Heath Zenith Motion sensing Pendant Light 4350 manual
- Read online or download the manual
- 24 pages
- 1.6 mb
Go to page of
Similar user manuals
-
Home Safety Product
Heath Zenith SL-5408-WH
12 pages 0.71 mb -
Home Safety Product
Heath Zenith 2LBN2
16 pages 0.31 mb -
Home Safety Product
Heath Zenith PF-4150-PB
24 pages 0.83 mb -
Home Safety Product
Heath Zenith BL-2400
12 pages 0.82 mb -
Home Safety Product
Heath Zenith None
2 pages 0.12 mb -
Home Safety Product
Heath Zenith Motion Sensor 3-Way Wall Switch 6108
28 pages 0.84 mb -
Home Safety Product
Heath Zenith SL-5710
12 pages 0.37 mb -
Home Safety Product
Heath Zenith 2LBN1
24 pages 1.56 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Heath Zenith Motion sensing Pendant Light 4350, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Heath Zenith Motion sensing Pendant Light 4350 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Heath Zenith Motion sensing Pendant Light 4350. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Heath Zenith Motion sensing Pendant Light 4350 should contain:
- informations concerning technical data of Heath Zenith Motion sensing Pendant Light 4350
- name of the manufacturer and a year of construction of the Heath Zenith Motion sensing Pendant Light 4350 item
- rules of operation, control and maintenance of the Heath Zenith Motion sensing Pendant Light 4350 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Heath Zenith Motion sensing Pendant Light 4350 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Heath Zenith Motion sensing Pendant Light 4350, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Heath Zenith service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Heath Zenith Motion sensing Pendant Light 4350.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Heath Zenith Motion sensing Pendant Light 4350 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
FEA TURES • Light comes on when motion is detected. • Automatically turns light off. • Optional half power accent lighting. • Photocell keeps the light of f during daylight hours. • Hinged door for easy bulb access. 1 - Canopy Screws (x3) 2 - Uni ve rsa l M oun tin g B ra cke t 3 - Mounting Bracket Screws (x2) 4 - Nut 5 - Star W asher 6 -[...]
-
Page 2
2 598-1219-05 MANUAL MODE AUTO TEST ON-TIME TEST 1 5 10 MIN TEST Set ON-TIME switch to 1, 5, or 10 minutes. AUT O ON-TIME Switch at 1, 5, or 10 minutes ... back on. 1 Second OFF then ... Manual mode only works at ni gh t be ca us e da yl ig ht ret ur ns the sensor to AUTO. Flip the light switch of f for one second then back on to toggle between AUT[...]
-
Page 3
3 598-1219-05 INST ALL UNIVERSAL MOUNTING BRACKET Canopy Screw (x3) (T ightened Finger T ight) Junction Box Universal Mounting Bracket Mounting Bracket Screw (x2) ASSEMBLE CANOPY 1. De ter mi ne th e nu mbe r of moun ti ng rods nee ded to mount the pendant light. Any combination of the 3 mounting rods may be used. Note: For best performance, mount [...]
-
Page 4
4 598-1219-05 WIRING LIGHT FIXTURE Note: All wiring should be run in accordance with the National Electrical Code through conduit or another acceptable means. Contact a qualied electrician if there is any question as to the suitability of the system. 1. T o simplify installation, at- tach one end of S-hanger to S-hanger terminal (lo- cated insid[...]
-
Page 5
5 598-1219-05 Knurled Canopy Nut TESTING 1. T urn on the circuit breaker and light switch. Note: Sensor has a 1 1 / 2 minute warm up period before it will detect motion. When rst turned on wait 1 1 / 2 minutes. 2. T o remove sensor cover , unscrew the 4 sen- sor cover screws holding the sensor cover on bottom of light xture. INST ALL PENDANT [...]
-
Page 6
6 598-1219-05 Least Sensitive Most Sensitive The sensor is less sensitive to motion directly towards it and more sensitive to motion across coverage area. Motion Motion ADJUSTMENT OF COVERAGE AREA The sensor on this light xture detects “motion” by the movement of heat (body heat) across the coverage area. However , following are examples of [...]
-
Page 7
7 598-1219-05 DUAL B R IT E ® O N- T IME T E ST 1 5 10 MI N O FF 3 6 DU S K T O DA WN SPECIFICA TIONS Range ........................... Up to 30 ft. (9.1 m) [varies with surrounding temperature]. Sensing Angle ............... 360° Electrical Load .............. Up to 120 W att Maximum T ungsten Incandescent (Up to 60 W att Maximum each lampholder[...]
-
Page 8
8 598-1219-05 SYMPTOM Light stays on continuously . Light ashes on and off. Light does not stay on in Man - ual mode. POSSIBLE CAUSE 1. There is a heat source like an air vent, dryer vent, or brightly- painted, heat-reective surface in the coverage area. (Install shield on sensor in the direction of heat source.) 2. Sen sor is in Ma nua l M o[...]
-
Page 9
9 598-1219-05 DU AL B RI TE ® O N- TI ME TE S T 1 5 10 M I N O FF 3 6 DU S K TO DA W N © 2007 HeathCo LLC 598-1219-05 S CARACTERÍSTICAS • La l uz se p re n de c ua n do s e d et e c ta mo v i mi e nt o . • Apaga la luz automáticamente. • Al u m br a do d ec o ra t i vo op c i on a l a me d ia po t e nc i a. • La fotocélula mantiene la [...]
-
Page 10
10 598-1219-05 REQUISIT OS • El control de luz requiere 120 VCA. • Para usar el Sobrecontrol Manual, conecte el control con un interruptor . • Algunos códigos requieren instalación por un electricista calicado. FUNCIONAMIENT O Nota: Cuando lo prenda por primera vez espere 1 1 / 2 mi nut os par a que el ci rcu it o s e c lai bre . *Se pon[...]
-
Page 11
1 1 598-1219-05 INST ALE LA CONSOLA UNIVERSAL DE MONT AJE T ornillo del escude- te (x3) (apretado a mano) Caja de empalme Soporte universal de montaje T ornillo de la consola de montaje (x2) ENSAMBLE EL ESCUDETE 1. De t e rm i ne el nú m e ro de va r il l a s d e m on t aj e qu e ne c e si t a pa r a mo n t ar la lá m p ar a co l g an t e. Se p u[...]
-
Page 12
12 598-1219-05 CABLEADO DEL AP ARA T O DE LUZ Not a: T odo el cableado debe ser hecho de acuerdo al Código Eléctrico Nacional por medio de conduc- to s pa ra cab le s u otr as for ma s ac ep ta bl es . Pó ng as e en contacto con un electricista calicado si existe duda sobre la aptitud del sistema. 1. Para simplicar la insta - lación, suje[...]
-
Page 13
13 598-1219-05 PRUEBA 1. Prenda el cortacircuitos y el interruptor de luz. Nota: El detector tiene un período de cerca de 1 1 / 2 minutos de calentamiento antes de detectar movimiento. Cuando lo prenda por primera vez, espere 1 1 / 2 minutos. T uerca estriada del escudete 2. Para retirar la tapa del detector , desenrosque los 4 tornillos de esta t[...]
-
Page 14
14 598-1219-05 Lo menos sensible Lo más sensible El detector es menos sensible a movimientos hacia el detector y más sensible a movimientos transversales en el área de cobertura. Movimiento REGULACIÓN DEL ÁREA DE COBERTURA El detector de este aparato de luz detecta “mo - vimiento” gracias al movimiento del calor (calor corporal) a través [...]
-
Page 15
15 598-1219-05 DUAL B R IT E ® O N- T IME T E ST 1 5 10 MI N O FF 3 6 DU S K T O DA WN 2. Corte la cantidad necesaria de cinta espumosa que necesita para adherir la cubierta a la placa traslúcida. 3. Re t i re el pa pe l pr o te c to r de un la do de la ci n ta es p u mo s a y ad h ié r a la al i nt e ri o r d e l a cu b ie r t a. 4. Retire el p[...]
-
Page 16
16 598-1219-05 SINTOMA La luz se queda prendida conti - nua-mente. La luz se prende y se apaga. La luz no queda encendida en el modo manual. POSIBLE CAUSA 1. Hay una fuente de calor como ventosas de aire, respiradero de secadora, o hay en el área de cobertura una supercie brillante que re ej a calor . (I nst ale la cu bie rta en el detector [...]
-
Page 17
17 598-1219-05 © 2007 HeathCo LLC 598-1219-05 F CARACTÉRISTIQUES • Allume l’éclairage lorsqu’un mouvement est détecté. • Éteint automatiquement l’éclairage. • Éclairage d’appoint facultatif, à mi-puissance. • Photocellule qui maintient l’éclairage éteint pendant la période de lumière du jour . • Porte à charnière [...]
-
Page 18
18 598-1219-05 EXIGENCES • La commande d'éclairage nécessite une alimen- tation 120 volts c.a. • Si vous désir ez ut ili ser la prio rit é manu ell e, la com ma nde do it êtr e bra nch ée à u n i nt err upt eur . • Certains codes de bâtiment locaux peuvent exiger que l’installation soit faite par un électricien qualié. FON[...]
-
Page 19
19 598-1219-05 Boîte électrique Support de xation universel INST ALLA TION DU SUPPORT UNIVERSEL Vis de la monture (3) (serrées à la main) Vis du support universel (2) ASSEMBLAGE DE LA MONTURE 1. Dé t e rm i ne z le no mb r e de tig e s né ce s sa i r es à l ’i n s t a ll a t i o n du l u m in a i r e su s p e n du . V ou s po u ve z ut [...]
-
Page 20
20 598-1219-05 Boîte électrique BRANCHEMENT DES FILS Not e : Le câb lag e d oit êt re conf orm e aux exig enc es du Co de can ad ien de l' éle ctr ici té et être da ns une can al isa tio n ou un autr e moy en ac cep tab le. Si vou s ave z des doute s sur la conv ena nce du syst ème , com mu niq uez av ec un él ect ric ien c omp éte n[...]
-
Page 21
21 598-1219-05 Lentille du capteur Écrou moleté ESSAIS 1. Mettre en circuit le disjoncteur et l’interrup - teur d’éclairage. No t e : Le capteur doit se réchauffer 1 1 / 2 mi- nute avant de pouvoir détecter le mouvement. Lorsque l’appareil est mis en circuit, attendre 1 1 / 2 minute. 2. Pour retirer le couvercle du détecteur de mou- vem[...]
-
Page 22
22 598-1219-05 Mouvement RÉGLAGE DE LA ZONE DE COUVERTURE L e c a p te ur d e c e d é t e c t eu r dé c è l e l e s m ou ve m e n t s e n ra i s on du pa ss a g e de la ch a le u r ( ch a le u r cor p o re l le ) da n s la zo ne d e c ou v er t u re . Ce p en d an t , vo us tr o u ve - re z ci -d e s so u s de s ex em p le s d’ ob j et s qu i[...]
-
Page 23
23 598-1219-05 DUAL B R IT E ® O N- T IME T E ST 1 5 10 MI N O FF 3 6 DU S K T O DA WN 2. Découpez la quan tité de ruban-mousse néces - saire pour coller le protecteur sur la lentille du capteur . 3. Retirez la pellicule protectrice d’un côté du ruban-mousse, puis collez le ruban à l’intérieur du protecteur de lentille. 4. Retirez la pe[...]
-
Page 24
24 598-1219-05 SYMPTÔME La lampe reste al - lumées continuel - lement. La lampe clignote. L ’éclairage ne de - meure pas allumé en mode Manuel. CAUSE POSSIBLE 1. La zone de couverture comprend une source de chaleur : évent, sortie de séchoir à linge ou surface brillante qui reète la chaleur . (Installez une section de protecteur sur la[...]