Heat & Glo LifeStyle 6000TV-OAK-IPI manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Heat & Glo LifeStyle 6000TV-OAK-IPI, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Heat & Glo LifeStyle 6000TV-OAK-IPI one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Heat & Glo LifeStyle 6000TV-OAK-IPI. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Heat & Glo LifeStyle 6000TV-OAK-IPI should contain:
- informations concerning technical data of Heat & Glo LifeStyle 6000TV-OAK-IPI
- name of the manufacturer and a year of construction of the Heat & Glo LifeStyle 6000TV-OAK-IPI item
- rules of operation, control and maintenance of the Heat & Glo LifeStyle 6000TV-OAK-IPI item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Heat & Glo LifeStyle 6000TV-OAK-IPI alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Heat & Glo LifeStyle 6000TV-OAK-IPI, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Heat & Glo LifeStyle service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Heat & Glo LifeStyle 6000TV-OAK-IPI.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Heat & Glo LifeStyle 6000TV-OAK-IPI item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 1 Model: 6000TV -OAK 6000TV -OAK-IPI Underwriters Laboratories Listed In the Commonwealth of Massachusetts: • installation must be performed by a licensed plumber or gas fitter; • a CO detector shall be installed in the room where the appliance is installed. - Do not[...]

  • Page 2

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide . NO OTHER vent systems or component s MA Y BE USED . This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be at[...]

  • Page 3

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 3 TABLE OF CONTENTS Safety and W arning Information . ............................................... 2 Service Parts Lists . .................................................................... 4 Section 1: Approvals and Codes . .........................................[...]

  • Page 4

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 4 Part number list on following page. 6 Log Set Assembly 5 4 2 1 3 11 10 12 8 7 9 13 (NG , LP) Exploded Parts Diagram Service Parts Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: ______ 6000TV -OAK, 6000TV -OAK-IPI[...]

  • Page 5

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 5 Service Parts List ITE M CO M MO N P A RTS SERI A L # PAR T N U MB E R 1B u r n e r N G , L P SRV383-338A 2 G lass Door Assembl y GL A -6 TROC 3 S u rro u nd PR E 002324 021 POST 002324021 385-130 2026-10 8 4H o o d SR V60-143-BK 5 Log Gr ate 383-360A 6 O ak Log Set As[...]

  • Page 6

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 6 (NG , LP) Exploded Parts Diagram Service Parts Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: ______ Intermittent Pilot Ignition V alve Assembly IT E M DES CRI PT I O N SERI A L # PAR T N O. 1 F le x B a ll Va lve A s s e m b ly 302-320A 2 ON/OF F Ro c k[...]

  • Page 7

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 7 (NG , LP) Exploded Parts Diagram Service Parts 6000TV -OAK Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: ______ Standing Pilot Ignition V alve Assembly 5 2 9 10 3 7 1 4 8 6 IT E M DESCRI PTI O N SERIA L # P A RT NUM BER 1 ON/OF F Ro c k e r S w i tc h 0[...]

  • Page 8

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 8 Appliance Certification The Heat & Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. Certification MODEL: 6000TV -OAK LABORA TOR Y : Underwriters Laboratories TYPE: V ented[...]

  • Page 9

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 9 2 Getting St arted Introducing the Heat & Glo Gas Fireplaces Heat & Glo B-type vent gas fireplaces are designed to op- erate with all exhaust gases expelled to the outside of the building. The information contained in this Installers Guide , unless noted otherw[...]

  • Page 10

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 10 Figure 1. Diagram of the 6000TV -OAK GA S ACCESS GAS CONT ROL S RA TING P LA T ES & LABELS VE N T COLLAR S HOOD ST ANDO FFS ACCE SS ELECT RICAL OUT SID E AIR GAS LIN E ACCES S 6-7/ 8 (174mm ) 2-1/8 (55mm) 38 (965m m) 36-1/ 8 (916mm ) 41 (1043mm ) 34- 5/8 (879m m) [...]

  • Page 11

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 11 3 Inst alling the Fireplace Step 1. Locating the Fireplace The diagram shows space and clearance requirements for locating a fireplace within a room. ABCD E 42” 22” 36” 51” 72” Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Fr[...]

  • Page 12

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 12 Step 3. Negative Pressure Make-up Air Negative Pressure warning : When negative pressure is present, an atmospherically vented fireplace (with a draft hood) may not function properly and it may down draft. In the case of a gas appliance, spillage of the combustion gas[...]

  • Page 13

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 13 ! ! Step 4. Inst alling the V ent System A. V ent System Approvals Model 6000TV -Oak is approved to use 6-inch (152mm) diameter B-type vent. B-type vent must be used when the vent system is within combustible construction. These models may also use single wall rigid o[...]

  • Page 14

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 14 ! C. Bedroom Installation in Canada This model MUST NOT be vented into a vent system in- stalled exterior to a building. The part of the vent system above the roof line can be exterior to the building. D. V ent T ermination WARNING: MAJOR U.S. BUILDING CODES SPECIFY M[...]

  • Page 15

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 15 Figure 9. Gas Supply Line • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing. • At the gas line access hole the gap between the supply piping and gas access hole can be plugge[...]

  • Page 16

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 16 Step 9. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS TO PREVENT ACCIDENT AL FIREPLACE OPERA TION. For Standing Pilot Ignition Wiring Appliance Requir[...]

  • Page 17

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 17 For Intermittent Pilot Ignition (IPI) Wiring 3 V olt T ransformer This appliance comes with a 3 volt transformer . The trans- former plugs into the junction box and the two leads plug into the green control module (see Figure 12). Appliance Requirements This appliance[...]

  • Page 18

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 18 Step 10. Finishing Figure 13 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace. See Figures 2 and 3 for other fireplace clearances. Only non-combus[...]

  • Page 19

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 19 Glass Specifications: TEMPERED Figure 16. Placement of the Ember Material Figure 15. Glass Assembly Step 12. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork from underneath the fireplace. Review safety war[...]

  • Page 20

    Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 20 4 Maint aining and Servicing Y our Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an appli- ance check-up at t[...]