Heatcraft Refrigeration Products Air Defrost RLC manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Heatcraft Refrigeration Products Air Defrost RLC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Heatcraft Refrigeration Products Air Defrost RLC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Heatcraft Refrigeration Products Air Defrost RLC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Heatcraft Refrigeration Products Air Defrost RLC should contain:
- informations concerning technical data of Heatcraft Refrigeration Products Air Defrost RLC
- name of the manufacturer and a year of construction of the Heatcraft Refrigeration Products Air Defrost RLC item
- rules of operation, control and maintenance of the Heatcraft Refrigeration Products Air Defrost RLC item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Heatcraft Refrigeration Products Air Defrost RLC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Heatcraft Refrigeration Products Air Defrost RLC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Heatcraft Refrigeration Produc service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Heatcraft Refrigeration Products Air Defrost RLC.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Heatcraft Refrigeration Products Air Defrost RLC item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    www .chandlerref.com LOW PROFILE UNIT COOLER T echnical Guide Models RL C | Air Defrost EL C/EFC | Electric Defrost GL C | Hot Gas Defrost CHL OPTB May , 2008 Replaces CH-B-15B, March 2004 y 2007[...]

  • Page 2

    2 Nomenclature ......................................................................................................................................................................................................... 2 F eatures & Benets .........................................................................................................[...]

  • Page 3

    3 Featur es & Benefits Cabinet Minimal height of the low profile series makes it ideal for low c eiling coolers Cabinet design f eatures fron t access panels on each side for easy access to electrical and refrigeration componen ts All electrical components factor y wired to terminal board and identified , mak ing it easy to field wire the unit[...]

  • Page 4

    4 Performance Data Model RL C Air Defrost | 60 Hz Model Capacity F an Data 10°F TD 25°F SST 6°C TD -4°C SST No. CFM m 3 H BTUH W at ts RL C040 4,000 1,170 1 730 1,240 RL C052 5,200 1,520 1 700 1,189 RL C065 6,500 1,900 1 650 1,104 RL C070 7,000 2,050 2 1,460 2,481 RL C090 9,000 2,640 2 1,400 2,379 RL C104 10,400 3,050 2 1,400 2,379 RL C120 12,0[...]

  • Page 5

    5 Model RL C Air Defrost | 50 Hz Model HP PSC Motor EC Motor 110/1/50 220/1/50 380/1/50 110/1/50 220/1/50 Amp s Wat t s Amp s Wat t s Amp s Wat t s Amp s Wat t s Am ps Wat t s RL C040 1/15 1.0 68 0.5 65 0.4 82 0.9 57 0.5 59 RL C052 1/15 1.0 68 0.5 65 0.4 82 0.9 57 0.5 59 RL C065 1/15 1.0 68 0.5 65 0.4 82 0.9 57 0.5 59 RL C070 1/15 2.0 136 1.0 130 0[...]

  • Page 6

    6 Model EL C/EFC Elec tric Defrost | 60 Hz Model Capacity F an Data 10°F TD -20°F SST 6°C TD -29°C SST No. CF M m 3 H BTUH W atts 6 Fins P er Inch EL C035 3,500 1,025 1 700 1,189 EL C040 4,000 1,170 1 700 1,189 EL C047 4,700 1,380 1 650 1,104 EL C065 6,500 1,900 2 1,400 2,379 EL C075 7,500 2,200 2 1,300 2,209 EL C090 9,000 2,640 2 1,300 2,209 E[...]

  • Page 7

    7 Specifications Model EL C/EFC Elec tric Defrost | 60 Hz Model HP Shaded P ole Motor PSC, PSC- TE Motor EC Motor Defrost Heaters 208-230/1/60 208-230/1/60 460/1/60 208-230/1/60 W atts 230/1/60 230/3/60 460/1/60 T otal Amps Am ps Wat t s A mp s Wat t s Am ps Wa t ts A m ps Wat t s 6 Fins P er Inch EL C035 1/15 1.0 122 0.5 91 0.4 117 0.5 59 900 3.9[...]

  • Page 8

    8 Performance Data Model GL C Hot Gas Defrost | 60 Hz Model Capacity F an Data 10°F TD -20°F SST 6°C TD -29°C SST No. CF M m 3 H BTUH W atts 6 Fins P er Inch GL C035 3,500 1,025 1 700 1,189 GL C040 4,000 1,170 1 700 1,189 GL C047 4,700 1,380 1 650 1,104 GL C065 6,500 1,900 2 1,400 2,379 GL C075 7,500 2,200 2 1,300 2,209 GL C090 9,000 2,640 2 1,[...]

  • Page 9

    9 Specifications Model GL C Hot Gas Defrost | 60 Hz Model HP Shaded P ole Motor PSC, PSC- TE Motor EC Motor Drain Pan H eaters * 115/1/60 208- 230/1/60 115/1/60 208- 230/1/60 460/1/60 115/1/60 208- 230/1/60 W atts 115/1/60 230/1/60 460/1/60 T otal Amps Am ps Wat t s A mp s Wat t s Am ps Wa t ts A m ps Wat t s A mp s Wat t s Am ps Wa t ts A mp s Wa[...]

  • Page 10

    10 Physical Data Model RL C Air Defrost Model No . of F ans Connections (in.) Appro x. Net Wt. Coil Inlet OD Suction ID External Equalizer OD Drain MPT lbs. kg RL C040 1 1/2 5/8 1/4 3/4 28 13 RL C052 1 1/2 5/8 1/4 3/4 31 15 RL C065 1 1/2 7/8 1/4 3/4 34 16 RL C070 2 1/2 7/8 1/4 3/4 45 21 RL C090 2 1/2 7/8 1/4 3/4 48 22 RL C104 2 1/2 7/8 1/4 3/4 49 2[...]

  • Page 11

    11 The standard desig n for the Chandler L ow Prole Ev aporator incorpora tes a hot gas loop in the drain pan. Utilizing a hot gas loop is ideal for hot gas defr ost applications where high temper ature gas can be maintained t o defrost both the evaporator dr ain pan and coil. F or applications where cooler (lower) t emperature hot gas is used f[...]

  • Page 12

    12 Dimensional Data Dimensional Data F or All Models Air Defrost Model Electric and Hot Gas Defrost Model No . of F ans Dimensions A B C D 6 FPI 6 FPI 4 FPI in. mm in. mm in. mm in. mm 040 035 - 1 29.50 749.3 17.25 438.1 - - - - 052 040 - 1 29.50 749.3 17.25 438.1 - - - - 065 047 041 1 29.50 749.3 17.25 438.1 - - - - 070 - - 2 45.50 1,155.7 33.25 8[...]

  • Page 13

    13 The hot gas unit coolers can be used in r everse cycle hot gas defrost syst ems using multiple evaporators connected to one condensing unit. Generally , not more than one-third of the system defrosts a t one time. During the reverse cycle defrost, the r eversing valve; locat ed in the compressor dischar ge line, diverts hot gas through the sucti[...]

  • Page 14

    14 In the refrigeration cycle, the thermostatic expansion valve bypass assembly check v alve only allow s refrigerant ow through the thermostatic expansion v alve and into the evaporator c oil. As the r efr igerant vapor exits the coil at the suction line, the check valve of the drain pan loop check valve assembly pr events the r efrigerant vapo[...]

  • Page 15

    15 The hot gas defrost unit coolers c onforms to the standard 3-pipe hot gas system using a check valve assembly , an electrical control to terminate the defrost, and a hot gas solenoid valv e. The check valve assembly transports the hot gas between the drain pan loop and the sideport distributor of the coil. The check valv e assembly kit is availa[...]

  • Page 16

    16 Cabinet C omponents Part # Description No . Fans 40480101 Drain P an Air & Hot G as Defrost 1 40480201 Drain P an Air & Hot G as Defrost 2 40480301 Drain P an Air & Hot G as Defrost 3 40480401 Drain P an Air & Hot G as Defrost 4 40480501 Drain P an Air & Hot G as Defrost 5 40480601 Drain P an Air & Hot G as Defrost 6 4048[...]

  • Page 17

    17 Standar d Nozzle Selection Model RL C Air Defrost Model No . of F ans Distributor T ube (in.) No . of Circuits R-404A R-22 OD Length RL C040 1 3/16 15 1 - - RL C052 1 3/16 15 1 - - RL C065 1 3/16 15 2 L-1/2 L -1/3 RL C070 2 3/16 15 2 L-1/2 L -1/3 RL C090 2 3/16 15 3 L-3/4 L -1/2 RL C104 2 3/16 15 3 L-3/4 L -1/2 RL C120 2 3/16 15 3 L -1 L-3/4 RL [...]

  • Page 18

    18 Notes[...]

  • Page 19

    19 Notes[...]

  • Page 20

    A Brand of Heatcraft Refrigeration P roduc ts LL C 2175 W est Park Place Blv d. • Stone Mountain, GA • 30087 800-321-1881 • F AX 770-465-5990 ww w .chandlerref .com Since product improvement is a c ontinuing eor t, we reserve the right to make changes in specications without notice . F or more information on Chandler refrigeration pr od[...]