Heatcraft Refrigeration Products H-IM-80C manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Heatcraft Refrigeration Products H-IM-80C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Heatcraft Refrigeration Products H-IM-80C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Heatcraft Refrigeration Products H-IM-80C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Heatcraft Refrigeration Products H-IM-80C should contain:
- informations concerning technical data of Heatcraft Refrigeration Products H-IM-80C
- name of the manufacturer and a year of construction of the Heatcraft Refrigeration Products H-IM-80C item
- rules of operation, control and maintenance of the Heatcraft Refrigeration Products H-IM-80C item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Heatcraft Refrigeration Products H-IM-80C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Heatcraft Refrigeration Products H-IM-80C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Heatcraft Refrigeration Products service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Heatcraft Refrigeration Products H-IM-80C.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Heatcraft Refrigeration Products H-IM-80C item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Beacon II Smart Controller Installation & Operation Manual H-IM-80C ( 12/03) December , 2003 Part No. 25000601 Replaces H-IM-80B (12/02) Features ................................................................ 2-3 Installation ............................................................. 4 Wiring ...............................................[...]

  • Page 2

    2 The Beacon II Smart Controller performs all the standard Beacon functions with the additional benefit of: a) Remote mounting for easy access b) Remote monitoring and programming c) Controlling four completely separate systems d) Logging data e) Smart Defrost f) Access via PC or modem g) Has buzzer to signal alarms h) Locking keypad Beacon II Smar[...]

  • Page 3

    3 Features of the Beacon II Smart Controller • Monitoring of the complete refrigeration system. • Programming of a variety of parameters for the optimum control of the refrigeration system. • The Beacon II Smart Controller has a Liquid Crystal Display (LCD) which shows: current time, actual box temperature, box temperature set-point and if th[...]

  • Page 4

    4 INST ALLA TION The Beacon II Smart Controller should be installed in a location where the large Liquid Crystal Display (LCD) can be viewed easily , yet is secure and vibration free. Because of the LCD screen, the Beacon II Smart Controller should not be mounted where it will experience temperatures below 40 ° F or above 100 ° F. A terminal stri[...]

  • Page 5

    5 WIRING All 24 volt wiring must be run separate from the line voltage wiring . All Low voltage wiring must be 18 gauge minimum and must be run separate from high voltage wiring. The maximum distance from the Beacon II Smart Controller t o the Master Evaporator is 1000 ft. The terminal strip in the Beacon II Smart Controller i s labeled similarly t[...]

  • Page 6

    6 For the second system, connect MUL TI OUT 2 from the Beacon II Smart Controller t o the MUL TI IN on the Beacon II board on the Evaporator in this second system. Then connect MUL TI IN 2 from the Beacon II Smart Controller t o t h e MUL TI OUT on the Beacon II board on the Evaporator on this second system. See typical wiring diagram at the back o[...]

  • Page 7

    7 will continue to operate and maintain the box temperature. This occurs only if an external power supply is used on the Beacon II Smart Controller . If the Beacon II Smart Controller LCD displays all 88888 this indicates that the power supply is below 18 V AC. When this occurs the system will power down and shut off. When the power supply is corre[...]

  • Page 8

    8 • COOLING: Depressing this button will start the system in the cooling cycle immediately (The 4 minutes “Hold Off” is bypassed). This button will illuminate to indicate that the Cooling function is “ON”. System operation will be as described under REFRIGERA TION MODE in the Beacon II installation manual. Pressing the COOLING button whil[...]

  • Page 9

    9 • SUPRHT – Superheat: 4 to 20 ° F . Use “SETPOINT” slide-bar to select desired superheat temp., then press “ENTER.” If multiple evaporators are connected, use the “+” button to set other evaporators on this system. • SMT DFT : Smart Defrost: On/Of f. Use “SETPOINT” slide-bar to turn it ON or OFF , then press “ENTER” - ([...]

  • Page 10

    10 • EXVSET - Expansion valve step setting (Stepper Motor setting 0 to 255 steps: use + button to check other evaporators if Master/slave) • SUCTMP – Evaporator Suction temperature (Measured by the Suction Sensor) • SSVTMP – Saturated Suction temperature at the Evaporator (Determined by Suction T ransducer) • SUCPRE – Evaporator Sucti[...]

  • Page 11

    11 • *SPSEN - Suction pressure transducer shorted, open or not installed • *ODSEN - Outdoor temperature sensor shorted • *SUPLO - Superheat too low • *SHTDN - Compressor shutdown (High or low refrigerant pressure or low oil pressure) The error code will flash alternately with the normal display information. When the error condition is corre[...]

  • Page 12

    12 The system will pumpdown, cycle off and try to restart for three consecutive times. Each try will be after the 4 minutes “Hold Off” period, for the following fault conditions. Oil pressure High pressure or low pressure cutout (or any other compressor safeties) After the third try , the Alarm contacts will be closed and an alarm message displ[...]

  • Page 13

    13 Real-time data can also be recorded and stored on a Desktop PC while the PC is connected to the Beacon II Smart Controller . The PC will continuously request information from the Beacon II Smart Controller regarding system operation and setup and record this data every minute, in an Excel spreadsheet. This information is stored to the PC hard dr[...]

  • Page 14

    14 PC & MODEM ACCESS For access to the system from a PC directly or via a modem, the SMART II Software must be purchased and installed on your PC. With PC access, ALL system settings can be monitored, changed or logged from a remote location. The stored data can be viewed in an Excel spreadsheet. Recommended Requirements PC with a 233 Mhz clock[...]

  • Page 15

    15 SYSTEM DEF AUL TS Following are factory defaults for the parameters which can be programmed in the Beacon II Smart Controller . If the user does not select a setting for any of the following parameters, the default will be used. It is important the user set ALL parameters based of their needs. P ARAMETERS CODE AIR ELECTRIC Refrigerant REFTYP R22[...]

  • Page 16

    16 Parts Parts List HRP P ART P ART DESCRIPTION NUMBER Beacon II Control Board 28910101 T emperature Sensor kit – White Leads* 89904902 T ransformer 120/24 volt – 40 V A 22529601 T ransformer 240/24 volt - 40 V A 22529602 T ransformer 460/24 volt – 40 V A 22529603 T ransformer 575/24 volt – 40 V A 22529701 Pilot Relay 2251 1401 Contactor fo[...]

  • Page 17

    17 Beacon II T roubleshooting Guide PROBLEM Step ACTION ITEM IF OK IF NOT OK 1. Check Primary Power Supply Disconnect 1. Check fuses and circuit breakers 2. Check V oltage to Evaporator Transformer Go to 2. Check field wiring for breaks LED is not lit. 3. Check T ransformer Secondary Output V olts next step 3. Replace if necessary 4. Check V oltage[...]

  • Page 18

    18 PROBLEM Step ACTION ITEM IF OK IF NOT OK 1. Check wiring connection to the board • Correct field wiring to the board 2. Low Pressure Safety (LPS) T ripped: • Check for correct refrigerant type • Change setpoint to match refrigerant • Check refrigerant charge • Add more refrigerant to proper charge • Check LPS setting • Correct LPS [...]

  • Page 19

    19 Beacon II T roubleshooting Guide (continued) PROBLEM Step ACTION ITEM IF OK IF NOT OK E9 Multi-out to Multi-in 1. Check for 24 volts power to the board 1. If no voltage, see “LED is not lit” above Communication Wiring for low voltage, see “88888 LED display” (only shows after initial 2. Check for crossed communication wiring Go to 2. Cor[...]

  • Page 20

    20 PROBLEM Step ACTION ITEM IF OK IF NOT OK 1. Check system operation: Is it running? 1. Check power to condensing unit Check position of Service Mode switches Check compressor overloads and contactor 2. Check system charge 2. Add or remove refrigerant to proper charge 3. Check for proper operating superheat 3. Check EEV operation Check control boa[...]

  • Page 21

    21 Wiring Diagrams[...]

  • Page 22

    22 Wiring Diagrams[...]

  • Page 23

    23 Wiring Diagrams[...]

  • Page 24

    Heatcraft Refrigeration Products LLC 2175 West Park Place Blvd • Stone Mountain, GA 30087 (770) 465-5600 • Fax (770)465-5990 www .heatcraftrpd.com Since product improvement is a continuing effort, we reserve the right to make changes in specifications without notice.[...]