Go to page of
Similar user manuals
-
Dishwasher
Hobart FT950
28 pages 2.77 mb -
Dishwasher
Hobart 208-240/60/3
8 pages 0.91 mb -
Dishwasher
Hobart SR24H
16 pages 0.58 mb -
Dishwasher
Hobart LX18H
28 pages 1.04 mb -
Dishwasher
Hobart LXiH ML-130017
24 pages 1.53 mb -
Dishwasher
Hobart LX40H ML-104356
28 pages 1.04 mb -
Dishwasher
Hobart ML-138325
60 pages 11.58 mb -
Dishwasher
Hobart FASTRACK F-8018
8 pages 0.34 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Hobart FT1000-ER, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hobart FT1000-ER one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Hobart FT1000-ER. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Hobart FT1000-ER should contain:
- informations concerning technical data of Hobart FT1000-ER
- name of the manufacturer and a year of construction of the Hobart FT1000-ER item
- rules of operation, control and maintenance of the Hobart FT1000-ER item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hobart FT1000-ER alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hobart FT1000-ER, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hobart service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hobart FT1000-ER.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Hobart FT1000-ER item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
701 S. RIDGE A VENUE TROY , OHIO 45374-0001 937 332-3000 www .hobartcorp.com F47505 (October 2014) FT1000-SERIES DISHW ASHERS MODEL ML-130250 COVERS ALL OF THE FOLLOWING MODELS FT1000 FT1000-ER FT1000-ER-BD FT1000S FT1000S-ER FT1000S-ER-BD[...]
-
Page 2
– 2 – © HOBART 2008[...]
-
Page 3
– 3 – T ABLE OF CONTENTS NOTES FOR THE INST ALLERS ................................................... 4 How to Reduce the Clearance Height of the Control Box During Move-In ................ 4 UNP ACKING .................................................................. 6 Removing Each Section From Its Skid .....................................[...]
-
Page 4
– 4 – Installation and Care Of FT1000 SERIES DISHW ASHERS SA VE THESE INSTRUCTIONS GENERAL NOTES FOR THE INST ALLERS Read the entire manual befor e installing the machine . 1. Do not use a forklift to move or unskid machine sections. 2. Do not throw out any loose parts. These may be required for installation or operation. 3. Electrical Connecti[...]
-
Page 5
– 5 – 1. Remove the two shipping hinges from the side of the control box by removing the two 5/16-18 bolts from each bracket. 2. While two people are securely supporting the main control box, remove the four 5/16-18 nuts, lock washers, and washers from the inside of the shipping braces behind the control box. 3. Using at least two people, CAREF[...]
-
Page 6
– 6 – UNP ACKING Immediately after unpacking the dishwasher , check for possible shipping damage. If the machine is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery . Before installation, test the electrical service to make sure it agrees with the specicationsonthemachinedatap[...]
-
Page 7
– 7 – 7. Remove any packaging, tape, wire and bracing from each section. Remove all rear and lower panels. 8. V erify that shipping tape has been removed from all oats in each tank and that theoatsarefreetooperateproperly . NOTE: Do no throw out any loose parts. These may be r[...]
-
Page 8
– 8 – • Continue to level the center section front to back by removing the top panels and placing level across the top of the chambers on both ends of center section (Fig. 3). Fig. 3 ASSEMBL Y Rotating Control Box 90 Degrees The main control box is shipped with the upper and lower shipping hinges connected to the side of the control box. Remo[...]
-
Page 9
– 9 – TRIM EXCESS TAPE FROM INSIDE OF CHAMBER FLANGE FOLD FRONT EDGE OF FOAM TAPE 1/2 ” FRONT OF MACHINE Fig. 4 Fig. 5 Fig. 6 Apply foam tape to unload chamber section where the rear perimeter of the control box will be mounted.[...]
-
Page 10
– 10 – Attaching Control Box to Unload Section 1. For ease of control box installation, remove the detachable leg section on the front leg of the unload section where the control box will be mounted by removing the upper and lower ¼-20 hardware. This will allow the wires, which are preinstalled in the control box, to pass by the leg assembly f[...]
-
Page 11
– 1 1 – 8. Remove the two shipping braces from the end of the dual rinse section by removing the three 5/16 bolts and associated hardware from each brace. 9. Reinstall the detachable leg section removed in step 1. Positioning the Adjacent Load or Unload Sections Move the adjoining (load or unload) section to within several inches of the prepare[...]
-
Page 12
– 12 – SECURE VERTICAL FRAME CORNER POSTS AT TWO LOCATIONS Fig. 8 Installing the Curtain Bafes and Unload Air Bafe - T op of Chamber Flanges On prewash/wash section joint, install curtain bafe plate on wash side at the top of the chamber where sections are being joined using appropriate fast[...]
-
Page 13
– 13 – Fig. 9 On dual rinse/unload section joint, install the unload air bafe and two curtain hangers. The curtainhangers mounton totheair bafestuds wheretheyprotrude thru theupper front andrear corner chamberholes on thena[...]
-
Page 14
– 14 – CHAMBER FLANGE AND BOL T ASSEMBL Y A T EACH SECTION JOINT Description Qty . Bolt Size Assembly Order Instructions Short Bolt-Use except where long bolts or medium bolts are required 22 ¼-20 x 5/8” [Bolt, W asher] [W asher , Lockwasher , Nut] Use permagum on insides of washers on both sides of chamberanges. Medium Bolt-Use for cu[...]
-
Page 15
– 15 – PERMAGUM SADDLE JOINT PERMAGUM Fig. 13 Control Box Connections Refer to the electrical diagram stored inside the main control box door . After use, make sure that the diagram is placed inside the control box. Although each section is prewired, components in the load and unload sections must be electrically connected to the main control b[...]
-
Page 16
– 16 – Installing the Flowback Pipe (W ash to Prewash T anks) Installtheowbackpipebetweenthewashtankandtheprewashtank(Fig.14). Make sure the owback pipe is adequately lubricated with O-ring lube (not supplied). Make sure O-rings are in their proper places on the[...]
-
Page 17
– 17 – Relocating Master Drain to Load End (Only Machines Equipped with Auto Clean, Auto Delime, & the ASR Section) NOTE: If the dish machine is equipped with the Auto Clean and Auto Delime features, but does not contain the ASR section, then the Master Drain assembly must remain located at the unload end of the machine. With this congur[...]
-
Page 18
– 18 – For a R-L machine (steps 9-1 1): 9. Remove pipe (00-948761-00018) connecting the master drain and the nearest drain tee. 00-948761-00018 can be discarded. See Fig. 16. 00-948761-00018 Fig. 16 10. Remove rubber hose connected to drain tee located at load end of the unit. 1 1. Swap load end drain tee including drain ca[...]
-
Page 19
– 19 – 21. Loosen clamps securing rubber hoses to drain solenoid valve and rotate solenoid valve 180 degrees. Retighten clamps. 22. Attach rubber hoses to plastic drain tee and barbed tting on master drain assembly and tighten clamps. Ensure assembly matches correct diagram for direction of unit (Fig. 1[...]
-
Page 20
– 20 – 29. Remove two bolts, nuts, and washers attached to the load support bracket shipped with the machine (00-950109). See Fig. 19. TWO STUDS 00-950109 Bottom View (R-L Machine) Fig. 19 30. Attach load support bracket to load master drain platform using two studs located on the bottom of the load drain platform. Ensure bracket wraps over the[...]
-
Page 21
– 21 – DRAIN BACK PAN SLOPES TOWARD PREWASH TANK WASH SECTION LOWER TRACK Fig. 20 Fig. 21 Install the pan between the dual rinse and unload section ensuring that the pan slopes towards the dual rinse tank (Fig. 22). Secure the pan to the lower front and rear tracks using two ¼-20 x ½” bolts, lock washers, and?[...]
-
Page 22
– 22 – REAR PANEL TOP PANEL FRONT PANEL Fig. 24 2. Install one of the blower assemblies on top of the heater housing by lowering the blower assembly on an angle so that the front tabs hook underneath the notches on the top plate of the heater housing (Fig. 25 and 26). BLOWER ASSEMBLY NOTCH FRONT TAB FRONT TAB NOTCH Fig. 25 Fig. 26 3. Lower the [...]
-
Page 23
– 23 – 5. Repeat steps 2 thru 4 to install the second blower assembly . 6. Route both blower cables between the blower assemblies and the vertical enclosure panel to the rear of the control box. NOTE: Ensure that the cables are not routed on the side of the blowers where the air intake chamber openings are located. 7. Connect blower motor wires[...]
-
Page 24
– 24 – ELECTRICAL CONNECTION(S) Electrical and grounding connections must comply with applicable portions of the National Electrical Code (NFP A No. 70, latest edition) and/or other local electrical codes. Disconnect the electrical power to the machine and follow lockout/tagout procedures. There may be multiple circuits. Be sure all circuits ar[...]
-
Page 25
– 25 – Separate Electrical Connections Separate electrical connections in the main control box may be required for an optional electric blower dryer heater (when equipped) and for optional electric tank heaters (when equipped) unless equipped with optional circuit breakers. When equipped with an optional electric booster heater , a separate ele[...]
-
Page 26
– 26 – V ent Fan Control Machine electrical circuits can be used to switch a vent fan, supplied by others. On all models, the vent fan is ON when the main power switch is on. The two terminal connections for the vent fan control are both labeled VFC and are provided as a switchingcircuittocontroltheventfan. A location[...]
-
Page 27
– 27 – Final Rinse For FT1000 Base models, the required minimum hot water temperature for the nal rinse is 1 10° F when an electric or steam booster heater is supplied (same connectionpointfor ll).ForFT1000 EnergyRecovery models,theminimum cold water temp[...]
-
Page 28
– 28 – STEAM USAGE / REQUIREMENTS – POUNDS PER HOUR Model T ank Heat Booster 1 10 F Incoming W ater , 75 F Rise Dryer TOT AL T ank Heat & Booster TOT AL T ank Heat, Booster , & Dryer FT1000-Base 209 47 - 256 - FT1000S-Base 171 47 - 218 - FT1000-ER 213 42 - 255 - FT1000S-ER 171 42 - 213 - FT1000-ER-BD 213 42 30 255 285 FT1000S-ER-BD 17[...]
-
Page 29
– 29 – Auto Clean Hose Connections (When Equipped) Route Auto Clean hoses, located beneath unload section, to appropriate tank barbed connectionttings.Seebelowdiagramsforsolenoidvalvetotankdesignations. Right to Left FT1000 V alve Section Solonoid Designation 1 ASR 9 sol 2 PW/W Low 10 sol 3 PW 1 1 sol 4 W 12 sol[...]
-
Page 30
– 30 – Auto Clean Hose Part Numbers T o Each Chamber Machine Conguration ASR Prewash Upper Prewash/wash Lower W ash Upper Power Rinse Dual Rinse Standard w/ ASR 949942-1 949942-2 949942-3 949942-3 949942-3 949942-5 Standard w/o ASR Shorty w/ ASR 949942-2 949942-4 Shorty w/o ASR 949942-3 CONVEYOR ASSEMBL Y Prior to installing the conveyor , l[...]
-
Page 31
– 31 – Fig. 32 • T ie a rope to the rst conveyor rod. Feed the rope through the machine following thedesiredpathof theconveyorwiththeight linkspointingup. Theconveyor rollers must be fed between the upper roller guides and the tracks (Fig. 33). TRACKS[...]
-
Page 32
– 32 – • Remove the conveyor roller from one end of the last conveyor rod on the rst section. Then pull the conveyor rod out and save the roller and washers for re- assembly . T o join the sections, thread the rod back through the side bars and washerandthenthroughtheightlin[...]
-
Page 33
– 33 – Conveyor Offset Side Bar Conveyor offset side bars are supplied for use with the standard conveyors and are to be used, if necessary , when making the nal connection to join the two conveyor ends. The total length of all conveyor sections shipped may slightly exceed the optimal length requi[...]
-
Page 34
– 34 – Fig. 38 NOTE: The proper length of conveyor , when adjusted, will have the ight links close to engaging the load ngers at the load platform. It may be necessary to remove oneortwoconveyorrods(withrowsofightlinks)[...]
-
Page 35
– 35 – If the conveyor is tracking straight but travels closer to the front (door side) or toward the rear of the machine, then do the following: • If tracking closer to the front, tighten the adjusting bolt on the front take-up unit. • If tracking closer to the rear , tighten the adjusting bolt on the rear take-up unit. Run the conveyor fo[...]
-
Page 36
– 36 – Prewash, W ash, and Power Rinse Arms The upper and lower prewash, wash, and power rinse arms must be installed in their correct locations. T o install each of the upper or lower arms, slide manifolds on the supports toward the rear of the machine and ensure the tabs on the sides of the arms drop into the notches in the supports (Fig. 40)[...]
-
Page 37
– 37 – Automatic Soil Removal (ASR) Arms (When Equipped) ASR arms must be in their proper locations (Fig. 42). Fig. 42[...]
-
Page 38
– 38 – Bafe Settings The below diagram and chart outlines the standard bafe settings for eachof the machinecongurations. 5/6 2 3 4 7 1[...]
-
Page 39
– 39 – BAFFLE SETTINGS Machine T ype Bafe Setting Machine T ype Bafe Setting Standard Machine 1 Closed Shorty Machine 1 Closed 2 Open 2 Open 3 N/A 3 N/A 4 N/A 4 N/A 5 Closed 5 Closed 6 Closed 6 Closed 7 N/A 7 N/A Standard Machine with Blower Dryer 1 Closed Shorty Machine with Blower Dryer 1 Closed 2 Open 2 Closed 3 Closed 3 Closed 4 Open [...]
-
Page 40
– 40 – Lower T rim Panels (Front) and Rear Panels When installing the lower trim panels on the front of the machine, butt each panel end to end. With the bottom of the panel held out on a 45° angle (Fig. 43), hang the upper lip of the panel over the hooks located just below the doors (Fig. 44). Swing the bottom of the panel down and snap the l[...]
-
Page 41
– 41 – This may cause the dish limit arm to trip and stop the conveyor movement. If the conveyor stops for any reason during the 20 minute calibration period, the procedure should be rerun from the beginning to ensure proper calibration. After 20 minutes, unblock the photo detector . When the nal rinse output[...]
-