Go to page of
Similar user manuals
-
Stud Sensor
Honeywell CTS-20
4 pages 0.36 mb -
Stud Sensor
Honeywell G
8 pages 0.21 mb -
Stud Sensor
Honeywell CTP-20
4 pages 0.36 mb -
Stud Sensor
Honeywell H
8 pages 0.21 mb -
Stud Sensor
Honeywell SC2000
174 pages 3.95 mb -
Stud Sensor
Honeywell C7089
12 pages 0.5 mb -
Stud Sensor
Honeywell IS4825
48 pages 0.95 mb -
Stud Sensor
Honeywell C7400S
4 pages 0.71 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell H, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell H one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Honeywell H. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Honeywell H should contain:
- informations concerning technical data of Honeywell H
- name of the manufacturer and a year of construction of the Honeywell H item
- rules of operation, control and maintenance of the Honeywell H item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell H alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell H, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell H.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell H item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
® U.S. Re gistered T radem ark Copyright © 2001 Honeywel l • All Rig hts Reserved INSTALLATION I NSTRUCTIONS 62- 0179 T7047C,G ,H Remote S pace Sens ors APPLICATION The T7047 Remot e Spa ce Sen sors are used in Serie s 70 Control Systems to provi de modulat ing space temperature control. SPECIFICATIONS IMPO RTAN T The specificat ions given in t[...]
-
Page 2
T7047C ,G,H RE MOTE SP ACE SE NSOR S 62-0179 2 Setpoint A djustment (T7047C,G only ): Remot e setpoint de vice such as S963B , T7067B , T7080B . Sensor Re sistance: For the f ollowin g negati ve tempe rature coefficient (NTC ) devices, resistance de creases as temperatu re increases (see Fig . 3 through 6): T7047C1009 : 1695 ohms nom inal at 75°F [...]
-
Page 3
T7047C, G,H REM OTE S PACE SEN SORS 3 62-0179 INSTALLATION When Installing th is Product... 1. Read these instruct ions carefully . Failure to follow them could damage the p roduct or cause a hazardous condit ion. 2. Check the r atings give n in th e instructions and o n the produc t to make sure the product is suit able for your applicati on. 3. I[...]
-
Page 4
T7047C ,G,H RE MOTE SP ACE SE NSOR S 62-0179 4 Fig. 6. T7047G 1000 Rem ote S ensor res istance change with cha nge in temper ature. Fig. 7. T7047H 1008 Remote Sen sor resi stance change with cha nge in temper ature. Wirin g IMPORTANT All wiring must agr ee with applicabl e codes, ordinances and reg ulations. Fig. 8 through 16 sho w schematics and t[...]
-
Page 5
T7047C, G,H REM OTE S PACE SEN SORS 5 62-0179 Fig. 12. T704 7C1025 us ed as a remote sensor with T7 067B Thermosta t. Fig. 13. Four T7047C1025 S ensors provi ding a temperatur e-averagi ng network f or a T7300/Q73 00 Thermost at/Subbase. Fig. 14. T wo T7047G1000 Sensors provi ding a temperatur e-averagi ng network f or a T7300/Q7 300 Thermost at/Su[...]
-
Page 6
T7047C ,G,H RE MOTE SP ACE SE NSOR S 62-0179 6 Fig. 17. T704 7C1082 us ed as a remote sensor with T7 080B Thermosta t. 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. TERMINALS 3, 7 AND 8 ARE ALL EQUIVALENT COMMON TERMINALS. RESISTOR AND TIME SWITCH IN SERIES BETWEEN TERMINALS 5-7. SEE FIG. 6, PAGE 5. 2 M5355 3 L1 (HOT[...]
-
Page 7
7 62-0179 T7047C, G,H REM OTE S PACE SEN SORS OPERATION AND CHECKOUT Operation The T7047C, G Remote Sensor cont rol element is a negative temp erature coefficient (N TC) thermistor. As the room temperat ure increases, the resistance of the thermistor decre ases. The T7047H Remot e Sensor c ontrol eleme nt is a positive temp erature coefficient (PTC[...]
-
Page 8
62-0179 B .B. 9-01 www .hon eywell.com/ building/c omponents Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. Home and Building Cont rol Home and Buil ding Contr ol Honeywell Honeywell Limit ed-Honeywe ll Limitée 1985 Dougl as Drive Nort h 35 Dynamic Dri ve Golden Val ley, MN 55422 Scarborough, Ontario M1V 4Z[...]