Hitachi CP-X615 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Hitachi CP-X615, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hitachi CP-X615 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Hitachi CP-X615. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Hitachi CP-X615 should contain:
- informations concerning technical data of Hitachi CP-X615
- name of the manufacturer and a year of construction of the Hitachi CP-X615 item
- rules of operation, control and maintenance of the Hitachi CP-X615 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hitachi CP-X615 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hitachi CP-X615, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hitachi service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hitachi CP-X615.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Hitachi CP-X615 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 Projector CP-X705/CP-X615 User's Manual – Oper ating Guide T echnical Example of computer signal Resolution (H x V) H. frequency (kHz) V . frequency (Hz) Rating Signal mode 720 x 400 37.9 85.0 VESA TEXT 640 x 480 31.5 59.9 VESA VGA (60Hz) 640 x 480 37.9 72.8 VESA VGA (72Hz) 640 x 480 37.5 75.0 VESA VGA (75Hz) 640 x 480 43.3 85.0 VESA VGA ([...]

  • Page 2

    2 Initial set signals Initial set signals The following signals are used for the initial settings. The signal timing of some computer models may be different. In such case, adjust the items V POSITION and H POSITION in the IMAGE menu. Back porch (B) Front porch (D) Back porch (b) Front porch (d) Di spl ay in ter val ( C) D isp lay i nte rva l ( c) [...]

  • Page 3

    3 D HDMI • T ype :Digital audio/video connector • Audio signal : Linear PCM (Sampling rate; 32/44.1/48 kHz) Connection to the ports A RGB 1, B RGB OUT D-sub 15pin mini shrink jack • Video signal: RGB separate, Analog, 0.7Vp-p, 75Ω terminated (positive) • H/V . sync. signal: TTL level (positive/negative) • Composite sync. signal: TTL leve[...]

  • Page 4

    4 VIDEO CONTROL AUDIO IN 1 AUDIO IN 2 AUDIO OUT RGB OUT RGB1 RGB2 HDMI R L R L AUDO IN 3 AUDIO IN 4 LAN C B /P B Y C R /P R B/C B /P B B/C R /P R G/Y H V USB REMOTE CONTROL Connection to the por ts (continued) 4 3 2 1 I VIDEO RCA jack • System: NTSC, P AL, SECAM, P AL-M, P AL-N, NTSC4.43 • 1.0±0.1Vp-p, 75Ω terminator H S-VIDEO Mini DIN 4pin j[...]

  • Page 5

    5 J AUDIO IN 1, K AUDIO IN 2 Ø3.5 stereo mini jack • 500 mV rms 47kΩ terminator AUDIO IN 3 L R, M L, AUDIO IN 4 N R, O L RCA jack x2 • 500 mV rms 47kΩ terminator P AUDIO OUT Ø3.5 stereo mini jack • 500 mV rms 1kΩ output impedance Q REMOTE CONTROL Ø3.5 stereo mini jack • T o be connected with the remote control that came with the pr[...]

  • Page 6

    6 VIDEO CONTROL AUDIO IN 1 AUDIO IN 2 AUDIO OUT RGB OUT RGB1 RGB2 HDMI R L R L AUDO IN 3 AUDIO IN 4 LAN C B /P B Y C R /P R B/C B /P B B/C R /P R G/Y H V USB REMOTE CONTROL Connection to the por ts (continued) T LAN RJ-45 jack Pin Signal Pin Signal Pin Signal 1 TX+ 4 - 7 - 2 TX- 5 - 8 - 3 RX+ 6 RX- 8 7 6 5 4 3 2 1 T S S USB USB B type jack Pin Sign[...]

  • Page 7

    7 RS-232C Communication RS-232C Communication 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 CONTROL port RS-232C cable (Cross) RS-232C port of the projector of the computer - (1) (1) CD RD (2) (2) RD TD (3) (3) TD - (4) (4) DTR GND (5) (5) GND - (6) (6) DSR RTS (7) (7) R TS CTS (8) (8) DTS - (9) (9) RI Connecting the cable 1. T urn off the projector and the [...]

  • Page 8

    8 RS-232C Communication (continued) Requesting projector status (Get command) (1) Send the request code Header + Command data (‘02H’+‘00H’+ type (2 bytes )+ ‘00H’ +‘00H’) from the computer to the projector . (2) The projector returns the response code ‘1DH’+ data (2 byt es) to the computer . Changing the projector settings (Set [...]

  • Page 9

    9 Command Control via the Network Communication Port The following two ports are assigned for the command control. TCP #23 TCP #9715 Command Control Settings Congure the following items form a web browser when command control is used. When the authentication setting is enabled, the following settings are required. Command Control via the Networ [...]

  • Page 10

    10 Command Control via the Networ k (continued) Command F or mat [TCP #23] 1. Protocol Consist of header (7 bytes) + command data (6 bytes) 2. Header BE + EF + 03 + 06 + 00 + CRC_low + CRC_high CRC_low: Lower byte of CRC ag for command data CRC_high: Upper byte of CRC ag for command data 3. Command data Command data chart byte_0 byte_1 byte_2[...]

  • Page 11

    1 1 Command Control via the Networ k (continued) Decreasing the projector setting value (Decrement command) (1) The PC sends the following decrement code to the projector . Header + Command data (‘05H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’) (2) The projector decreases the setting value on the above setting code. (3) The projector[...]

  • Page 12

    12 7. R epl y Data The connection ID (the data is same as the connection ID data on the sending data format) is attached to the Network control commands reply data. ACK reply: ‘06H’ + ‘xxH’ NAK reply: ‘15H’ + ‘xxH’ Error reply: ‘1CH’ + ‘xxxxH’ + ‘xxH’ Data reply: ‘1DH’ + ‘xxxxH’ + ‘xxH’ Projector busy reply: [...]

  • Page 13

    13 Names Operation T ype Header Command Data CRC Action T ype Setting Code Power Set TURN OFF BE EF 03 06 00 2A D3 01 00 00 60 00 00 TURN ON BE EF 03 06 00 BA D2 01 00 00 60 01 00 Get BE EF 03 06 00 19 D3 02 00 00 60 00 00 [Example return] 00 00 01 00 02 00 [Off] [On] [Cool down] Input Source Set RGB1 BE EF 03 06 00 FE D2 01 00 00 20 00 00 RGB2 BE [...]

  • Page 14

    14 RS-232C Communication / Netw or k command ta ble (continued) Names Operation T ype Header Command Data CRC Action T ype Setting Code GAMMA Set #1 DEFAUL T BE EF 03 06 00 07 E9 01 00 A1 30 20 00 #1 CUSTOM BE EF 03 06 00 07 FD 01 00 A1 30 10 00 #2 DEF AULT BE EF 03 06 00 97 E8 01 00 A1 30 21 00 #2 CUSTOM BE EF 03 06 00 97 FC 01 00 A1 30 1 1 00 #3 [...]

  • Page 15

    15 Names Operation T ype Header Command Data CRC Action T ype Setting Code COLOR TEMP Set HIGH BE EF 03 06 00 0B F5 01 00 B0 30 03 00 MID BE EF 03 06 00 9B F4 01 00 B0 30 02 00 LOW BE EF 03 06 00 6B F4 01 00 B0 30 01 00 Hi-BRIGHT -1 BE EF 03 06 00 3B F2 01 00 B0 30 08 00 Hi-BRIGHT -2 BE EF 03 06 00 AB F3 01 00 B0 30 09 00 Hi-BRIGHT -3 BE EF 03 06 0[...]

  • Page 16

    16 Names Operation T ype Header Command Data CRC Action T ype Setting Code MY MEMORY Load Set 1 BE EF 03 06 00 0E D7 01 00 14 20 00 00 2 BE EF 03 06 00 9E D6 01 00 14 20 01 00 3 BE EF 03 06 00 6E D6 01 00 14 20 02 00 4 BE EF 03 06 00 FE D7 01 00 14 20 03 00 MY MEMORY Save Set 1 BE EF 03 06 00 F2 D6 01 00 15 20 00 00 2 BE EF 03 06 00 62 D7 01 00 15 [...]

  • Page 17

    17 Names Operation T ype Header Command Data CRC Action T ype Setting Code COLOR SP ACE Set AUTO BE EF 03 06 00 0E 72 01 00 04 22 00 00 RGB BE EF 03 06 00 9E 73 01 00 04 22 01 00 SMPTE240 BE EF 03 06 00 6E 73 01 00 04 22 02 00 REC709 BE EF 03 06 00 FE 72 01 00 04 22 03 00 REC601 BE EF 03 06 00 CE 70 01 00 04 22 04 00 Get BE EF 03 06 00 3D 72 02 00 [...]

  • Page 18

    18 Names Operation T ype Header Command Data CRC Action T ype Setting Code FRAME LOCK RGB1 Set TURN OFF BE EF 03 06 00 3B 2C 01 00 50 30 00 00 TURN ON BE EF 03 06 00 AB C3 01 00 50 30 01 00 Get BE EF 03 06 00 08 C2 02 00 50 30 00 00 FRAME LOCK RGB2 Set TURN OFF BE EF 03 06 00 0B C3 01 00 54 30 00 00 TURN ON BE EF 03 06 00 9B 2C 01 00 54 30 01 00 Ge[...]

  • Page 19

    19 Names Operation T ype Header Command Data CRC Action T ype Setting Code VOLUME- COMPONENT Get BE EF 03 06 00 01 CC 02 00 65 20 00 00 Increment BE EF 03 06 00 67 CC 04 00 65 20 00 00 Decrement BE EF 03 06 00 B6 CD 05 00 65 20 00 00 TREBLE-RGB1 Get BE EF 03 06 00 0D C8 02 00 70 20 00 00 Increment BE EF 03 06 00 6B C8 04 00 70 20 00 00 Decrement BE[...]

  • Page 20

    20 RS-232C Communication / Netw or k command ta ble (continued) Names Operation T ype Header Command Data CRC Action T ype Setting Code SRS WOW – RGB1 Set TURN OFF BE EF 03 06 00 FE FF 01 00 90 20 00 00 MID BE EF 03 06 00 9E FE 01 00 90 20 02 00 HIGH BE EF 03 06 00 0E FF 01 00 90 20 03 00 Get BE EF 03 06 00 CD FF 02 00 90 20 00 00 SRS WOW – RGB[...]

  • Page 21

    21 RS-232C Communication / Netw or k command ta ble (continued) Names Operation T ype Header Command Data CRC Action T ype Setting Code AUDIO - RGB1 Set TURN OFF BE EF 03 06 00 FE DD 01 00 30 20 00 00 Audio1 BE EF 03 06 00 6E DC 01 00 30 20 01 00 Audio2 BE EF 03 06 00 9E DC 01 00 30 20 02 00 Audio3 BE EF 03 06 00 0E DD 01 00 30 20 03 00 Audio4 BE E[...]

  • Page 22

    22 RS-232C Communication / Netw or k command ta ble (continued) Names Operation T ype Header Command Data CRC Action T ype Setting Code REMOTE RECEIV . FRONT Set Off BE EF 03 06 00 FF 32 01 00 00 26 00 00 On BE EF 03 06 00 6F 33 01 00 00 26 01 00 Get BE EF 03 06 00 CC 32 02 00 00 26 00 00 REMOTE RECEIV . TOP Set Off BE EF 03 06 00 47 33 01 00 02 26[...]

  • Page 23

    23 Names Operation T ype Header Command Data CRC Action T ype Setting Code BLANK Set My Screen BE EF 03 06 00 FB CA 01 00 00 30 20 00 ORIGINAL BE EF 03 06 00 FB E2 01 00 00 30 40 00 BLUE BE EF 03 06 00 CB D3 01 00 00 30 03 00 WHITE BE EF 03 06 00 6B D0 01 00 00 30 05 00 BLACK BE EF 03 06 00 9B D0 01 00 00 30 06 00 Get BE EF 03 06 00 08 D3 02 00 00 [...]

  • Page 24

    24 Names Operation T ype Header Command Data CRC Action T ype Setting Code MY BUTTON-1 Set RGB1 BE EF 03 06 00 3A 33 01 00 00 36 00 00 RGB2 BE EF 03 06 00 FA 31 01 00 00 36 04 00 HDMI BE EF 03 06 00 CA 33 01 00 00 36 03 00 COMPONENT BE EF 03 06 00 6A 30 01 00 00 36 05 00 S-VIDEO BE EF 03 06 00 5A 32 01 00 00 36 02 00 VIDEO BE EF 03 06 00 AA 32 01 0[...]

  • Page 25

    25 Names Operation T ype Header Command Data CRC Action T ype Setting Code MAGNIFY Get BE EF 03 06 00 7C D2 02 00 07 30 00 00 Increment BE EF 03 06 00 1A D2 04 00 07 30 00 00 Decrement BE EF 03 06 00 CB D3 05 00 07 30 00 00 FREEZE Set NORMAL BE EF 03 06 00 83 D2 01 00 02 30 00 00 FREEZE BE EF 03 06 00 13 D3 01 00 02 30 01 00 Get BE EF 03 06 00 B0 D[...]