Honeywell Q327A manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell Q327A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell Q327A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell Q327A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell Q327A should contain:
- informations concerning technical data of Honeywell Q327A
- name of the manufacturer and a year of construction of the Honeywell Q327A item
- rules of operation, control and maintenance of the Honeywell Q327A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell Q327A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell Q327A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell Q327A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell Q327A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Q314 and Q327A Pilot Bur ners J. H. • Rev. 12-92 • © Honeywell Inc. 1992 • Form Number 69-0519—3 TRADELINE A pplication Pilot burners provide main burner ignition for standing pilot natural and LP gas systems. Used with a thermocouple to provide automatic pilot safety control. Used with a thermopile in a self-powered system. See Table 1 fo[...]

  • Page 2

    2 CONNECT PILOT GAS TUBING 1. Cut tubing to desired length and bend as necessary for routing to pilot burner. Do not make sharp bends or deform tubing. Do not bend tubing at control after compression nut has been tightened, as this can result in gas leakage at connection. 2. Square off and remove burrs from end of tubing. 3. Push tubing into compre[...]

  • Page 3

    INSERT ORIFICE M27083 SPUD ORIFICE INSERT ORIFICE CROSS SECTION 3 69-0519—3 Fig. 7—Changing spud and insert orifices. Fig. 6—Bleed gas tube installation. THIS DIMENSION SHOULD BE MAXIMUM OF 3/8 INCH [9.5 mm] WHEN BLEED TUBE IS IN FINAL POSITION. BLEED TUBE CLIP M3284 1/8 IN. STEEL TUBING CHANGE INSERT ORIFICES (See Fig. 7) 1. Disconnect pilot[...]

  • Page 4

    Service W ARNING FIRE OR EXPLOSION HAZARD CAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH Perform Gas Leak Test anytime work is done to the system. PILOT OUTAGE 1. If pilot flame goes out during normal operation, but is properly adjusted, recheck Mounting and Location instruc- tions on page 1. 2. If all mounting and location instructions are fol[...]

  • Page 5

    PILOT TURNDOWN TEST (30 mV safety control systems) The Pilot Turndown Test assures that the pilot flame ignites the main burner within four seconds from the time gas reaches the main burner. In this test, the pilot flame is just sufficient enough to hold in the power unit or just above the point of flame extinction (whichever occurs at a higher pil[...]

  • Page 6

    6[...]

  • Page 7

    76 9 - 0519—3[...]

  • Page 8

    Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited—Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley, MN 55422 Scarborough, Ontario M1P 2V9 Printed in U.S.A. QUALITY IS KEY[...]