Heath Zenith 4162 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Heath Zenith 4162, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Heath Zenith 4162 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Heath Zenith 4162. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Heath Zenith 4162 should contain:
- informations concerning technical data of Heath Zenith 4162
- name of the manufacturer and a year of construction of the Heath Zenith 4162 item
- rules of operation, control and maintenance of the Heath Zenith 4162 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Heath Zenith 4162 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Heath Zenith 4162, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Heath Zenith service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Heath Zenith 4162.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Heath Zenith 4162 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Motion Sensing Coach Lights T ail Assembly (Lantern & Coach)* Features • Light comes on when motion is detected. • A utomatically tur ns light off . • Photocell k eeps the light off during da ylight hours. This package includes: © 2007 HeathCo LLC 595-5530-13 Set ON-TIME s witch to 1, 5, or 10 minutes. ON-TIME Set the ON-TIME s witch on [...]

  • Page 2

    2 595-5530-13 MANUAL MODE AUTO TEST ON-TIME Switch at 1, 5, or 10 minutes Mode Switching Summary Flip light switch off for one second then back on* * If you get confused while switching modes, tur n the po wer off for one minute , then bac k on. After the calibration time the control will be in the A UT O mode. INST ALLA TION F or b est pe rf orman[...]

  • Page 3

    3 595-5530-13 Wire P ath WIRING One Motion Light Black White Green or Bare Light Fixture CA UTIO N: DO NO T conn ect the RED wir e unles s y ou wa nt to contr ol ot her lig hts fr om the mot ion sen sor . Note: All wir ing should be run in accordance with the National Electrical Code through conduit or another acceptable means. Contact a qualified[...]

  • Page 4

    4 595-5530-13 OPTIONAL WIRING Thi s fixtur e is pro vide d with a sens or rat ed f or 500 W att s. Since the fixture wattage is less than 500 w atts, then additional lighting load can be controlled. F or e xample, if the fixture is rated f or 100 watts , then 400 watts of additional lighting load can be controlled. When determining what a fixtu[...]

  • Page 5

    5 595-5530-13 4162 T op Assembl y Larger piece on top ❒ Caulk fixture mounting surface with silicone weather sealant. ❒ Install light b ulb . See fixture markings for proper bulb type and w attage. ❒ If so equi ppe d, in sta ll th e fixt ure top . Sec ure with decorativ e screws . ❒ If you will not be installing the optional tai[...]

  • Page 6

    6 595-5530-13 TEST 1 5 10 MIN ON-TIME LO - M - HI SENSITIVITY ❒ Set SENSITIVITY to mid position and ON-TIME to TEST position. TESTING ❒ T urn on the circuit breaker and light switc h. ❒ Se t th e S EN SI TI VIT Y a s ne ed ed . T oo mu ch sen siti vit y ma y in crea se f alse trig gerin g. ❒ Set the amount of TIME y ou want the light to sta[...]

  • Page 7

    7 595-5530-13 SPECIFICA TIONS Range . . . . . . . . . . . Up to 3 0 f t. (9.1 m) [ v a ri es wi t h s u r r o u nd in g t em pe r a tu re ] Sensing Angle . . . . . Up to 150° Electrical Load . . . . . See rating on fixture f or maximum wattage Sensor Capacity . . . U p to 5 00 W at ts (4 .1 A.) Maximum T ungsten Incandescent P o wer Requirements [...]

  • Page 8

    8 595-5530-13 FIVE YEAR LIMITED W ARRANTY This is a “Limited W arranty” which gives y ou specific legal rights. Y ou may also hav e other rights which vary from state to state or province to province . F or a per iod of fiv e years from the date of purchase , an y malfunction caused by f actor y def ective par ts or workmanship will be correc[...]

  • Page 9

    9 595-5530-13 9 ON-TIME TEST 1 5 10 MIN ON-TIME Modalidad: A tiempo: T rabaja: Día Noche Prueba 5 seg. x x A utom. 1, 5 ó 10 min. x Manual Hasta el amanecer* x FUNCIONAMIENT O Este paquete contiene: Características • La luz se prende cuando se detecta movi- miento . • Apaga la luz automáticamente. • La f otocélula mantiene la luz apagada[...]

  • Page 10

    10 595-5530-13 Muev a el interruptor de tiempo (ON-TIME) a 1, 5 ó 10 minutos Apague el interruptor por un segundo y préndalo de nuev o* PR UEBA A UTOM. MODO MANU AL * Si se confunde mientras cambia de f ases, apague la electricidad por un minuto y préndala de nuev o . Después del tiempo de calibración el control estará en f ase A UTO(MA TICA)[...]

  • Page 11

    11 595-5530-13 CABLEADO Luz de un movimiento Negro Blanco V erde o Desnudo Aparato de Luz CUI D AD O: NO con ect e el cab le R OJ O except o que desee contr olar otras luces desde el detector de movimiento. Nota : T odo el cab leado debe realizarse de acuerdo con el Código Eléctrico Nacional usando tubería ó algún otro medio aceptable. Póngas[...]

  • Page 12

    12 595-5530-13 Es también posib le conect ar dos luces detector as de movimi ento de manera que cada apar ato prenda ambas luces al mismo tiempo (sistema de dob le maestro). Se recomienda que sólo personas con amplios conocimientos de electr icidad conecten este tipo de configuración. P or f av or comuníquese con nuestro depar tamento de asist[...]

  • Page 13

    13 595-5530-13 La pieza inf erior de adorno tiene un agujero de desagüe. 2. P onga la pieza de e xtensión y el adorno. 1. Atornille la barra y la tuerca de e xtensión. T uerca he xagonal 3. P onga la tuerca decorativ a. Ensamble superior del modelo 4162 La pieza más grande debe estar arriba ❒ C al af a t ee el ap a r a t o y la su pe r fic i[...]

  • Page 14

    14 595-5530-13 TEST 1 5 10 MIN ON-TIME LO - M - HI SENSITIVITY ❒ Fije el interruptor SENSITIVITY a la posición media y el de ON-TIME a la posición de TEST . PR UEB A ❒ Prend a el cor tacir cu itos y el interrup tor de luz. ❒ Cami ne por el área de prot ección dándose cuenta dónde está cuando la luz se pren- de. Mue va la cabeza del det[...]

  • Page 15

    15 595-5530-13 GUIA DE INVESTIGA CION DE A VERIAS Alcance . . . . . . . . . . . Hasta 9.1 m. (v aría con la temperatura del medio ambiente). Angulo de detección . Hasta 150° Carga Eléctrica . . . . . V ea el nú me ro m áx i- mo de vatios en los v alores nominales del ar tefacto Capacidad del Detector . . . . . . . . . . . Hasta un máximo de [...]

  • Page 16

    16 595-5530-13 GARANTÍA LIMIT AD A A 5 AÑOS Esta es una “Garantía Limitada” que le da a Ud. derechos legales específicos. Usted puede también tener otros derechos que varían de estado a estado o de pro vincia a provincia. Po r u n pe rí od o d e 5 años desde la fecha de compra, cualquier mal funcionamiento ocasionado por par tes defect[...]

  • Page 17

    17 595-5530-13 ON-TIME TEST 1 5 10 MIN TEST 1 5 10 MIN ON-TIME Caractéristiques • Allume l’éclairage lorsqu’un mouvement est détecté. • Éteint automatiquement l’éclairage . • Photocellule qui maintient l’éclairage éteint pendant la période de lumière du jour . Cet emballage contient: Exigences • La commande d'éclaira[...]

  • Page 18

    18 595-5530-13 PRIORITÉ MANUELLE AUTO TEST * Si vous ne sav ez plus dans quel mode se trouv e l’appareil, couper l’alimentation pendant une minute puis la rétablir . Après le temps d’étalonnage, la commande re viendra au mode A UT O. Placer l’interrupteur ON- TIME à 1, 5 ou 10 minutes Mettre l’interrupteur hors cir cuit pendant une s[...]

  • Page 19

    19 595-5530-13 Noir à noir Blanc à blanc CÂBLA GE Mé th o de d e mi s e à la t e rr e re co m ma nd ée Utilisez une «queue de cochon» ver te (non f our nie) et torsadez-en une e xtrémité av ec le fil nu du luminaire et le fil de terre de la boît e de jonct ion. Utili sez un serr e-fil s. Fix ez l'autre extrémité de la «queue d[...]

  • Page 20

    20 595-5530-13 Il est aussi possible de raccorder deux luminaires à détection de mouv ement de sor te que l’un ou l’autre des appareils allume simultanément les deux luminaires (double circuit maître). Il est recommandé que seuls des gens possédant une grande e xpérience de l’électricité tentent de réaliser cette configuration. A v[...]

  • Page 21

    21 595-5530-13 COMPLÉTEZ L'INST ALLA TION Ensemble supérieur 4162 Plus grande pièce sur le dessus 1. Visser la tige de rallonge. 2. Ajouter la queue et l’élément décoratif . La pièce décorativ e inférieure compor te un orifice de drainage Écrou he xagonal Ensemble facultatif ❒ S’il y a lieu, installer la queue décorative comm[...]

  • Page 22

    22 595-5530-13 TEST 1 5 10 MIN ON-TIME LO - M - HI SENSITIVITY ❒ Placez le commutateur SENSITIVITY en position médiane et le commutateur ON- TIME à TEST . ESSAIS ❒ Mettre en circuit le disjoncteur et l’in- terrupteur d’éclaira ge . Éviter de pointer l’appareil: • Sur des flaques d’eau ou des objets dont la température change rap[...]

  • Page 23

    23 595-5530-13 P or tée . . . . . . . . . . . . Jusqu’à 9,1 m (v ar ie selon la température environnante) Angle de détection . . . J usqu’à 150° Charge électrique . . . V oir la capacit é sur l’apparei l pour la puis- sance maximum Capacité du capteur . Jusqu’à 500 W (4,1 A) maximum T ungstène à incandescence Courant requis . . [...]

  • Page 24

    24 595-5530-13 GARANTIE LIMITÉE DE 5 ANS Il s’agit d’une « Garantie limitée » qui vous confère des droits juridiques spécifiques. V ous pouv ez également jouir d’autres droits, v ariables d’une province à l’autre . P endant une période de 5 ans à compter de la date d’achat, toute anomalie de fonctionnement imputable à un vic[...]