Honeywell F100 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell F100, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell F100 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell F100. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell F100 should contain:
- informations concerning technical data of Honeywell F100
- name of the manufacturer and a year of construction of the Honeywell F100 item
- rules of operation, control and maintenance of the Honeywell F100 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell F100 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell F100, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell F100.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell F100 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    GETTING ST ARTED MOUNTING INCLUDED IN THIS BOX 68-0239EF-05 APPENDICES T ools needed to install Enhanced Air Cleaner Standard screwdriver Phillips screwdriver Metal cutter Drill Duct Sealant Replacement Air Filters Filter Size (in.) Part Number 12.5 x 20 FC100A1052 16 x 25 FC100A1029 16 x 20 FC100A1003 20 x 25 FC100A1037 20 x 20 FC100A101 1 SPECIFI[...]

  • Page 2

    [...]

  • Page 3

    GETTING ST ARTED MOUNTING SPECIFICA TIONS F100 Medi a Air Cleaner NEED HELP? For assistance with this product please visit http://yourhome .honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502. Read and save these instructions. ® U.S. Registered T rademark. Patents pending. Copyright © 201 1 Honeywell International Inc. All r[...]

  • Page 4

    GETTING ST ARTED Congratulations for selecting the Honeywell Media Air Cleaner for your home comfort system! The F100 Media Air Cleaner captures and removes a signicant amount of the air-borne particles from the air circulated through the high-efciency pleated media lter . The Media Air Cleaner easily mounts in any position within the retu[...]

  • Page 5

    GETTING ST ARTED Application Considerations The Honeywell F100 Media Air Cleaner is designed to work with gas, oil, and electric forced warm air furnaces and with compressor cooling. It can also be used with heat pumps if the lter is changed regularly to prevent excessive pressure drop. The F100 Media Air Cleaner is not recommended for applicati[...]

  • Page 6

    GETTING ST ARTED T ransitions For most efcient air cleaning, spread airow evenly across the face of the media. If the duct is a different size than the media air lter cabinet, gradual transitions are required. Follow these guidelines when fabricating: • Use gradual transitions to reduce air turbulence and increase efciency . • Use n[...]

  • Page 7

    GETTING ST ARTED Important Installation Requirements Personal Safety • Wear safety glasses while installing the unit. • Do not cut into any air conditioning or electrical line. • Follow professional safety standards and all local codes for plumbing, electrical, and mechanical considerations. Before Mounting • Using the gure on the cover [...]

  • Page 8

    MOUNTING The Media Air Cleaner mounts in any position within the return air duct, usually next to the furnace blower compartment, but the arrow on the cartridge must point in the same direction as the airow . See Figs. 3-10 for proper location of the media air cleaner for a variety of furnace installations. NOTE: The media air cleaner cabinet is[...]

  • Page 9

    MOUNTING M941A M942B Fig. 3.Highboy furnace, with closet installation. Media air cleaner is mounted vertically on furnace between furnace and louvered return air opening in closet door . Fig. 4. Lowboy furnace, with media air cleaner mounted horizontally in return plenum just above furnace and opposite heating plenum. F100 Medi a Air Cleaner 68-023[...]

  • Page 10

    MOUNTING M943B M944B Fig. 5. Counterow furnace, with media air cleaner mounted horizontally in return duct or plenum just above furnace. Fig. 6. Central fan installation, with media air cleaner mounted horizontally in central return duct. M945B M946B Fig. 7. Horizontal furnace, with media air lter mounted vertically in return duct near furnac[...]

  • Page 11

    MOUNTING The following procedure describes a typical side installation on an existing highboy furnace (Fig. 1). Alternate procedures are noted as appropriate. Other changes in installation procedures may be necessary to complete your installation. NOTE: Before starting the installation, remove and discard the existing furnace lter (if used). Tho[...]

  • Page 12

    MOUNTING Visually check the installation and make sure that: • Airflow is in the direction of the arrow on the media air filter cartridge . • T urning vanes and transitions, if used, ar e properly installed. • Joints in sheetmetal between media air filter and furnace are sealed. • All sheetmetal connections are complete . •[...]

  • Page 13

    SPECIFICA TIONS Capacity And Pressure Drop Initial Pressure Drop: 0.23 in. wc at 492 fpm. T emperature Rating -40° to +140°F (-40° to +60°C) Mounting Mounts in any position in the return air duct, usually next to the furnace blower compartment. Cabinet is sturdy enough to support weight of a residential furnace and evaporator coil. Approvals Un[...]

  • Page 14

    Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden V alley , MN 55422 http://yourhome.honeywell.com ® U.S. Registered T rademark. © 2011 Honeywell International Inc. 68-0239EF—05 M.S. 07-11 Printed in U.S.A.[...]

  • Page 15

    POUR COMMENCER MONT AGE CARACTÉRISTIQUES TECHNIQUES INCLUS DANS LA BOÎTE 68-0239EF-05 Épurat eur d’ air à f ibre s F 1 0 0 •  PROFESSIONAL INST ALLA TION GUIDE . • GUIDE D’INST ALLA TION PROFESSIONNELLE . Outils requis pour installer l’épurateur d’air amélioré T ournevis normal T ournevis cruciforme Cisailles à tôle Perce[...]

  • Page 16

    [...]

  • Page 17

    POUR COMMENCER MONT AGE CARACTÉRISTIQUES TECHNIQUES Épurateurd’airàbresF100 BESOIN D’AIDE? Pour obtenir de l’aide sur ce produit, prière de visiter le site http://yourhome .honeywell.com ou d’appeler le service d’assistance à la clientèle de Honeywell au 1-800-468-1502. Lire et conserver ces instructions. ® Marque de[...]

  • Page 18

    POUR COMMENCER Félicitations pour votre choix de l’épurateur d’air à bres Honeywell pour votre système de confort d’intérieur! L ’épurateur d’air à bres F100 capture et retire une quantité considérable de particules contenues dans l’air circulant par le ltre à bres à plis haute efcacité. L ’épurateur d’ai[...]

  • Page 19

    POUR COMMENCER Considérations relatives à l’application L ’épurateur d’air à bres F100 de Honeywell est conçu pour fonctionner avec les appareils de chauffage à gaz, mazout, électrique et air pulsé et les systèmes de refroidissement par compresseur . Il peut aussi être utilisé avec des thermopompes uniquement si le ltre est r[...]

  • Page 20

    POUR COMMENCER T ransitions Pour un nettoyage de l’air optimal, le débit d’air doit passer uniformément sur la face du ltre. Si la taille de la gaine est différente de l’armoire du ltre à bres, des transitions graduelles sont requises. Suivre ces instructions lors de la fabrication : • Utiliser des transitions graduelles pour r[...]

  • Page 21

    POUR COMMENCER Exigences d’installation importantes Sécurité personnelle • Porter des lunettes de protection lors de l’installation de l’unité. • S’assurer de ne pas entailler les ls électriques ou les gaines de climatisation. • Respecter les normes de sécurité professionnelles et les codes de plomberie et d’électricité e[...]

  • Page 22

    MONT AGE L ’épurateur d’air à bres se monte dans n’importe quelle position dans la gaine d’air de retour , en général près du compartiment de la soufante de l’appareil de chauffage, mais la èche du ltre doit pointer dans la direction du débit d’air . V oir les Fig. 3-10 pour l’emplacement de l’épurateur d’air ?[...]

  • Page 23

    MONT AGE M941A M942B Fig. 3.Appareil de chauffage superposé avec installation dans un placard. L ’épurateur d’air à bres se monter verticalement sur l’appareil de chauffage entre ce dernier et l’ouverture de l’air de retour à volets de la porte du placard. Fig. 4. Appareil de chauffage juxtaposé avec épurateur d’air à bres [...]

  • Page 24

    MONT AGE M943B M944B Fig. 5. Appareil de chauffage à contrecourant avec épurateur d’air à bres monté horizontalement dans la gaine de retour ou le plénum juste au-dessus de l’appareil de chauffage. Fig. 6. Installation de ventilation centrale avec épurateur d’air à bres monté horizontalement dans la gaine de retour centrale. M94[...]

  • Page 25

    MONT AGE La procédure suivante décrit une installation latérale typique sur un appareil de chauffage superposé existant (Fig. 1). Les autres procédures sont indiquées selon le besoin. D’autres modications des procédures d’installation peuvent être nécessaires pour terminer l’installation. REMARQUE : Avant de commencer l’installa[...]

  • Page 26

    MONT AGE ÉT APE 7 : Installation du ltre Insérer le ltre dans l’armoire en s’assurant que la èche du ltre pointe dans la direction du débit d’air . Replacer la porte d’accès. Insérer la languette au bas de la porte dans la fente de l’armoire. Faire pivoter la porte pour la fermer et appuyer dessus pour l’enclencher en [...]

  • Page 27

    CARACTÉRISTIQUES TECHNIQUES Capacité et chute de pression Chute de pression initiale : 0,23 po c.e. à 492 pi/min T empérature nominale -40 °C à 60 °C (-40 °F à 140 °F) Montage Montage dans toutes les positions de la gaine d’air de retour , généralement près du compartiment de la soufante de l’appareil de chauffage. L ’armoire [...]

  • Page 28

    Solutions de régulation et d'automatisation Honeywell International Inc. 1985 Douglas Drive North Golden V alley , MN 55422 http://yourhome.honeywell.com ® Marque de commerce déposée aux É.-U. © 2011 Honeywell International Inc. 68-0239EF—05 M.S. 07-11 Imprimé aux États-Unis.[...]