Go to page of
Similar user manuals
-
Air Cleaner
Honeywell F118
12 pages 0.2 mb -
Air Cleaner
Honeywell 50100
24 pages 0.82 mb -
Air Cleaner
Honeywell HHT-100
20 pages 1.68 mb -
Air Cleaner
Honeywell F111 Series 3
12 pages 0.6 mb -
Air Cleaner
Honeywell F50E
30 pages 0.49 mb -
Air Cleaner
Honeywell F113C
8 pages 0.17 mb -
Air Cleaner
Honeywell 13350
8 pages 0.5 mb -
Air Cleaner
Honeywell F116
16 pages 0.38 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell F300E, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell F300E one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Honeywell F300E. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Honeywell F300E should contain:
- informations concerning technical data of Honeywell F300E
- name of the manufacturer and a year of construction of the Honeywell F300E item
- rules of operation, control and maintenance of the Honeywell F300E item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell F300E alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell F300E, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell F300E.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell F300E item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
F300E Electronic Air Cleaner PRODUCT DA T A ® U.S. Registered Trademark Copyright © 2000 Honeywell • All Rights Reserved APPLICA TION The F300E Electronic Air Cleaner is mounted in the retur n air duct of a forced air heating, cooling, or v entilating system. It captures a significant amount of the airborne par ticles 0.3 microns and larger fro[...]
-
Page 2
F300E ELECTRONIC AIR CLEANER 68-0240-1 2 SPECIFICA TIONS IMPORT ANT The specifications giv en in this publication do not include nor mal manuf acturing toler ances . Theref ore, this unit may not e xactly match the listed specifications. This product is tested and calibrated under closely controlled conditions, and some minor differences in perf or[...]
-
Page 3
F300E ELECTR ONIC AIR CLEANER 68-0240-1 3 Fig. 1. Air c leaner efficiency and pressure drop at v arious airflow rates. Weight: See T able 2. Dimensions: See Fig. 2. Underwriters Laboratories Inc. Listed: File No . E30954. Accessories: 203365A Conv ersion Kit for changing 120V , 60 Hz pow er supply to 240V , 60 Hz or 220/240, 50 Hz. W8600F Air Clean[...]
-
Page 4
F300E ELECTRONIC AIR CLEANER 68-0240-1 4 Fig. 2. Installation dimensions of Electr onic Air Cleaner in in. (mm). PLANNING THE INST ALLA TION Application The F300E Electronic Air Cleaner is used in a forced air heating, cooling, or ventilating system. It removes airborne par ticles from the air circulated through it. All models hav e an inter nal ai[...]
-
Page 5
F300E ELECTR ONIC AIR CLEANER 68-0240-1 5 1. Mount it as far as possib le upstream from the air cleaner . 2. Install a standard disposable furnace filter between the humidifier and the air cleaner to trap water droplets and hard water salts . 3. F requently clean the air cleaner to prev ent a hard water salt b uildup. NO TE : The volume of w ater t[...]
-
Page 6
F300E ELECTRONIC AIR CLEANER 68-0240-1 6 Fig. 3. Mounting positions with v ariety of furnace installations. Determine Duct Design Requirements The air cleaner is adaptable to all ne w or existing f orced air heating, cooling and ventilating systems used in residential applications. T ransitions, turning vanes, or offsets ma y be needed in some appl[...]
-
Page 7
F300E ELECTR ONIC AIR CLEANER 68-0240-1 7 ❑ Place bloc ks under the cabinet so the unit is firmly suppor ted and lev el. The 5/8 in. (16 mm) mounting foot on the cabinet hinge plate provides the minimum clear ance required f or the access door hinge. ❑ Attach the cabinet securely to the furnace. The unit can be attached directly , as shown, or [...]
-
Page 8
F300E ELECTRONIC AIR CLEANER 68-0240-1 8 Fig. 7. Connect ductw ork to air cleaner . Note turning vanes. Locking plier s hold duct to air cleaner cabinet during installation. Install Optional W8600F Air Cleaner Monitor The W8600F Air Cleaner Monitor is an option a v ailable for use with the F300E. The W8600F function indicator panel has four liquid [...]
-
Page 9
F300E ELECTR ONIC AIR CLEANER 68-0240-1 9 Select W ash Frequency Use the W8600F DIP switches to prog ram the time between SER VICE indications. Be sure to select the setting according to the conditions of the home. F actors to consider include the duty cycle of the EAC , the number of people and pets, and activities such as woodworking and other cr[...]
-
Page 10
F300E ELECTRONIC AIR CLEANER 68-0240-1 10 10. Plug the driver board assemb ly into the J1 power supply connector . 11. Replace the power supply bo x cov er . 12. Connect the three wires from the W8600F to the EAC terminals 1, 3 and 4. See Fig 12. The W8600A function indicator panel has four liquid crystal displa y (LCD) arrow indicators that point [...]
-
Page 11
F300E ELECTR ONIC AIR CLEANER 68-0240-1 11 Fig. 16. P osition of cell ke y determines orientation of cell (arro w on key must point do wnstream). 4. Tighten the screw into the ne w hole. 5. Inser t the electronic cell. The ioniz er section will now be on the air-entering (upstream) side of the cabinet. Attach Cell Handle(s) The cell handles must be[...]
-
Page 12
F300E ELECTRONIC AIR CLEANER 68-0240-1 12 P3 P4 P1 P2 J3 BLACK W4 W2 W1 W3 AIRFLOW SWITCH BOARD ORANGE GRAY VIOLET BLACK 1 INTERLOCK SWITCH. 2 SHORTING BAR. 3 AIRFLOW SWITCH DISABLE JUMPER. 4 OPTIONAL W8600F AIR CLEANER MONITOR. DRIVER BOARD AND CABLE PROVIDED WITH W8600F. 5 NEON LIGHT. M11975 POWER SUPPLY 2 5 BLACK 4 BLACK BLACK BROWN BLACK BLACK [...]
-
Page 13
F300E ELECTR ONIC AIR CLEANER 68-0240-1 13 • Outside air , if used, is mix ed with retur n air or heated, as necessary , bef ore it can reach the air cleaner . • Airflow arro ws on the electronic cell point downstream. • Prefilter is on the upstream side of the cell. • Cell handle f aces outward. • Electronic cell and prefilter are clean [...]
-
Page 14
F300E ELECTRONIC AIR CLEANER 68-0240-1 14 NO TE : T o let the heating or air conditioning system operate normally while the cell(s) are being washed, simply turn off the air cleaner switch. V acuum the prefilter or brush, or soak it in a tub . Do not wash the prefilter in the dishwasher or car w ash. Automatic Dishwasher CA UTION Burn Hazard. Can c[...]
-
Page 15
F300E ELECTR ONIC AIR CLEANER 68-0240-1 15 Fig. 23. Replacing an ionizer wire . COLLECTOR TERMINAL COLLECTOR TERMINAL IONIZER TERMINAL M6155 5. Rinse the cell(s) and prefilter(s) with a hard spra y of very hot water; rinse the tub clean, then fill the tub with clean hot water and soak f or 5 to 15 minutes. Rinse until the water draining from the ce[...]
-
Page 16
F300E ELECTRONIC AIR CLEANER 68-0240-1 16 Modification to Reduce Ozone Odor W ARNING Electric Shock Hazar d. Can cause personal injury . Alwa ys disconnect power and open the access door before opening the po wer supply cov er. The electronic air cleaner generates a small amount of ozone in normal operation. During the first week or two of operatio[...]
-
Page 17
F300E ELECTR ONIC AIR CLEANER 68-0240-1 17 Fig. 25. Move J5 shor ting bar to reduce ozone production about 20 to 25 percent. P3 P4 P1 P2 M15099 J3 J4 J5 SHUNT IN OZONE REDUCTION POSITION J5 IN NORMAL POSITION J1 J5 E4 E3 E1 E5 E6 E2[...]
-
Page 18
F300E ELECTRONIC AIR CLEANER 68-0240-1 18 REPLACEMENT PARTS/EXPLODED VIEW Nominal Return Air Opening No. Description 16 x 20 in. (406 x 508 mm) 16 x 25 in. (406 x 635 mm) 20 x 20 in. (508 x 508 mm) 20 x 25 in. (508 x 635 mm) 1 Access Door 32004876-004 32004876-004 32004876-003 32004876-003 2 Electronic Cell FC37A1114 (2) FC37A1130 (2) FC37A1049 (2)[...]
-
Page 19
F300E ELECTR ONIC AIR CLEANER 68-0240-1 19 Fig. 27. Components of the Electronic Air Cleaner (2-cell model shown). M14740 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20[...]
-
Page 20
F300E ELECTRONIC AIR CLEANER 68-0240-1 20 Parts and Accessories Not Illustrated ELECTRICAL TROUBLESHOOTING W ARNING Electric Shock Hazar d. Can cause personal injury or equipment damage. The follo wing procedures expose hazardous liv e par ts. Disconnect from power betw een checks and proceed carefully . These instructions are for use b y qualified[...]
-
Page 21
F300E ELECTR ONIC AIR CLEANER 68-0240-1 21 TR OUBLE SHOOTING AIR CLEANERS WITH PERFORMANCE INDICA T OR. Fig. 28. T roub leshooting air cleaner s. MAKE SURE ELECTRONIC CELLS ARE CLEAN, DRY, AND CORRECTLY INSTALLED. MAKE SURE PREFILTERS ARE IN CABINET SLOT FARTHEST FROM FURNACE OR AIR HANDLER. TURN ON ELECTRONIC AIR CLEANER AND SYSTEM FAN. OFF START [...]
-
Page 22
F300E ELECTRONIC AIR CLEANER 68-0240-1 22[...]
-
Page 23
F300E ELECTR ONIC AIR CLEANER 68-0240-1 23 YEAR ELECTRONIC AIR CLEANER WASH REMINDER SCHEDULE , M982A JF M A M J J AS O N D INSTALLATION DATE:[...]
-
Page 24
Home and Building Control Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 68-0240-1 G.H. Rev . 9-00 Home and Building Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. www .hone ywell.com ZAP TRAP UL TRA VIOLET[...]