Honeywell HEAT PUMP THERMOSTAT T8411R manual

1
2
3
4
5
6

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell HEAT PUMP THERMOSTAT T8411R, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell HEAT PUMP THERMOSTAT T8411R one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell HEAT PUMP THERMOSTAT T8411R. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell HEAT PUMP THERMOSTAT T8411R should contain:
- informations concerning technical data of Honeywell HEAT PUMP THERMOSTAT T8411R
- name of the manufacturer and a year of construction of the Honeywell HEAT PUMP THERMOSTAT T8411R item
- rules of operation, control and maintenance of the Honeywell HEAT PUMP THERMOSTAT T8411R item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell HEAT PUMP THERMOSTAT T8411R alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell HEAT PUMP THERMOSTAT T8411R, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell HEAT PUMP THERMOSTAT T8411R.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell HEAT PUMP THERMOSTAT T8411R item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ® U.S. Re gistered T radem ark Copyright © 2002 Honeywell • •All Rights Reser ved INSTALLATION I NSTRUCTIONS 69- 1481- 1 T8411R Electronic Heat Pump Thermostat The T841 1R Heat Pump Ther mostat provides 24V control of two-stag e heating and one-st age cooling heat pump system with manual change over fr om heat t o cool. First stage heatin g a[...]

  • Page 2

    T841 1R EL ECT RONIC HEA T PUM P THE RMOST AT 69-1481-1 2 Fig. 1. T ypical location of thermostat . Fig. 2. Moun ting wallp late to wall. Wirin g IMPO RTAN T Use an 1 8-gauge m aximum w ire for wiring the T841 1R Thermostat. All wiring must com ply with local electr ical codes and ordinances . CAUTION Elect rical Shock or Equ ipment Damage Hazard. [...]

  • Page 3

    T841 1R ELECTR ONIC HE AT PUM P THERM OSTA T 3 69-14 81-1 Fig. 4. Restrict wirin g to sh aded a rea. Refer to F ig. 5 for typic al wiring ho okups. A lett er code is located nea r each terminal for id entification. 1. Loosen the termi nal screws on the wallpl ate and connect the system wi res. See Fig. 5. 2. Securely tighte n each terminal screw. 3[...]

  • Page 4

    T841 1R EL ECT RONIC HEA T PUM P THE RMOST AT 69-1481-1 4 Fig. 6. Mounting thermosta t wallp late. OPERATION Setting FAN and S YSTEM Switche s Fan and s ystem set tings are control led manuall y by using the switches located at the bottom of the thermostat case. See Fig. 7. FAN Switch Fan swi tch settings a re: On: The fan run s continuo usly . Use[...]

  • Page 5

    T841 1R ELECTR ONIC HE AT PUM P THERM OSTA T 5 69-14 81-1 Set Temperatu re Setpoint NOTE: T emperatur e setpoi nt range is 4 0° to 9 9°F ( 4° to 39°C). The temperat ure setpoint and the room tempera ture are shown separatel y on the digital display . The ▼ indica tor points to Set when the tem perature setp oint is displayed and to Room when [...]

  • Page 6

    69-1481-1 G.H. Rev . 2-02 Printed in U .S.A. www .hone ywell.com/yo urhome T841 1R EL ECT RONIC HEA T PUM P THE RMOST AT Automation an d Control Solutions Honeywell Honeywell Limited-Honeyw ell Limitée 1985 Douglas D rive North 35 Dynamic Drive Golden Valley, M N 55422 Scarborough, Onta rio M1V 4Z9 5. Press the ▼ key to change the °C or °F ind[...]