Honeywell C7927A manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell C7927A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell C7927A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell C7927A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell C7927A should contain:
- informations concerning technical data of Honeywell C7927A
- name of the manufacturer and a year of construction of the Honeywell C7927A item
- rules of operation, control and maintenance of the Honeywell C7927A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell C7927A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell C7927A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell C7927A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell C7927A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    PRODUCT DATA 60- 2026- 11 ® U.S. Registered T rademark Copyright © 2001 Honeywell • All Rights Reserved C7027A, C7035, C7044A, C7927A Minipeeper® Ultraviolet Flame Detectors APPLICATION The C70 27A, C7035A, C7044A an d C7927A M inipeeper® Ultraviole t Flame De tectors detec t the ultra violet rad iation emitted b y combu stion fla mes. The fl[...]

  • Page 2

    C7027A, C70 35, C7044A, C7 927A MINIPEEPER® ULTRAVIOLE T FLAME DETECTORS 60-2026—1 1 2 ORDERING INFORMATION When purc hasing re placement a nd modernizatio n product s from your TR ADELINE® w holesal er or distri butor , refer to th e TRADELINE® Ca talog or price sheets for c omplete orde ring numb er . If you hav e additi onal ques tions, ne [...]

  • Page 3

    C7027A, C70 35, C7044A, C792 7A MINIPEEPER® ULTRAVIOLET FLAME DETECTORS 3 60-2026—1 1 C7035A Minip eeper® Ultraviolet Flame Detector: Flame D etection: End viewin g. Ambien t Operating T empera ture Ratings : 0°F to 250 °F (-18°C to +1 21°C), or -40°F to 2 50°F (-40°C to + 121°C), dependi ng on model. Maximum Pressure R ating: 5 p si (3[...]

  • Page 4

    C7027A, C70 35, C7044A, C7 927A MINIPEEPER® ULTRAVIOLE T FLAME DETECTORS 60-2026—1 1 4 Fig. 4. In stallatio n dimensions of C7927A 1016 (U.S .A. version ) and C7927A 1008 (Europe an version) in in. (mm). INSTALLATI ON When In stalling This Produc t... 1. Read t hese ins tructions carefully . Fai lure to fol low them co uld damage the product or [...]

  • Page 5

    C7027A, C70 35, C7044A, C792 7A MINIPEEPER® ULTRAVIOLET FLAME DETECTORS 5 60-2026—1 1 WARNING Explosion Ha zard and Ele ctrical Shock Ha zard. Can ca use serious injury , death or property damage. 1. The C 7027A, C 7035A , C704 4A and C7927 Fl ame Det ectors must be used with H oneywe ll fl ame safeguard controls (pri m aries , program mers, mul[...]

  • Page 6

    C7027A, C70 35, C7044A, C7 927A MINIPEEPER® ULTRAVIOLE T FLAME DETECTORS 60-2026—1 1 6 Mounting a C7027A, C7927 or C7035A Locate the Sight Pipe The loc ation of th e sight p ipe is the most cri tical p art of the inst allation. A blac k iron pipe is r ecommen ded. Do not use a stai nless steel or galva nized pipe be cause its in ternal surfac e [...]

  • Page 7

    C7027A, C70 35, C7044A, C792 7A MINIPEEPER® ULTRAVIOLET FLAME DETECTORS 7 60-2026—1 1 Swivel Mount T o facilit ate proper sig hting of t he flame, a swivel m ount (part n o. 1 18367A) is availabl e. The sw ivel mo unt will re quire a 3/4 to 1/2 in. reduce r and a 1/2 in. clos e nipple to mount a C7027 A, or a 1 in. pipe at least 2-1 /2 in. [63 .[...]

  • Page 8

    C7027A, C70 35, C7044A, C7 927A MINIPEEPER® ULTRAVIOLE T FLAME DETECTORS 60-2026—1 1 8 Fig. 8. Moun ting C7044A Dete ctor on blast tu be. The C7 044 is m ounted in a 29/32 in . (23.0 mm) hole in the blast tu be. The m ounting b racket is fastene d to the blast tu be with 2 screws on 1-27/64 in . (36.1 mm ) centers. The mo unting brac ket is desi[...]

  • Page 9

    C7027A, C70 35, C7044A, C792 7A MINIPEEPER® ULTRAVIOLET FLAME DETECTORS 9 60-2026—1 1 g. T he scan ner wi res sh ould re main se parated a minimum of two in . (51 mm) from other line volt age wire s in the main cont rol panel to t he f lame safeg uard de vice. 3. A void ins tallat ion cons iderati ons that c an influe nce detecto r operation and[...]

  • Page 10

    C7027A, C70 35, C7044A, C7 927A MINIPEEPER® ULTRAVIOLE T FLAME DETECTORS 60-2026—1 1 10 Fig. 10. M easuring microamp flame signa l. The R7 749B and R78 49A,B Ampli fiers use d with the Honeyw ell BCS 7700 and 7800 SERIES cont rols, respect ively , have a dc voltage flame s ignal outp ut. For the R 7749B Amplifie r , a volt-ohmm eter with a zero [...]

  • Page 11

    1 1 60-2026—1 1 a Currentl y obsolete. Ignition Spark Res ponse Test T est to be su re that ignition s par k is not actuating the flame relay (us ually 2K) or fl ame LED in the flame safegu ard control. 1. Close the pilot and main burner manual fuel shutof f valve s. 2. Conne ct the app ropriate me ter to the f lame safeguard control amplifier . [...]

  • Page 12

    60-2026—1 1 G .R. Rev . 07-01 www . honeywell.com/bbc Home and Building Control H ome and Building Control Honeywell Honeywell Limited- Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. C7027A, C7[...]