Go to page of
Similar user manuals
-
Smoke Alarm
Honeywell C7023J
12 pages 0.57 mb -
Smoke Alarm
Honeywell H7635C
8 pages 0.21 mb -
Smoke Alarm
Honeywell C7021R
12 pages 0.57 mb -
Smoke Alarm
Honeywell C7023K
12 pages 0.57 mb -
Smoke Alarm
Honeywell C7041R
12 pages 0.57 mb -
Smoke Alarm
Honeywell MS-2
56 pages 1.8 mb -
Smoke Alarm
Honeywell C7031F
12 pages 0.57 mb -
Smoke Alarm
Honeywell C7023N
12 pages 0.57 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell IPGSM-DPC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell IPGSM-DPC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Honeywell IPGSM-DPC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Honeywell IPGSM-DPC should contain:
- informations concerning technical data of Honeywell IPGSM-DPC
- name of the manufacturer and a year of construction of the Honeywell IPGSM-DPC item
- rules of operation, control and maintenance of the Honeywell IPGSM-DPC item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell IPGSM-DPC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell IPGSM-DPC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell IPGSM-DPC.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell IPGSM-DPC item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
I I P P G G S S M M - - D D P P C C C C o o m m m m e e r r c c i i a a l l F F i i r r e e C C o o m m m m u u n n i i c c a a t t o o r r I I n n s s t t a a l l l l a a t t i i o o n n a a n n d d S S e e t t u u p p G G u u i i d d e e IPGSM-DPC Commercial Fire Comm unicator RADIO TROUBLE LO W BA TT AC ON AC LOSS 800-09370 6/11 Rev. A[...]
-
Page 2
Contents General Info rmation ............................................................................................................ ...........1 Package Contents ............................................................................................................... ........1 Compatible Fi re Panels ...................................[...]
-
Page 3
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 1 – General Information The IPGSM-DPC Commercial Fire Communicator (henceforth referr ed to as IPGSM-DPC) includes everything you ne ed to upgrade a commercia l fire system that prev iously reported by POT S to a system that uses the Internet as its primary r eporting pa[...]
-
Page 4
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 2 – Operation The IPGSM-DPC replac es the fire panel's POTS co mmunications path. When an ev ent occurs, the fire pane l goes off-hook to dia l the central station. Th e IPGSM-DPC detects the o ff-hook condition and pro vides the fire panel with a dial tone. When th[...]
-
Page 5
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 3 – Installation ULC Compliance To meet Canadian ULC compl ian ce, ensure the following: IPGSM-DPC must be installed in accordance with Canadian Electrical Code, Part 1. IPGSM-DPC must be mounted in the same room and wi thin 20 feet of the fire panel. The wiring [...]
-
Page 6
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 4 – STEP 3 – Determine the Signal Strength and Select a Location IMPORTANT - Do Not mount this de vice outdoors. RF Exposure Warning – The antenna(s ) used for this transmitter must be installed to provide a separati on distance of at least 20 cm from all persons and[...]
-
Page 7
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 5 – 4. Connect the L ED Display board to its conn ector, then slide the board into the mountin g rails. (Refer to the “ LED Display Information ” topic if a wire is detached from its connector.) 5. Carefully re move the packaging mat eri al that surrounds the PowerBo[...]
-
Page 8
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 6 – IPGSM-DPC-001-V1 TB 1 6 7 8 5 10 11 9 2 3 4 1 FOR EXTERNAL ANTENNA 50 OHM MMCX ONLY PRIMARY POWER: 9 - 16.5 VAC CURRENT: 900mA PEAK, 70mA STANDBY BATTERY: 8V. 3.1 AHr FOR 24 Hr BACKUP FCC:XXXXXXXXXX IC: YYYYYYYYYY RSSI M0 M1 GPRS IBS 7720P PROGRAMMER PORT NOT FOR TEL[...]
-
Page 9
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 7 – Wiring the 659EN Line Faul t Monitor (if require d) The IPGSM-DPC is compatible with the Honeywell brand F ACP’s listed on page 1 wh en the model 659EN Line Fault Monitor is installed. 1. Refer to the installation guide for the 659EN. 2. Mount the 659EN on the lowe[...]
-
Page 10
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 8 – STEP 5 – Program the Communications Module You must use the 7720P Programming tool to program the IPGSM-DPC. When using the 7720P Pr ogramming tool, the valu es given below are for mo st installations. Press the [#] key to accept the disp layed default value ( xxx)[...]
-
Page 11
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 9 – To exit the progr amming mode, press [ N] in response to the "Review?" pr ompt. Then press [Y] to the "Exit Prog Mode?" prompt. Upon exiting, the ro ot file is updated to log the changes made. A message is dis played telling the user that this ste[...]
-
Page 12
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 10 – Dialer Capture Mo dule Information LED Indicator STATUS RED – Steady ON Messages exist in buffer. RED – Flashing No messages to be sent. Waiting for messages. GREEN – Steady ON Normal Indication. GREEN – Blinks every 2 sec. PowerBoost1 communication problem.[...]
-
Page 13
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 11 – PowerBoost1 Module Information LED Indicator STATUS AC (green) AC power available. ACTIVE (green) Cyclical flashing – normal communications. Repetition of 3 flashes – loss of communications. LOW BATT (yellow) Missing or low battery. TROUBLE (yellow) One or more [...]
-
Page 14
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 12 – iGSM Communications Module Information TB 1 6 7 8 5 10 11 9 2 3 4 1 PRIMARY POWER: 9 - 16.5 V AC CURRE N T: 900mA PEAK, 70mA STA N DBY BATTERY: 8V . 3.1 AHr FOR 24 Hr BACKUP FCC:XXXXXXXXXX IC: YYYYYYYYYY RSSI M0 M1 GPRS IBS iPGSM-DPC-012- V 0 RSSI / Mode and status [...]
-
Page 15
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 13 – RF Specifications Band Transmission Frequency (MHz) Transmit Power (dBm) Receive Frequency (MHz) Receive Sensitivity (dBm) Number of Channels Channel Spacing (MHz) Duplex Separation (kHz) GSM 850 824-849 33 869-894 -107 124 200 45 GSM 900 890-915 33 935-960 -107 124[...]
-
Page 16
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 14 – IPGSM-DPC Trouble Detection Information Telco 1 is used for th e Fire Panel to output con tact ID messages to the IPGS M-DPC, and Telco 2 is us ed by the IPGSM-DPC to repor t faults to the Fire Panel. If Telco 1 is not operational, the Fir e Panel will use Telco 2 t[...]
-
Page 17
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 15 – NOTES[...]
-
Page 18
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 16 – NOTES[...]
-
Page 19
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 17 – NOTES[...]
-
Page 20
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 18 – NOTES[...]
-
Page 21
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 19 – NOTES[...]
-
Page 22
IPGSM-DPC Commercial Fire Communicato r – Installation and Setup Guide – 20 – NOTES[...]
-
Page 23
Wiring Diagram The wiring diagram below is dep icted for point-to-point electrical con nection checks used for tr oubleshooting or componen t replacement. It is not in tended to show the phys ical routing of wires. When replacing a wire or componen t, ensure the wire is route d in the same manner as the orig inal factory wire. IPGSM-DPC-007-V1 TB 1[...]
-
Page 24
IC STATEMENT Notice: This Class A digital apparatus com plies with Canadian ICES-003. Cet appareil numérique d e la classe A est conforme à la norme NMB-003 du Canada. IC STATEMENT This device complies with RSS 210 of IC. Operation is subject to the following two conditio ns: (1) This device may not cause harmful interference. (2) Thi s device mu[...]