Go to page of
Similar user manuals
-
Barcode readers
Honeywell MS5145 Eclipse
52 pages -
Barcode readers
Honeywell Voyager 1200g
12 pages -
Barcode readers
Honeywell Solaris 7820
64 pages -
Barcode readers
Honeywell Vuquest 3310g
208 pages -
Barcode readers
Honeywell 3800gPDF RS-232 Kit Negro
156 pages -
Barcode readers
Honeywell IS3480 QuantumE
210 pages 2.06 mb -
Barcode readers
Honeywell MK2430 Stratos
92 pages -
Barcode readers
Honeywell MS9540 Voyager
56 pages
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell Horizon 7625, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell Horizon 7625 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Honeywell Horizon 7625. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Honeywell Horizon 7625 should contain:
- informations concerning technical data of Honeywell Horizon 7625
- name of the manufacturer and a year of construction of the Honeywell Horizon 7625 item
- rules of operation, control and maintenance of the Honeywell Horizon 7625 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell Horizon 7625 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell Horizon 7625, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell Horizon 7625.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell Horizon 7625 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
METROLOGIC INSTRUMENTS, INC. MS7600 Horizon ® Series Inst allation and User ’ s Guide mlpn_2870_cover_7-03.qxd 7/23/2003 2:32 PM Page 1[...]
-
Page 2
[...]
-
Page 3
ii L OCATI ONS C ORPORATE H EADQUARTERS N ORTH A MERIC A E UROPEAN , M IDDLE E AST & A FRICAN H EADQUARTERS USA, N EW J ERSEY G ERMANY , M UNICH Metrol ogic Instrum ents, Inc. Metrol ogic Instrum ents GmbH Tel: 1- 800-ID -METR O Fa x: 856 -228-66 73 Tel: 49 -89-890 19-0 Fa x: 49-8 9-89 019-200 Email: i nfo@metr ologic.com Email: i nfo@euro pe.m[...]
-
Page 4
iii T ABLE OF C ONTENTS Introducti on........................................................................................................... 1 Scanner and A ccessori es ..................................................................................... 2 Before Installing Your MS 7600 ..........................................................[...]
-
Page 5
1 I NTRODUCTI ON The M S7600 H orizon ® series is M etrologic’s nex t genera tion in-co unter laser bar code scann er. This compa ct, hands-fr ee sca nner is design ed with a dense 20-line omni directi onal s can pattern t hat help s pr ovide fast, effici ent throu ghput with a high first pa ss read rate . The MS 7600 is equipp ed w ith a multit[...]
-
Page 6
2 S CANNER AND A CCESSORIES B AS I C K IT Part # Description MS7600 Horizon Series S canner 00-02407 MetroSelect ® Progr ammi ng Guide 00-02870 MS7600 Horiz on Serie s Insta llation and User ’s Guide 52-52511A 24” EAS cable Guides also availabl e for download at www.metrologic.com. O PT IONAL A CCESSOR IES Part # Description 46-46640 Point of [...]
-
Page 7
3 S CANNER AND A CCESSORIES (C ONTINUE D ) O PT IONAL A CCESSOR IES Part # Description AC to DC Pow er Transform er - Regulat ed 5.2V@ 1A output 46-46759 120V United St ates 46-46616 220V – 240V C ontinent al Europe an 46-46615 220V – 240V U nited Kin gdom 46-46984 220V – 240V C hina 46-46985 220V – 240V A ustrali a 46-46641 Stainless Ste e[...]
-
Page 8
4 B EFORE I NSTALLING Y OUR MS7600 When mounting the MS7600 or replac ing the Top Plate: D O N OT Press on the window. Figure 2 Lift the Top plate straight up to remove. There is no hardware required to remove or replace the top cover. See caution on page 3. There are two installation tabs under the top cover that can be used to place the unit into[...]
-
Page 9
5 M OUNTIN G THE MS7600 S ERIES There are thr ee options for mounting your M S7600. Option “A” uses a she lf to support the un it. Option B lets t he unit hang free in the counter t op. Option C lets the unit hang free in the counter top w ith the use of a stainle ss steel trim ring for support . The tr im ring ( MLP N 46-46641) is an optiona l[...]
-
Page 10
6 M OUNTIN G THE MS7600 S ERIES O PTION B: Free Hanging Suppor t Figure 8: Package Flow (right) Figure 9: Specifications for free hanging support. Figure 10: Installation Tabs[...]
-
Page 11
7 M OUNTIN G THE MS7600 S ERIES O PTION C: T rim Ring ( MLP N 46- 46641, Ad ditiona l Purchase) Figure 11: Counter Top Opening for Trim Ring ( MLPN 46-46641) Figure 12: Trim Ring ( MLPN 46-46641) Installation[...]
-
Page 12
8 Figure 14: Keyboard Wedge Interfa ces I NSTALLATION FO R K EYBOARD W EDGE I NTERFACE 1. Turn off the ho st system. 2. Disconne ct the keyboard fro m the host. 3. Connect th e PowerLink cable to the 2 nd jack fro m the top of the M S7600. 4. Connect the “Y ” end of the PowerLink c able to the keyboar d and the key board port on the ho st. If n[...]
-
Page 13
9 Figure 15: Stand-Alone Keyboard Int erface I NSTALLATION F OR S TAND -A LONE K EY BOARD I NTERFACE 1. Turn off the ho st system. 2. Disconne ct the keyboard fro m the host. 3. Connect th e PowerLink cable to the 2 nd jack from th e top of t he MS7600. 4. Connect th e other end of the PowerLink cable to the keyboard port on the host. Before contin[...]
-
Page 14
10 Figure 17: US B, Inter face I NSTALLATION F OR USB I NTERFACE 1. Turn off the ho st system. 2. Determine if your appl ication requires USB Key board communic ation prot ocols or USB Point of Sale com munica tion protocols. 3. If you require USB Ke yboard communic ation prot ocols, ski p to step 4. If you require USB Po int of Sale communic ation[...]
-
Page 15
11 I NSTALLATION F OR USB I NTERFACE Manufacturer s Note: Plugging the scanner into the USB port of the PC does not guara ntee that scanned inf ormation will ap pear at the PC. A software driver and correct configura tion se tting may also b e requ ired for pr oper co mmunicat ion to occur. 6. Scan the Enabl e USB Defaults bar code to conf igure th[...]
-
Page 16
12 Figure 18: RS232 or Light Pen Interfa ce I NSTALLATION F OR RS232 OR L IGHT P EN I NTERFACES 1. Turn off the ho st system. 2. Connect th e PowerLink cable into the 1 st jack down from the top of the MS7600. 3. Connect th e other end of the PowerLink c able to the host. Before continu ing verify that the PowerLink c able is c onnecte d to the app[...]
-
Page 17
13 I NSTALLATION F OR RS232 OR L IGHT P EN I NTERFACES Step 7, page 12 continued. For RS232 C ommunicat ion: Scan 1 st ³9 9 9 9 9 8 Recall Defaul ts Scan 2 nd ³4 1 5 5 5 4 Enable RS-232 For Light Pen C ommu nication: Scan 1 st ³9 9 9 9 9 8 Recall Defaul ts Scan 2 nd ³4 1 5 5 2 4 Enable Light Pen/W and[...]
-
Page 18
14 Figure 19: RS232/IBM, Interface I NSTALLATION F OR IBM 46 XX I NTE RF ACE 1. Turn off the ho st system. 2. Connect th e MV C cable to the 1 st jack dow n from the top of the MS7600. 3. Connect th e other end of the MVC cable t o the ho st. Before continu ing verify that the MVC cable is connec ted to the appropriat e interface jack on the scanne[...]
-
Page 19
15 Figure 13: OCIA, Interf ace I NSTALLATION F OR OCIA I NTERFACE 1. Turn off the ho st system. 2. Connect th e MV C cable to the 2 nd jack dow n from the top of the MS7600. 3. Connect th e other end of the MVC cable to the host. Before continu ing verify that the MVC cable is connec ted to the appropriat e interface jack on the scanner. An i ncorr[...]
-
Page 20
16 I NSTALLATION OF A S ECONDARY S CANNER 1. Turn off the ho st system. 2. Connect th e round end of th e PowerLink RS23 2 AUX cable [ MLP N 54-54667A] to the RS232 jack o f the secondary scanner ( see f igure 20 ). 3. Connect th e other end of the PowerLink RS232 AU X cab le into t he 3 rd jack down from th e top of the MS 7600 . The follow ing Me[...]
-
Page 21
17 I NSTALLATION OF A S ECONDARY S CANNER 11. Scan the follo wing bar code to conf igure the auxi liary port on the MS7600 to accept a Metrologic scanner as the secondary sc anner. The following bar codes do not apply when using an MS6720 as a secondary scanner. Contact a Metrolo gic representative for additional information on the MS6720. If the s[...]
-
Page 22
18 I NSTALLATION OF A S ECONDARY S CANNER Figure 20: Connector Orientation (Top) Secondary Scanner Setup (Bottom)[...]
-
Page 23
19 S CANNER P ARTS Figure 21: Scanner Parts n Output Window (Laser Ape rture) o Amber LED (Located Und er W indow ) p Red LED (Locat ed Under W indow) q Speaker r Cable Conne ction Area s Stainless Ste el Top (M S7625 units only) t Package Flow Indicator Arrow H ead u Rubber Conne ctor Plug v EAS Deactivation A ntenna Conne c tor n s q p o r o p t [...]
-
Page 24
20 M AINTENANCE Smudges and dirt can interfere with the pr oper s canning of a bar cod e. Therefore, t he output window will need occasiona l cleaning. For the M S7600 glass window: 1. Spray glass cleaner onto li nt free, n on-abras ive clean ing cloth. 2. Gently w ipe the scanner wind ow. For the M S7600 red w indow: 1. Use mild soa p and water wi[...]
-
Page 25
21 S CANNER L ABELS Each scanner has a label on the bottom of the unit. T he label contains information such as the model number, dat e of manufacture, serial number, and caution information. An additional cauti on label is located under the top plat e. The following are examples of these l abels. Figure 23: Label Locations[...]
-
Page 26
22 A UDIBLE I NDICATORS When the M S7600 scanner is in o peration, it provides audib le feedb ack. T hese sounds ind icate the statu s of the sc anner. Ei ght sett ings are av ailabl e for the tone of the be ep (normal, 6 alternat e tones and no t one) plu s three vol ume settings. T o change the tone or v olume , refer to t he Chang ing the Be epe[...]
-
Page 27
23 V ISUAL I NDICATORS There is a red LED and amber LED on the front of the M S7600. When the s canner i s on, the flash ing or constant il luminat ion of the LEDs indicate s the status of the current scan and the scan ner. Figure 24: LEDs No Red or Amber LED The LEDs w ill not be illuminate d if the scanner i s not receivin g power fro m the host [...]
-
Page 28
24 F AILURE M ODES Figure 25: LEDs Flashing A mber and One Raz zberry Tone This ind icates the scanner has ex perienced a laser su bsystem f ailure. Return the unit for r epair at an authorized servic e center. Flashing R ed and Amber and Tw o R az z b e rr y Tones This ind icates the scanner has ex perienced a motor failure. Return the unit for r [...]
-
Page 29
25 C HANGING THE B EEPER T ONE & V OLUME Changing the Beeper Tone Beeper tone s may be pr ogrammed directly or incrementally using the f ollowing bar code. T he new tone will be h eard foll owed by a short p ause. T wo more n ew tones w ill be hear d signi fying the n ew setting has b een stor ed in m emory. The silent (no be ep) tone is also s[...]
-
Page 30
26 P OW E R S AVE M ODES AND IR D ETECTIO N The MS 7600 has five programmable pow er save modes. Refer to the MetroSelect Pro gramming G uide for add itional informatio n on Pow er Save Modes. 1. Blink Power Save Mode: Blinks the l aser OFF & O N after a progra mmed perio d of non-us e. When the scanner r ecognize s a bar code it w ill ex it th[...]
-
Page 31
27 P OW E R S AVE M ODES AND IR D ETECTIO N Figure 27: IR Activation Area Parallel to Package Flow Specificat ions are subj ect to change w ithout notice.[...]
-
Page 32
28 S CAN V OLUME S PECIFICATIONS (B ASED ON 100% UPC B AR C ODES ) Figure 28: Scan Volume in Pl ane Perpendicular t o Flow Figure 29: Scan Volume in Pl ane Parallel to Fl ow Specificat ions subject to change w ithout notic e.[...]
-
Page 33
29 D EPTH OF F IELD BY M IN IM UM B AR C ODE E LE MENT W IDT H (B ASED ON 100% UPC B AR C ODES ) Figure 30: Depth of Field Perpendic ular to Flow Minimum Ba r Code Eleme nt Width ABCD E mm .13 .19 .26 .33 .48 mils 5.2 7.5 10.4 13 19 Specificat ions subject to change w ithout notic e.[...]
-
Page 34
30 T ROUB LESH OOTING G UIDE The follow ing guid e is for refere nce pur poses only. Co ntact a M etrologic representativ e at 1-80 0-ID-M ETRO or 1-800-43 6-3876 to preserve th e limit ed warranty terms. MS7600 S ERIES T ROUBLESHOOTING G UIDE SYMPTOMS POSSIBLE CAUSE(S) SOLUTION All Interfaces No LEDs, beep or motor spin. No power is b eing supplie[...]
-
Page 35
31 T ROUB LESH OOTING G UIDE (C ONTINUED ) SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Scanning a particular symbology that i s not enabled. UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being rea d has be en select ed. The unit pow ers up, but does not scan and /or beep. The sc[...]
-
Page 36
32 T ROUB LESH OOTING G UIDE (C ONTINUED ) SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The bar co de may have been pri nted incorrect ly. Check if it is a che c k digit/ch aracter/or bord er problem. The scanner is not configure d correctly for this type of bar code. Check if check dig its are set properly. Scanner beeps at some bar codes a nd NOT for othe[...]
-
Page 37
33 T ROUB LESH OOTING G UIDE (C ONTINUED ) SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Everything works ex cept for a couple o f characters. These ch aracter s may not be support ed by that country ’s key look up table. Try operating the scanner in Alt mode. RS-232 Only The unit is transmitting each charac ter. Configurati on is n ot correct. Increase th[...]
-
Page 38
34 T ROUB LESH OOTING G UIDE (C ONTINUED ) SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Characters are being dropped . Intercharacter del ay needs to be a dded to the transmitt ed outpu t. Add some int ercharacter delay to the transm itted out put by using the M etroSelect Programming G uide ( MLP N 00-02407). Aux port operation with any interfac e Trouble [...]
-
Page 39
35 D ESIGN S PECIFICATIONS MS7600 S ERIES D ESIGN S PEC IFICA TION S O PERA TIO NA L Light Sour ce: VLD 650 ± 10 nm Laser Pow er: 1.1 m W m aximum Depth of Fie ld: 0 mm to 203. 2 mm (0”- 8.0”) for 0.33 mm (13 mil) bar code Width of S can Field: 87.4 mm (3.4”) @ 0 mm (0.0”); 136 mm ( 5.35”) @ 203. 2 mm (8.0”) Measurem ents in pl ane per[...]
-
Page 40
36 D ESIGN S PECIFICATIONS (C ONTI NUED ) MS7600 S ERIES D ESIGN S PEC IFICA TIONS E LECTRIC A L Input Volta ge: 5.2VDC ± 0.25V Power: 2.6 W Operating Curren t: 500 mA Laser Off Pow er Save Mode = < 350 mA Standby Current: Laser/M otor Off Power Save M ode = <165 mA DC Transformer s: Class II; 5.2 V @ 1A Laser Clas s: IEC 60825-1:1 993+A1:19[...]
-
Page 41
37 RS232 D EM ONSTRAT ION P ROGRAM If an RS232 scanner is not communic ating w ith your IBM compatib le PC, key in the follow ing BASIC program to test th at the c ommunication port and scanner are w orking. This progr am is for demo nstratio n purpo ses only. It is only intende d to prove that cab ling is correct , the com p ort is working, an d t[...]
-
Page 42
38 A PPLICATIONS AND P ROTOCOLS The mode l number on eac h scanner includ es the scanner number and fact ory default com munica tions p rotocol . S CANNER V ERSION I DENTIFIE R C OMMUNICA TION P ROTOCOL ( S ) 7620 7625 13 RS232, IBM 46xx , OCIA, Aux 7620 7625 37 RS232, Light P en, Keyboard W edge , Stand-Alone Key board, USB, Aux The MS 7600 with B[...]
-
Page 43
39 D EFAULT S ETTINGS Many functions of t he sca nner ca n be "pro gramme d" - that is, enabled or disabled. T he scanner is shi pped fro m the factory progra mmed to a set of default cond itions. The def ault parameter of the scann er has a n asterisk ( * ) in the charts o n the follow ing pages. If an a sterisk i s not in the default co[...]
-
Page 44
40 D EFAULT S ETTINGS (C ON TINU ED ) P ARA METER D EF AUL T OCIA RS-232 L IGHT P EN IBM 46XX KBW USB Bars High as Scanned 9 Spaces High as Scanned 9 DTS/SIEM ENS 9 DTS/NIXDORF * 9 NCR F 9 NCR S 9 Poll Light Pen Source 9 Beeper Tone Norm al 9999 9 9 Beep/Transm it Sequence Befor e Transm i t 9999 9 9 Beeper Volum e Loudest 9999 9 9 Communication T [...]
-
Page 45
41 D EFAULT S ETTINGS (C ON TINU ED ) P ARA METER D EF AUL T OCIA RS-232 L IGHT P EN IBM 46XX KBW USB Number of Scan B uffers 1 99 999 9 Transmit EAN-8 Check D i git * 99 99 9 Transmit EAN-13 Check D i git * 99 99 9 Transmit UPC-A Che ck Digit * 99 999 9 Transmit UPC-E Che ck Digit 9 999 9 Expand UP C-E 99 999 9 Convert UPC-A to EAN-13 99 99 9 UPC [...]
-
Page 46
42 D EFAULT S ETTINGS (C ON TINU ED ) P ARA METER D EFAUL T OCIA RS-232 L IGHT P EN IBM 46XX KBW USB UPC Suffix 99 9 Transmit AIM ID Characters 99 9 STX Pref ix 99 9 ETX Suff ix 99 9 Carriage Return * 99 9 Line Feed - disa bled by default in KBW * 99 9 Tab Prefix 99 9 Tab Suffix 99 9 "DE" Disable Com mand 99 "FL" Laser Enab le C[...]
-
Page 47
43 D EFAULT S ETTINGS (C ON TINU ED ) P ARA METER D EF AUL T OCIA RS-232 L IGHT P EN IBM 46XX KBW USB Coupon Code 128 99 as code 39 99 9 Programm abl e Code Lengths 7 avail. 999 9 9 9 Programm abl e Prefix Characters 10 avail. 99 9 Suffix Characte rs 99 9 Prefixes for in dividual Code Types 99 9 Edit ing 99 9 99 9 Inter Scan-Code D elay Programm ab[...]
-
Page 48
44 D EFAULT S ETTINGS (C ONTINUED ) Default settings for “ Aux ” interface The secondary scann er and the MS7600 always communic ate via RS232. Data is relayed to the host via various primar y interfaces. P AR AME TE R D EF AULT OCI A RS-232 L IGHT P EN IBM 46XX KBW USB Aux Baud Rate 38400 99 9 999 Aux parity space 99 9 999 Aux data bits 7 99 9[...]
-
Page 49
45 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections The MS 7600 scanner i nterface s terminate to 10-pin modular ja cks located on t he back of the unit. The serial # labe l indicate s the model number of the scanner. Figure 31: Scanner Interface Ports MS762x- 13 OCIA MS762x- 13 IBM 46x x Pin Function Pin Function 1 G round 1 G round 2 [...]
-
Page 50
46 S CANNER AND C ABLE T ERMINATIONS (C ONTINUED ) Figure 32: Scanner Interface Ports MS762x- 37 Keyboar d W edge, Stand-Ke yboard or USB MS762x- 37 RS- 232 o r Light Pe n Pin Function Pin Function 1 Ground 1 Ground 2 USB D- 2 RS-232 Transmit Out put 3 USB D+ 3 RS-232 Receive Input 4 PC Data 4 RTS Output 5 PC Clock 5 CTS Input 6 KB Clock 6 DTR Inpu[...]
-
Page 51
47 S CANNER AND C ABLE T ERMINATIONS (C ONTINUED ) Cable Connector Configurations (Host End) PowerLink Cab le MLPN 54-54 xxx* Pin Function 1 Shield Ground 2 RS-232 Transmit O utput 3 RS-232 Receive In put 4 DTR Input 5 Power/Signal Grou nd 6 Reserved 7 CTS Input 8 RTS Output 9+ 5 V D C xxx* speci fies connecti on to the host USB PowerL ink Cable ( [...]
-
Page 52
48 S CANNER AND C ABLE T ERMINATIONS (C ONTINUED ) Cable Connector Configuration The Po werLink cable is term inated with a 5- pin DIN f em ale connector on one end, an d a 6- pin m ini DIN m ale on t he other. Metrolog ic will s upp ly an ada pter ca ble wit h a 5-pi n DIN male c onnect or on one end and a 6- pin m ini DIN f emale c onnect or on t[...]
-
Page 53
49 L IMITED W ARRANTY The MS7600 Series scanners are manufactured by Met rologic at its Blackwood, New Jersey, U.S. A. facility. The MS7600 Series scanners have a three (3) year l imited warranty from the date of manufacture. Metrologic warrants and represents that all MS7600 Series scanners are free of all defect s in material, workmans hip and de[...]
-
Page 54
50 N OTICES This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interfer ence, and (2) this device must accept any interferen ce received, including interference that may cause undesired operation. This equipment has been tested and foun d to comply with the[...]
-
Page 55
51 N OTICES (C ONTINUED ) Attent ion L'emploi de commandes, réglag es ou procédés autres que ceux décrits ici pe ut entraîner de graves irradiations. Le client ne doit en aucun cas essa yer d'entretenir lui-même le scanner ou le las er. Ne regardez jamais directement le rayon laser, même si vous croyez que le scanner est inactif. N[...]
-
Page 56
52 P ATENTS For patent information, please refer to www.honeywellaidc.com/patents .[...]
-
Page 57
53 I NDEX A Accessorie s .................................. 2 Adapter ....................................... 48 Audible ........................................ 22 Autodiscr iminates ....................... 35 B Bar Code .............................. 28, 29 Beep ..................................... 22, 40 C Cable .......... 2, 12, 19, 33-35, 45-[...]
-
Page 58
54 I NDEX T Termination ................................. 35 Transformers .............................. 36 Troublesh ooting ...30, 31, 32 , 33, 34 U USB ............................................ 10 V Ventilation ................................... 36 Visual .......................................... 23 Voltage ..................................[...]
-
Page 59
[...]
-
Page 60
December 2 003 Printed in the U SA 00 - 02870 D[...]