placement of Media NO MEDIA ON PILOT OPENING (WHITE AREA) BURNER NO MEDIA ON PILOT OPENING (WHITE AREA) BURNER Figure 14.8 Placement of Media Figure 14.9 Proper Placement of Media[...]

  • Page 55

    55 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Figure 14.8 Air Shutter Figure 14.7 Fixed Glass Assembly G. Fixed Glass Assembly W ARNING! Risk of Asphyxiation! Handle fi xed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches. • DO NOT strike,[...]

  • Page 56

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 56 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed service technician in the diagnosis of a prob[...]

  • Page 57

    57 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 T roubleshooting (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occurred.) A. A shorte[...]

  • Page 58

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 58 1 6 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only . For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance Dimensions-6000 Models A B C D E FRONT VIEW TOP VIEW LEFT SIDE R[...]

  • Page 59

    59 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Figure 16.2 Appliance Dimensions-8000 Models Location Inches Millimeters J 21 533 K 1 1-1 1/16 297 L 35-1/2 901 M 17-3/4 451 N 8-1/2 216 O 2-7/8 73 P 8-1/2 216 Q1 2 5 R 42-7/8 1089 Location Inches Millimeters A 48 1219 B 43-1/8 1096 C 35-1/2 902 D 36-5/8 930 E 2-3/8 60 F[...]

  • Page 60

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 60 B. V ent Components Diagrams Figure 16.2 DVP vent components Pipe Effective Length Inches Millimeters DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 DVP12MI 3 to 12 76 to 305 DVP24MI 3 to 24 76 t[...]

  • Page 61

    61 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be u[...]

  • Page 62

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 62 13-1/4 in. (337 mm) 24-5/8 in. (625 mm) 27-1/2 in. (699 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (337 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extension 13-3/4 in. (349 mm) 5 in. (127 mm) 13-3/4 in. (349 mm) Cap Shield [...]

  • Page 63

    63 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW VerticalTermination Cap (Highwind) PVK-80 (Not compatible with Intellifire P[...]

  • Page 64

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 64 B. V ent Components Diagrams (continued) DVP-HRC-SS DVP-HRC-ZC-SS HORIZONT AL TERMINA TION CAP 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 5-1/2 in. 140 mm 8-3/8 in. 213[...]

  • Page 65

    65 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 B. V ent Components Diagrams (continued) Figure 16.7 SLP Series V ent Components 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 9-7/8 in. 251 mm 6-1/2 in. 165 mm 9-1/4 in. 235 mm SLP45 45° Elbow SLP90 90° Elbow Effecti[...]

  • Page 66

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 66 B. V ent Components Diagrams (continued) Figure 16.8 SLP Series V ent Components SLK-SNKD Snorkel T ermination Cap SLP-TVHW V ertical T ermination Cap SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-DCF-BK Ceiling Firestop Black SLP-WT -BK W all Thimble-Black DVP-2SL [...]

  • Page 67

    67 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 C. Service Parts Beginning Manufacturing Date: Aug 2010 Ending Manufacturing Date:______ 6000CMOD-IPI 36” Modern Direct V ent Fireplace IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number[...]

  • Page 68

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 68 C. Service Parts Beginning Manufacturing Date: Aug 2010 Ending Manufacturing Date:______ 8000CMOD-IPI 42” Modern Direct V ent Fireplace IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number[...]

  • Page 69

    69 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 C. Service Parts Beginning Manufacturing Date: Aug 2009 Ending Manufacturing Date: ______ 6000CMOD-IPI, 8000CMOD-IPI IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . [...]

  • Page 70

    Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 70 Service Parts List 6000CMOD-IPI, 8000CMOD-IPI IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized deale[...]

  • Page 71

    71 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer , please visit www .heatnglo.com. - NOTES - ___________________________________________________________________________[...]