A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Heat & Glo LifeStyle 6000GL-IPILP-R, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Heat & Glo LifeStyle 6000GL-IPILP-R one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Heat & Glo LifeStyle 6000GL-IPILP-R. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Heat & Glo LifeStyle 6000GL-IPILP-R should contain:
- informations concerning technical data of Heat & Glo LifeStyle 6000GL-IPILP-R
- name of the manufacturer and a year of construction of the Heat & Glo LifeStyle 6000GL-IPILP-R item
- rules of operation, control and maintenance of the Heat & Glo LifeStyle 6000GL-IPILP-R item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Heat & Glo LifeStyle 6000GL-IPILP-R alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Heat & Glo LifeStyle 6000GL-IPILP-R, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Heat & Glo LifeStyle service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Heat & Glo LifeStyle 6000GL-IPILP-R.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Heat & Glo LifeStyle 6000GL-IPILP-R item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 1 Models: 6000GL-IPI-S 6000GL-IPI-R 6000GL-IPILP-S 6000GL-IPILP-R • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance. - DO NOT touch a[...]
-
Page 2
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: _____________________ Dealership purchased from: ____[...]
-
Page 3
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous si[...]
-
Page 4
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 4 Î = Contains updated information. 13 Finishing A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 50 B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 C. Doors . . . . . . . . . . . . . . . . . . . . . . . .[...]
-
Page 5
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 5 B. Limited Lifetime W arranty Î[...]
-
Page 6
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 6 B. Limited Lifetime W arranty (continued) Î[...]
-
Page 7
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 7 C. BTU Speci fi cations This product is listed to ANSI standards for “V ented Gas Appliance Heaters” and applicable sections of “Gas Burn- ing Heating Appliances for Manufactured Homes and Recreational V ehicles”, and “Gas Fired Appliances for Use at High Altit[...]
-
Page 8
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and[...]
-
Page 9
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 9 Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury . DECORA TIVE DOORS (NOT S[...]
-
Page 10
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects. Figure[...]
-
Page 11
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 1 1 I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer . T o prolong battery life, remove them when using the transformer . 1. Turn off all electric power to the appliance. 2. This appliance [...]
-
Page 12
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 12 J. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly . See Section 14.H. • Clean fi xed glass ass[...]
-
Page 13
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 13 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slamming glass • Avoid ab[...]
-
Page 14
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 14 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc. • V erify termination cap clearance to subsequent [...]
-
Page 15
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 15 Figure 3.1 IPI Pilot Flame Patterns[...]
-
Page 16
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 16 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.1 T ypical System CEILING FIRESTOP ON[...]
-
Page 17
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 17 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required. Installa[...]
-
Page 18
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 18 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). W ARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for [...]
-
Page 19
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 19 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: T reatment of ceiling fi restops and wall shield fi restops [...]
-
Page 20
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 20 D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board, et[...]
-
Page 21
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 21 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* Over 7/12 to 8/12 .......................................[...]
-
Page 22
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 22 O N P R Q V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 6.3 Minimum Clearances for T ermination A = 12 inches................. clearances above grade, ver anda, porch, deck or balcony B = 12 inches................. clearances to wi[...]
-
Page 23
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 23 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP or SLP venting systems. Refer to Sec- tion 16.B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufacturers. The pipe is tested [...]
-
Page 24
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 24 INST ALLED HORIZONT ALL Y H 1 H 2 V 1 H 1 V 1 Figure 7.3 Figure 7.4 T op V ent - Horizontal T ermination T op V ent - Horizontal T ermination One Elbow T wo Elbows Note: For corner installations: A 6 inch (152 mm) section of straight pipe may need to be attached to the a[...]
-
Page 25
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 25 Figure 7.5 T op V ent - Horizontal T ermination - (continued) Three Elbows H 2 H 1 V 2 V 1 V 1 Min. H 1 Max. V 2 Min. H 2 Max. Elbow only 2 ft. 610 mm 0 in. 0 mm 1 ft. 305 mm 6 in. 152 mm 3 ft 914 mm 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 6 ft. 1.8 m 1 ft. 305 mm 6 ft. 1[...]
-
Page 26
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 26 T op V ent - V ertical T ermination No Elbow Figure 7.6 Note: If installing a vertical vent/ termination off the top of the ap- pliance, the fl ue restrictor should be used. V 1 V 1 = 40 ft. Max. (12.4 m) V 1 = 3 ft. Min. (914 mm) Figure 7.8 Flue Restrictor 2. Break the[...]
-
Page 27
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 27 H 1 V 1 V 2 T op V ent - V ertical T ermination (continued) Figure 7.1 1 T wo Elbows Figure 7.10 4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Figure 7.10). 5. Reinstall the Exhaust Shield. 3. Match the amount of vertical[...]
-
Page 28
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 28 Figure 7.12 T op V ent - V ertical T ermination - (continued) Three Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 V 2 V 1 H 1 + H 2 V 2 V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft. 305 mm * * * 1 ft. 305 mm 6 in. 152 mm 2 ft. 610 mm * * * 2 ft. 610 mm 1 ft. 305 mm[...]
-
Page 29
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 29 Rear V ent - Horizontal T ermination Figure 7.13 Figure 7.14 No Elbow One 45º Elbow H 1 H 1 H 1 = 16 in. (406 mm) Maximum Do not use a 45º elbow in corner installations. Use two 90º elbows instead.[...]
-
Page 30
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 30 INSTALLED HORIZONTALLY H 3 H 1 H 2 V 1 Rear V ent - Horizontal T ermination - (continued) T wo Elbows Figure 7.15 Figure 7.16 Three Elbows H 1 H 2 V 1 H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 1 ft. 305 mm Back to Back 90º Elbows 1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 [...]
-
Page 31
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 31 Rear V ent - V ertical T ermination One Elbow Figure 7.17 T wo Elbows Figure 7.18 H 1 V 1 INST ALL ED HORIZONT ALL Y H 1 H 2 V 2 V 1 Minimum H 1 Maximum 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 3 ft. 914 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft. 914 mm 7 ft. 2.1 m 4 ft. 1.2 m 8 ft[...]
-
Page 32
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 32 Rear V ent - V ertical T ermination - (continued) Three Elbows Figure 7.19 Three Elbows Figure 7.20 INST ALLED HORIZONT ALL Y H 3 H 1 H 2 V 1 V 2 V 1 H 2 H 1 H 1 H 2 H 3 V 1 Minimum H 1 + H 2 + H 3 Maximum *** 8 ft. 2.4 m 6 ft. 1.8 m *** 9 ft. 2.7 m 7 ft. 2.1 m *** 10 ft[...]
-
Page 33
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 33 A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops • Between wall shield fi restops • Around vent system Failure to keep insulation or other m[...]
-
Page 34
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 34 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.3). • SLP pipe only - Frame opening 9 i[...]
-
Page 35
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 35 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 and NFPA 54 requires an attic shield constru[...]
-
Page 36
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 36 A. T op V ent CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. 9 9 Appliance Pr[...]
-
Page 37
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 37 B. Rear V ent CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. Figure 9.7 T o a[...]
-
Page 38
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 38 D. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation. Make[...]
-
Page 39
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 39 1 0 10 Inst alli ng V ent Pi pe (D VP and SLP P ipe ) A. Assemble V ent Sections (DVP Pipe Only) Attach V ent to the Firebox Assembly Note: The end of t he pipe secti ons with the lanc ed tabs wi ll face toward the applianc e. Attach the fi rst pipe section to the start[...]
-
Page 40
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 40 B. Assemble V ent Sections (SLP Pipe Only) T o attach the fi rst vent component to the starting collars of the appliance: • Attach a DVP-2SL or DVP-SLP24 adapter to the starting collar of the appliance. • Lock the vent components into place by sliding the pipe secti[...]
-
Page 41
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 41 120º Figure 10.8 Securing V ertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble V ent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown in Figure 10.1 1. • Pull carefully [...]
-
Page 42
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 42 F . Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a fl at ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the fi restop. • Seal the gap between the vent pipe and fi restop u[...]
-
Page 43
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 43 G. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through the roof as shown in Figure 10.15. Roof[...]
-
Page 44
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 44 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.18 Figure 10.18 TERMINA TION CAP I. Install V ertical T ermination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while placing the outer collar of [...]
-
Page 45
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 45 Figure 10.20 Venting through the wall INTERIOR HEA T SHIELD OR EXTENDED HEA T SHIELD W ALL SHIELD FIRESTOP HEA T SHIELD 1-1/2 IN. (38 MM) MIN. OVERLAP SHEA THING VENT DEPTH FROM BACK OF APPLIANCE T O OUTSIDE SURF ACE OF EXTERIOR WA LL (SEE CHART BELOW) SLIP SECTION CAN B[...]
-
Page 46
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 46 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts. B. Gas Pressure • Optimum appliance performance [...]
-
Page 47
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 47 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.1. • Wire the applian[...]
-
Page 48
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 48 D. Electrical Service and Repair W ARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing. Figure 12.1 IntelliFire Pilot Ignition (IPI) Wi[...]
-
Page 49
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 49 F . W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.3): • The power supply for the appliance must be brought into a switch box. • The power can then be supplied from the switch box to t[...]
-
Page 50
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 50 1 3 13 Fi nishing A. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing closer than the minimums list- ed must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.). F[...]
-
Page 51
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 51 C. Doors Only doors certi fi ed for use with this appliance model may be used. Contact your dealer for a list of doors that may be used. Once you have determined what kind of door and fi nishing material is going to be used on the fi replace, you may use the table bel[...]
-
Page 52
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 52 A. Remove Fixed Glass Assembly See Section 14.H. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the contro[...]
-
Page 53
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 53 F . Ember Placement W ARNING! Risk of Explosion! Follow ember placement instructions in manual. DO NOT place embers directly over burner ports. Replace ember material annually . Improperly placed embers interfere with proper burner operation. Ember material is shipped wi[...]
-
Page 54
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 54 G. Install the Log Assembly Log Assembly: LOGS-6000GL STEP 2. Place the metal grate on top of the burner . Position the legs of the grate into the forward set of indentations in the burner top. The grate should not cover any ports in the burner . STEP 1. CAUTION: Logs ar[...]
-
Page 55
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 55 Figure 14.1 1 T op View STEP 5. Log #3 (SR V2102-105): Place log #3 on top of the burner surface in front of the hump. The bottom of the log is contoured to match some of the burner surface features. Slide it back against the hump. The “V” shaped notch in the front b[...]
-
Page 56
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 56 K. Air Shutter Setting Air shutter settings should be adjusted by a quali fi ed ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 14.19. • Loos[...]
-
Page 57
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 57 A. IntelliFire Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light. The ignitor/module makes noise, but no spark. A. Incorrect wiring. V erify “S” wire (white) for sensor and “I” wire (orange) for ignitor are connected to correct termi[...]
-
Page 58
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 58 IntelliFire Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occurred.[...]
-
Page 59
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 59 1 6 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only . For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance Dimensions A D B C H ELECTRICAL ACC ESS G F E GAS LINE ACC ESS N[...]
-
Page 60
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 60 B. V ent Components Diagrams Figure 16.2 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in. (337 mm) 1/2 in. TYP DVP90ST (90° Elbow) 10 in. (254 mm) 10 in. (254 mm) 1 i[...]
-
Page 61
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 61 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be u[...]
-
Page 62
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 62 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extension 13-3/4 in. (349 mm) 5 in. (127 mm) 13-3/4 in. (349 mm) Cap Shield [...]
-
Page 63
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 63 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW VerticalTermination Cap (Highwind) PVK-80 (For use with IPI and DSI applianc[...]
-
Page 64
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 64 B. V ent Components Diagrams (continued) DVP-HRC-SS DVP-HRC-ZC-SS HORIZONT AL TERMINA TION CAP 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 5-1/2 in. 140 mm 8-3/8 in. 213[...]
-
Page 65
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 65 B. V ent Components Diagrams (continued) Figure 16.7 SLP Series V ent Components Effective Height/Length Pipe inches mm SLP4 4 102 SLP6 6 152 SLP12 12 305 SLP24 24 610 SLP36 36 914 SLP48 48 1219 SLP6A 2 - 6 51 - 152 SLP12A 2 - 12 51 - 305 8-3/4 in. 222 mm 6-1/2 in. 165 m[...]
-
Page 66
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 66 B. V ent Components Diagrams (continued) Figure 16.8 SLP Series V ent Components SLP-SNKD Snorkel T ermination Cap SLP-TVHW Ve r t i c a l T ermination Cap SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-DCF-BK Ceiling Firestop Black SLP-WT -BK W all Thimble-Black DVP[...]
-
Page 67
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev . R • 6/09 70 D. Contact Information - NOTES - ________________________________________________________________________________ ________________________________________________________________________________ ____________________________________________________________________________[...]