Go to page of
Similar user manuals
-
Portable Generator
Honda Automobiles EB5000X
43 pages 1.05 mb -
Portable Generator
Honda Automobiles EM1600X
36 pages 1.52 mb -
Portable Generator
Honda Automobiles EB5000i
92 pages 3.03 mb -
Portable Generator
Honda Automobiles EM3000c
55 pages 2.18 mb -
Portable Generator
Honda Automobiles EN5000
52 pages 1.9 mb -
Portable Generator
Honda Automobiles EG2500X
55 pages 1.5 mb -
Portable Generator
Honda Automobiles EG3500X
40 pages 1.41 mb -
Portable Generator
Honda Automobiles EB2200X
37 pages 1.37 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Honda Automobiles EM1600X, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honda Automobiles EM1600X one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Honda Automobiles EM1600X. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Honda Automobiles EM1600X should contain:
- informations concerning technical data of Honda Automobiles EM1600X
- name of the manufacturer and a year of construction of the Honda Automobiles EM1600X item
- rules of operation, control and maintenance of the Honda Automobiles EM1600X item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honda Automobiles EM1600X alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honda Automobiles EM1600X, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honda Automobiles service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honda Automobiles EM1600X.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Honda Automobiles EM1600X item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
©1983 Honda Motor Co., Ltd. — All Rights Reserved Owner's Manual GENERA T OR EM1600X • EM1800X • EM2200X[...]
-
Page 2
[...]
-
Page 3
Thank you for purchasing a Honda generator. This manual covers operation and maintenance of the EM1600X, 1800X and 2200X generators. All information in this publication is based on the latest product information available at the time of approval for printing. Honda Motor Co., Ltd reserves the right to make changes at any time without notice and wit[...]
-
Page 4
CONTENTS CONTENTS 1. 2. 3. 4. 5. 6. i: 9. GENERATOR SAFETY .................... L .............. 3 COMPONENT IDENTIFICATION ............................ 4 PRE-OPERATION CHECK ................................. 6 STARTING THE ENGINE .................................. 8 l High altitude operatioty .................................. 10 GENERATOR USE ...[...]
-
Page 5
1. GENERATOR SAFETY To ensure safe operation - l Place the generator at least 1 m (3 ft) away from buildings or other equip- ment during operation. l Operate the generator on a level surface. If the generator is tilted, fuel spillage may result. l Exhaust gas contains poisonous carbon monoxide. Never run the generator in an enclosed area. Be sure t[...]
-
Page 6
2. COMPONENT IDENTIFICATION FUEL GAUGE (Except EM1600XI VOLTAGE METER (Except EM1600X) ENGINE AIR CLEANER SWITCH - PILOT LAMP (Except EM1600X) GRIP BREAKER AGE ADJUSTMENT OIL ALERT / KNOB (Except EM1600XI LAMP / v DC TERMINALS DC CIA/CUIT OIL ~LLER CAP BREAKER[...]
-
Page 7
FUEL TANK CAP FUEL TANK -SPARK PLUG I EXHAUST OUTLET MUFFLER 5[...]
-
Page 8
3. PRE-OPERATION CHECK CAUTION: Be sure to check the generator on a level surface with the engine stopped. 1. Check the engine oil level. CAUTION: Engine oil is a major,factor affecting engine performance and service life. Non-detergent or vegetable oils are not recommended. Use Honda 4-stroke oil, or an equivalent high detergent, premium quality m[...]
-
Page 9
2. Check the fuel level Check the fuel gauge (EM1800X and EM2200X only), and refill the tank if the fuel level is low. Use low lead or unleaded automotive gasoline with a pump octane rating of 86 or higher. Never use an oil/gasoline mixture or dirty gasoline. Avoid getting dirt, dust or water in the fuel tank. Clean the fuel filler screen regularly[...]
-
Page 10
4. STARTING THE ENGINE (1) Disconnect any load from the DC terminals and make sure that the AC circuit breaker is in the OFF position. AC CIRCUIT BREAKER DC TERMINALS (2) Turn on the fuel valve. (3) Turn on the engine switch. ON 8[...]
-
Page 11
(4) Move the choke lever to the CLOSED position. (5) Pull the starter rope lightly until resistance is felt, then pull briskly. CAUTION: Do not allow the starter grip to snap back. Return it slowly by hand. NOTE: Make sure the pilot lamp comes on. If not, check the bulb filament. (6) Move the choke lever to the OPEN position as the engine warms up.[...]
-
Page 12
Oil Alert System Before the oil level in the crankcase can fall below a safe limit, the Oil Alert System will automatically shut off the engine. The Oil Alert Lamp will light when the recoil starter grip is pulled. To restart, add enough recommended engine oil to bring the oil level to the upper level mark on the dipstick (See page 6), and restart [...]
-
Page 13
5. GENERATOR USE m To prevent electrical shock from faulty appliances, the generator should be grounded. Connect a length of heavy wire between the generator’s ground terminal and an external ground source. GROUND TERMINAL CAUTION: l Limit operation requiring maximum poyver (1.6 KVA for the EM1600X; 1.8 KVA for the EM1800X and 2.2 KVA for the EM2[...]
-
Page 14
AC applications 1. Start the engine and make sure the pilot lamp comes on. If not, check the filament. 2. Switch on the AC Circuit Breaker. NOTE: Although voltage adjustment is usually not required, fine adjust- ments may be made by turning the voltage adjustment knob. Use the generator at the specified voltage (12OV). 3. Plug in the appliance; alw[...]
-
Page 15
DC application The DC terminals may be used for charging 12 volt automotive-type batteries only. m Batteries produce explosive gases. Keep sparks, flames, and cigarettes away. To prevent the possibility of creating a spark near the battery, connect charging cables first to the battery, then to the generator, and disconnect cables at the generator f[...]
-
Page 16
6. STOPPING THE ENGINE (1) (21 Turn off the AC circuit breaker and disconnect any charging leads at the DC terminals. Turn the engine switch to the OFF position. (3) Turn the fuel valve to the OFF position. - 14[...]
-
Page 17
7. MAINTENANCE The purpose of the maintenance and adjustment schedule is to keep the generator in the best operating condition. Inspect or service as scheduled in the table on the next page. B Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated, The exhaust con- tains poisonous car[...]
-
Page 18
Maintenance Schedule Air cleaner (Replace if necessary) NOTE (1) : Service more frequently when used in dusty areas. (2) : These items should be serviced by an authorized Honda dealer, unless the owner has the proper tools and is mechanically proficient, See the Honda Shop Manual.[...]
-
Page 19
Changing oil Drain the oil while the engine is still warm to assure rapid and complete draining. 1. Remove the drain plug and filler cap, and drain the oil. Retighten the plug securely. 2. Refill with the recommended oil (see page 6) and check the level. 01 L CAPACITY: 0.6 II (0.63 USqt) OIL FILLER OIL DRAIN PLUG CAUTION: Used motor oil may cause s[...]
-
Page 20
Air cleaner service A dirty air cleaner will restrict air flow to the carburetor, To prevent car- buretor malfunction, service the air cleaner regularly (page 16)). Service more frequently when operating the generator in extremely dusty areas. m Never use gasoline or low flash point solvents for cleaning the air cleaner element. A fire or explosion[...]
-
Page 21
Fuel filter service The filter prevents dirt or water which may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the filter should be cleaned. 1. Turn the fuel valve OFF. Remove the filter cup. 2. Clean the cup thoroughly. 3. Reassemble. Do not damage the rubber gasket. bw After installing the filter[...]
-
Page 22
Spark plug service Recommended spark plug: BPGES, BPRGES (NGK) W20EP-U, W20EPR-U (ND) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. 1. Remove the spark plug cap. 2. Clean any dirt from around the spark plug base. 3. Use the wrench supplied in the tool kit to remove the spark plug. PLUG WRENCH SPARK [...]
-
Page 23
6. Attach the plug washer and thread the plug in by hand to prevent cross threading. 7. After a new spark plug has been seated by hand, it should be tightened l/2 turn with a wrench to compress its washer. If a used plug is being reinstalled, it should only require l/8 to l/4 turn after being seated, CAUTION: l The spark plug must be securely tight[...]
-
Page 24
Spark arrester maintenance m If the generator has been running, the muffler will be.very hot. Allow it to cool before proceeding. CAUTION: The spark arrester must be serviced every 100 hours to maintain its efficiency. 1. Loosen the five 6 mm bolts to remove the muffler protedtor. PROTECTOR bolts 2. Remove the two 8 mm bolts at the exhaust pipe and[...]
-
Page 25
. 3. Use a brush to remove carbon deposits from the spark arrester screen. NOTE: Inspect the spark arrester screen for holes or tears. Replace if necessary. 4. Check the exhaust pipe gasket and replace if damaged. Reinstall the muffler and the protector. 23[...]
-
Page 26
8. TRANSPORTING/STORAGE B When transporting the generator, turn the engine switch OFF and keep the generator level to prevent fuel spillage. Fuel vapor or spilled fuel may ignite. Before storing the unit for an extended period: 1. Be sure the storage area is free of excessive humidity and dust. 2. Drain the fuel - a. With the fuel valve OFF, remove[...]
-
Page 27
9. TROUBLESHOOTING . When the engine will not start: Is there fuel in the tank? YES Refill the fuel tank. NO Turn the engine switch on. NO Turn the fuel valve on. in the engine? YES NO (The oil alert lamp goes on when pulling the starter grip) Add the recom- mended oil. led fuel around the the spark plug. spark plug. Spilled fuel 2) Remove the spar[...]
-
Page 28
No electricity at the AC receptacles: NO Turn the AC circuit breaker on. YES Check the electrical appliance or equip- ment for any defects NO DEFECTS Take the generator + to an authorized Honda dealer. DEFECTS - Replace the elect- rical appliance or equipment. * Take the electrical ) appliance or equip- ment to an elect- rical shop for repair. No e[...]
-
Page 29
Lb b B ” I I I WIR 1 ‘R I _I . A rs G 8 X V “r I I Lb LIGHT BLUE[...]
-
Page 30
[...]
-
Page 31
11. SPECIFICATIONS Dimensions Length x Width x Height 505 x 420 x 420 mm (19.9 x 16.5 x 16.5 in) Dry Weight EM 1600X, 1800X: 41.5 kg (91.5 lb) EM2200X : 44.0 kg (97.0 lb) Enoine Model Engine Type Displacement [Bore x Stroke] Compression Ratio Engine Speed Cooling System Ignition System Oil Capacity Fuel Tank Capacity Spark Plug Generator AC output [...]
-
Page 32
12. WARRANTY SERVICE Owner Satisfaction Your satisfaction and goodwill are important ‘to your dealer and to us. All Honda warranty details are explained in the Distributor’s Limited Warranty. Normally, any problems concerning the product will be handled by your dealer’s service department. If you have a warranty problem that has not been hand[...]
-
Page 33
MEMO 31[...]
-
Page 34
32[...]
-
Page 35
[...]
-
Page 36
Printed on Recycled Paper 75.2002.08 PRINTED IN U.S.A. P/N 31ZB1010 00X31-ZB1-0100 POM53284 KINKOS[...]