Honeywell 3355 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell 3355, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell 3355 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell 3355. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell 3355 should contain:
- informations concerning technical data of Honeywell 3355
- name of the manufacturer and a year of construction of the Honeywell 3355 item
- rules of operation, control and maintenance of the Honeywell 3355 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell 3355 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell 3355, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell 3355.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell 3355 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 69-1012 OWNER’S GUIDE MagicStat ® /3355 Programmable Thermostat by Honeywell W eekday/Weekend (5-day/ 2-day) Programmable Heat and/or Cool Low V oltage (20 to 30 V ac) Thermostat and Mounting Plate Model CT3355 69-1012[...]

  • Page 2

    2 69-1012 Welcome to the world of comfort and energy savings with your new Honeywell MagicStat® Programmable Thermostat. Y our new thermostat will automatically control the temperature in your home, keeping you comfortable while saving energy when pro- grammed according to the instructions in this manual. Direct any questions concerning the applic[...]

  • Page 3

    3 69-1012 T able of Contents Step 1: Prepare For Installation ..................................................................................................... 4 Step 2: Remove Old Thermostat ................................................................................................... 6 Step 3: Install Batteries ..........................[...]

  • Page 4

    4 69-1012 Step 1: Prepare for Installation ■ ■ Check T able 1 to make sure this thermostat is compatible with your system. If not, return to the retailer . For more information, call Honeywell Customer Assistance, toll-free 1-800-468-1502. T able 1. Compatibility Char t. Not compatible with any 120/240 volt circuit. a Compatible with 2-wire Hon[...]

  • Page 5

    5 69-1012 ■ ■ Acquire tools and items below as needed. Also purchase two AA alkaline batteries; we recom- mend Energizer® batteries. M878B CROSS-RECESSED SCREWDRIVER HAND OR POWER DRILL WITH 3/16 INCH DRILL BIT, IF NEEDED TO DRILL HOLES IN WALL WIRE CUTTER/STRIPPER OR SHARP KNIFE, IF NEEDED TO STRIP WIRES MASKING TAPE, IF  NE[...]

  • Page 6

    6 69-1012 Step 2: Remove Old Thermostat ■ ■ T est to make certain that your heating and cooling systems are working properly . If either does not work, contact your local heating/air conditioning dealer . T o avoid compressor damage, do not operate the cooling system when outdoor temperature is below 50 ° F (10 ° C). ■ ■ TURN OFF POWER to[...]

  • Page 7

    7 69-1012 Replacing a Clock Thermostat that has C or C1 Clock T erminals? If you are replacing a Honeywell Chronotherm® Thermostat, you can find one or two wires that go to the C or C1 clock terminals on the Chronotherm® Thermostat wiring wallplate. Do not allow them to touch, or you may damage your transformer . Disconnect the wires and wrap the[...]

  • Page 8

    8 69-1012 Step 3: Install Batteries IMPORT ANT Batteries must be installed for programming and oper ation of the thermostat and heating/cooling system. ■ ■ Purchase two AA alkaline batteries; non- alkaline batteries do not last as long, and can leak, causing damage to the thermostat or the wall surface. We recommend Energizer® batteries. ■ ?[...]

  • Page 9

    9 69-1012 indicator eventually stops flashing. bAt Lo stays on without flashing, indicating the thermostat and heating/cooling system have stopped working when the batteries are almost completely dead. After the batteries are completely dead, the bAt Lo indicator disappears, leaving a com- pletely blank display . Press down on the left ends of the [...]

  • Page 10

    10 69-1012 Step 4: Program Thermostat After the batteries are installed, the thermostat can be easily programmed in your hand, before it is installed on the wall. If you prefer to program the thermostat after it is installed on the wall, skip to page 18, and return later to this programming section. The following Personal Programming Chart (pages 1[...]

  • Page 11

    11 69-1012 to give the furnace a head start to heat the house before you arrive home. (Again, this is higher heating or lower for cooling.) SLEEP is the time period you can set for an energy-saving temperature while you are sleeping. (Again, this is lower for heating or higher for cooling. For more comfortable sleeping, some people choose not to ra[...]

  • Page 12

    12 69-1012 Personal Programming Chart Heating Pr ogram Weekdays Start Time Heating Temperature WAKE LEAVE RETURN SLEEP Weekends WAKE SLEEP W AKE and RETURN start times should include extra lead time based on outside temperature and furnace response time, to give your furnace a head start to heat the house. The temperatures cannot be set any higher [...]

  • Page 13

    13 69-1012 Weekdays Start Time Heating Temperature WAKE LEAVE RETURN SLEEP Weekends WAKE SLEEP Cooling Program W AKE and RETURN start times should include extra lead time based on outside temperature and furnace response time, to give your furnace a head start to heat the house. The temperatures cannot be set any higher than 88 ° F (31 ° C) or an[...]

  • Page 14

    14 69-1012 This guide can be used for programming your new thermostat. NOTE: Batteries are required for operation and programming. When inserting batteries, set system switch to OFF . Remove the battery door (on the thermostat left side) using a coin at the bottom. Follow instructions on pages 8 and 9. Set Current T ime/Day T o set the time, press [...]

  • Page 15

    15 69-1012 Press to program W AKE time and press to program WAKE temperature for Mon-Fri. Repeat sequence for LEA VE, RETURN, and SLEEP . Press until SA T SUN, WAKE and SET appear on the display . Press to program W AKE time and to program WAKE temperature for Sat-Sun. Repeat sequence for SLEEP . Cooling Program With system switch at COOL, follow t[...]

  • Page 16

    16 69-1012 A quick guide for operating or making changes follows: NOTE: System switch must be set to Heat or Cool to perform the following. T emporarily Change temperature for current period only — press ; TEMPORAR Y indicator shows on display; canceling itself at the next scheduled change, or to cancel sooner press . Hold a temperature indefinit[...]

  • Page 17

    17 69-1012 Check Programs— press , repeatedly to view each time and temperature; then press . Cancel a program— press , until program to cancel shows; then press . Check Usage — Press for length of time heat or air conditioning has been running today since midnight; press again for yesterday’s usage, press again for cumulative; press to cle[...]

  • Page 18

    18 69-1012 Step 5: Adjust Fan Operation Switch, as Required ■ ■ The thermostat fan operation switch, labeled FUEL SWITCH (see illustration on page 20) is factory-set in the F position. This is the correct setting for most systems. If your system is an electric heat system, set the switch to E. The E setting allows the fan to turn on immediately[...]

  • Page 19

    19 69-1012 First, turn in both screws completely , then adjust for system type: • W arm Air Furnace—Set at the Hot Water setting (A—out one turn, B—leave in). • Electric Furnace—Leave at the W arm Air Furnace setting (A—leave in, B—leave in). NOTE: This thermostat does not have a setting for steam/gravity air . Cycles would not be l[...]

  • Page 20

    20 69-1012 R Rc W Y G B D A C THERMOSTAT BACK M8796 DISPLAY ° F DISPLAY ° C C–IN C–OUT 1 TURN FOR HIGH EFFICIENCY FURNACE (90%+ AFUE) ADJUST: SCREW A–OUT ONE TURN SCREW B–IN FUEL SWITCH – F POSITION F E FUEL SWITCH WARM AIR FURNACE HOT WATER BOILER ELECTRIC  FURNACE A–IN  A–OUT 1 TURN A?[...]

  • Page 21

    21 69-1012 Step 7: Mount Thermostat Mounting Plate ■ ■ Position the mounting plate on the wall. Use a level to make sure the mounting plate is level. Use a pencil to mark the two mounting holes. ■ ■ Remove the mounting plate from the wall, and drill 3/16-inch holes in the wall (if drywall) as marked. For firmer material such as plaster or w[...]

  • Page 22

    22 69-1012 ■ ■ Level for appearance only; thermostat functions properly even when not level. T ighten the mounting screws. LEVEL M1714A[...]

  • Page 23

    23 69-1012 Step 8: Wire Thermostat T erminals NOTE: All wiring must comply with local codes and ordinances. If unsure about household wiring procedures, call your local heating/air conditioning contractor . Refer to masking tape labels you placed on the wires when you removed your old thermostat. ■ ■ Match the letter of your old thermostat wire[...]

  • Page 24

    24 69-1012 ■ ■ Loosen the terminal screws and slip each wire beneath its matching terminal. See illustration (lower right) for wire insertion technique. Securely tighten the terminals. ■ ■ Plug the hole in the wall with insulation to help prevent drafts from adversely affecting the thermostat operation. M1712A JUMPER (FACTORY- INSTALLED)[...]

  • Page 25

    25 69-1012 R Rc W Y G B D A C 2-WIRE HEAT-ONLY (JUMPER INTACT) M8793 L1 (HOT) L2 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 1 1 HEATING RELAY OR VALVE COIL JUMPER R Rc W Y G B D A C 4-WIRE HEAT/COOL (JUMPER INTACT) L1 (HOT) L2 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIR[...]

  • Page 26

    26 69-1012 R Rc W Y G B D A C 5-WIRE HEAT/COOL (JUMPER REMOVED) L1 (HOT) L2 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 1 M8795 L1 (HOT) L2 COOLING CONTACTOR COIL FAN RELAY HEATING RELAY OR VALVE COIL 1 1 R Rc W Y G B D A C 3-WIRE COOL-ONLY (JUMPER INTACT) L1 (HOT) L2 POWER SUPPLY. PROVIDE [...]

  • Page 27

    27 69-1012 Step 9: Mount Thermostat NOTE: T o remove the thermostat from the wall, first pull out at the bottom of the thermostat, then remove the top. M1734A B. PRESS LOWER EDGE  OF CASE TO LATCH. SWING OPEN COVER  TO CHECK  OPERATION. A. ENGAGE TABS AT TOP OF  THERMOSTAT AND MOUNTING PLATE. C.[...]

  • Page 28

    28 69-1012 Step 10: Check Thermostat Operation after Programming and Installing Heating Do not check heating system operation by jumpering thermostat terminals at the primary control such as the gas valve, zone valve, or oil burner control. This damages the thermostat, instead, jumper R and W wires at the thermostat. Move the system switch to HEA T[...]

  • Page 29

    29 69-1012 Cooling T o avoid possible compressor damage, do not operate the cooling system when outside temperature is below 50 ° F (10 ° C). See compres- sor manufacturer instructions for further information. NOTE: When cooling setting is changed, thermostat may delay up to five minutes before turning on the air conditioner . This delay protects[...]

  • Page 30

    30 69-1012 Step 1 1: Set Fan and System Switches First set the fan switch. F AN AUTO: Normal setting for most homes. A single-speed fan turns on automatically with the air conditioner or furnace. A two-speed fan usually runs on high with the air conditioner and on low with the furnace. Exception: If the fan operation switch on the back of the therm[...]

  • Page 31

    31 69-1012 Then set the system switch. COOL: The thermostat controls your air conditioning system. OFF: Both the heating and air conditioning systems are off. HEA T : The thermostat controls your heating system. Heat Cool Off Heat Cool Off M1703 Heat Cool Off M1707[...]

  • Page 32

    32 69-1012 T roubleshooting Guide If … Then… Display will not come on. ■ Set the system switch to OFF. Remove batteries. Insert backward for at least five seconds to reset thermostat. Replace batteries correctly. Display should come on. ■ Make sure batteries are fresh and installed correctly. ■ Gently clean battery contacts using a soft p[...]

  • Page 33

    33 69-1012 Heating will not come on. (Continued) ■ Jumper wires R and W. If heat does not come on, contact your heating dealer. ■ If display is blank or shows bAt Lo , install fresh batteries. ■ If temperature setting is higher than current temperature, and the display shows HEAT, contact Honeywell Customer Assistance at 1-800-468-1502. Cooli[...]

  • Page 34

    34 69-1012 Cooling will not come on. (Continued) ■ If temperature setting is lower than the current temperature, and the display shows COOL, move the system switch from COOL to OFF for ten minutes. After ten minutes, return the switch to the COOL position. If the air conditioner comes on, compressor may have reached its high limit temperature pro[...]

  • Page 35

    35 69-1012 The furnace cycles too frequently or the system cycle length is too short or too long. ■ Readjust system on-time according to instructions on pages 18 and 19. The thermostat's current setting does not match the display temperature to within ± 1 ° . ■ Check that the wiring hole in the wall behind the wallplate was plugged with [...]

  • Page 36

    36 69-1012 30% 28% 26% 24% 22% 20% 18% 16% 14% 12% 8% 6% 2% 10% 4% Minneapolis St. Paul Montreal Ottawa Toronto Buffalo Cleveland Milwaukee Edmonton Regina Winnipeg Calgary Moncton North Bay Quebec St. John's Halifax Vancouver Denver Des Moines  Omaha Salt Lake City Boston Chicago Detroit?[...]

  • Page 37

    37 69-1012[...]

  • Page 38

    38 69-1012[...]

  • Page 39

    39 69-1012 Limited One-Y ear Warranty Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer . If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shal[...]

  • Page 40

    40 69-1012 69-1012 6-96 J.S. Printed in U.S.A. Copyright © 1996 Honeywell Inc. All Rights Reserved ® U.S. Registered Trademark Helping You Control Your World Home and Building Control Honeywell Limited-Honeywell Limitée 155 Gordon Baker Road North York, Ontario M2H 2C9 Home and Building Control Honeywell Inc. Honeywell Plaza P.O. Box 524 Minneap[...]