Go to page of
Similar user manuals
-
Heat Pump
Heat Controller VMC24SB-1/VMH24SB-1
66 pages 1.6 mb -
Heat Pump
Heat Controller VMH 30
11 pages 1.39 mb -
Heat Pump
Heat Controller EKTH09-2G
28 pages 1.4 mb -
Heat Pump
Heat Controller HTV
48 pages 0.85 mb -
Heat Pump
Heat Controller B-VMH12FC-1
25 pages 1.59 mb -
Heat Pump
Heat Controller A-VMH36QC-1
25 pages 1.59 mb -
Heat Pump
Heat Controller VMH12SB-1
19 pages 1.83 mb -
Heat Pump
Heat Controller 7602-503
8 pages 1.8 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Heat Controller HBH 072 - 120, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Heat Controller HBH 072 - 120 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Heat Controller HBH 072 - 120. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Heat Controller HBH 072 - 120 should contain:
- informations concerning technical data of Heat Controller HBH 072 - 120
- name of the manufacturer and a year of construction of the Heat Controller HBH 072 - 120 item
- rules of operation, control and maintenance of the Heat Controller HBH 072 - 120 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Heat Controller HBH 072 - 120 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Heat Controller HBH 072 - 120, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Heat Controller service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Heat Controller HBH 072 - 120.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Heat Controller HBH 072 - 120 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
W a ter Sour ce Hea t Pump Systems SUBMITT AL DA T A Unit Designation Job Name Architect Engineer Contractor PERFORMANCE DA T A Cooling Capacity BTUH EER Heating Capacity BTUH COP Ambient Air o F Entering W ater T emp (Cooling) o F Entering Air T emp (Cooling) o F Entering W ater T emp (Heating) o F Entering Air T emp (Heating) o F Airow CFM [...]
-
Page 2
[...]
-
Page 3
Submittal Data HBH SerieS Heat Contr oller , Inc. 1 Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 1 Selection Procedure ................................................................................................................................................................ 2 HBH Series Nomenclature .............................[...]
-
Page 4
Heat Contr oller , Inc. HBH SerieS Submittal Data 2 Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 2 LW T = EW T - HE GPM x 500 LA T = EA T + HC CFM x1.08 LW T = EW T + HR GPM x 500 LA T (DB) = EA T (DB) - SC CFM x1.08 LC = TC - SC S/T = SC TC Heating Cooling To conver t Inch-Pound (English) to SI (Metric) Air Flow Correction T able 40[...]
-
Page 5
Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 3 Step 1 Determine the actual heating and cooling loads at the desired dry bulb and wet bulb conditions. Step 2 Obtain the follo wing design parameters: Entering wat er temperature , water ow r ate in GPM, air ow in CF M, water ow [...]
-
Page 6
Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 4 Model Nomenclature Heat Controller OEM Price List HBH Large Com pact Hor izonta l Units Entering W ater Temperature Range: 20 - 120° F (-6. 7 - 48.9° C) Horiz ontal Si zes 072 - 120 HBH Large M odel Struc ture Basic Uni t Descript ion: [...]
-
Page 7
Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 5 P er formance Data AHRI/ASHRAE/ISO 13256-1 ASHRAE/AHRI/ISO 13256-1. English (I-P) Units Model W ater Loop Heat P ump Ground W ater Heat P ump Ground Loop Hea t Pump Cooling 86°F Heating 68°F Cooling 59°F Heating 50°F Cooling 77°F Hea[...]
-
Page 8
Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 6 F or operation in the shaded area when wat er is used in lieu of an anti-freeze solution, the L W T (Leaving Water T emperatur e) must be calculated. F low must be maintained to a lev el such that the L W T is maintained above 42°F [5.6?[...]
-
Page 9
Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 7 P er formance Data: HBH072 Performance capacities shown in thousands of Btuh 2400 CFM Nominal Airow Heating & Cooling W A TER/BRINE Cooling - EA T 80/67°F Heating - EA T 70°F EWT °F FL OW gpm PD psi PD ft. TC SC kW HR EER HC kW [...]
-
Page 10
Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 8 P er formance Data: HBH096 Performance capacities shown in thousands of Btuh 3200 CFM Nominal Airow Heating & Cooling W A TER/BRINE Cooling - EA T 80/67°F Heating - EA T 70°F EWT °F FL OW gpm PD psi PD ft. TC SC kW HR EER HC kW [...]
-
Page 11
Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 9 P er formance Data: HBH120 Performance capacities shown in thousands of Btuh 4000 CFM Nominal Airow Heating & Cooling W A TER/BRINE Cooling - EA T 80/67°F Heating - EA T 70°F EWT °F FL OW gpm PD psi PD ft. TC SC kW HR EER HC kW [...]
-
Page 12
Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 10 Air Flow C orrection T able Entering Air Correction T able HBH P er formance Data Correction T ables Per centage of Rated Airow Cooling Heating T otal Capacity Sensible Capacity Pow er Heat of Rejection Heating Capacity Pow er Heat of[...]
-
Page 13
Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 11 Antifreez e Correction T able Antifreeze T ype Antifreeze % Cooling Heating WPD Corr . F ct. EW T 30°F EW T 90°F EW T 30°F T otal Cap Sens Cap Po we r Htg Cap Powe r Wat e r 0 1.000 1.000 1.000 Propylene Gly col 5 0.995 0.995 1.003 0.[...]
-
Page 14
Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 12 Blower P er formance Data HBH072 - Standard Unit All Data is Wet Coil SCFM ESP 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1800 BHP 0.28 0.32 0.35 0.39 0.42 0.45 0.48 0.52 0.56 0.60 0.64 0.69 0.72 0.76[...]
-
Page 15
Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 13 Blower P er formance Data HBH096 - Standard Unit All Data is Wet Coil SCFM ESP 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 2400 BHP 0.45 0.50 0.54 0.59 0.63 0.69 0.74 0.80 0.85 0.90 0.94 0.99 1.04 1.10[...]
-
Page 16
Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 14 Blower P er formance Data HBH096 - Standard Unit SCFM ESP 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 3300 BHP 1.01 1.08 1.14 1.21 1.28 1.33 1.39 1.45 1.51 1.58 1.64 1.72 1.78 1.84 1.93 2.00 Sheave/Mtr[...]
-
Page 17
Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 15 Blower P er formance Data HBH120 - Standard Unit All Data is Wet Coil SCFM ESP 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 3000 BHP 0.75 0.81 0.86 0.91 0.97 1.03 1.09 1.15 1.21 1.27 1.34 1.41 1.47 1.54[...]
-
Page 18
Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 16 Blower P er formance Data HBH120 - Standard Unit All Data is Wet Coil T able Continued from Pr evious Page SCFM ESP 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 4300 BHP 2.00 2.07 2.16 2.23 2.31 2.41 2.[...]
-
Page 19
Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 17 HBH Phy sical Data Model 072 096 120 Compressor Quantity Scroll Number of Circuits (C ompressors) 2 F actory Charge R-410a (oz) [kg] per circuit 60 [1.70] 76 [2.15] 80 [2.27] Blower Motor Blower Motor Quantity 1 Standard Motor (hp) [kw] [...]
-
Page 20
Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 18 HBH072-120 Dimensional Data DIMENSIONAL DA T A T ABLE ON NEXT P AGE LEFT RETURN STRAIGHT DISCHARGE CAP CAP FRONT BSP A EAP CBP B A O P Q R K M F G E D BSP RIGHT RETURN STRAIGHT DISCHARGE 1 EAP 2 CAP CAP 2 FRONT CBP 1 5 4 LEGEND CAP=Compr[...]
-
Page 21
Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 19 HBH072-120 Dimensional Data Model Overall Cabinet Discharge Connections Duct Flange Wat er Connections Electrical Knockouts Return Air Connections Using Return Air Opening A Depth B Width C Height D E Supply Depth F Supply Width G Supply[...]
-
Page 22
Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 20 HBH Electrical Data Standard HB Model V oltage Code Rated V oltage V oltage Min Max Blower Option Compressor Fan Motor FLA T otal Unit FLA Min Circuit Amp Max F use/ HACR QT Y RLA LRA 072 H 208-3-60 197/254 A, B, C 2 10.4 73.0 4.0 24.8 2[...]
-
Page 23
Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 21 T ypical W iring Diagram Three P hase HBH072-120 With CXM C ontroller[...]
-
Page 24
Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 22 Th is pro du c t s pe ci fic a tio n d oc ume nt is fur ni she d as a m ea ns to co py an d pa s te Cl ima te Ma s te r p rod uc t i n forma tio n i nto a proje c t spec i fic a tio n. It is n ot in ten d ed to be a co m pl e te lis t [...]
-
Page 25
Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 23 HBH Series 60H z Engineering Specications Page 2 General: Furnish and install the HBH Series as indicated on the plans. Equipment shall be completely assembled, piped and internally wired. Capacities and characteristics as listed in t[...]
-
Page 26
Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 24 HBH Series 60H z Engineering Specications Page 3 Fan and Motor Assembly: All units shall have belt-driven single centrifugal fan. Fan motor shall be permanently lubricated with thermal overload protection. Units supplied without perma[...]
-
Page 27
Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 25 HBH Series 60H z Engineering Specications Page 4 Option: The unit shall be supplied with stainless steel drain pan. Electrical: A control box shall be located within the unit compressor compartment and shall contain a 75V A transforme[...]
-
Page 28
Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 26 Hose Kit Assemblies: The following assemblies ship with the valves already assembled to the hose described: a. Supply and return hoses having ball valve with PT port. b. Supply hose having ball valve with PT port; return hose having auto[...]
-
Page 29
[...]
-
Page 30
06/2012 04/2009 1 1/2010[...]