Honeywell R7426A manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell R7426A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell R7426A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell R7426A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell R7426A should contain:
- informations concerning technical data of Honeywell R7426A
- name of the manufacturer and a year of construction of the Honeywell R7426A item
- rules of operation, control and maintenance of the Honeywell R7426A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell R7426A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell R7426A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell R7426A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell R7426A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    HONEYWELL Copyright © 2007 Honeyw ell GmbH  All Rights Reserved EN1B-0203GE51 R0507C R7426A,B,C TEMPERA TURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK INST ALLA TION & ST ART -UP INSTRUCTIONS Fig. 1. T emperature Controller Contents General ................................................................................ 1 Before Insta lla[...]

  • Page 2

    R7426A,B,C TEMPERATURE CONTROLLER WI TH AND WITHOUT REAL-TIME CLOCK EN1B-0203GE51 R0507C 2 WIRING Screwless ty pe, spring loaded terminals are provided on the controllers for panel and field w iring. These terminals are suitable for solid conductors as w ell as tinned or with multicore cable end, stranded wires up to 1.5 mm 2 . T o make a terminati[...]

  • Page 3

    R7426A,B,C TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK 3 EN1B-0203GE51 R0507C CONFIGURATION AND CONTROL PARAMETERS The controllers R7426A,B,C include two groups of settings *) (I and II) for control and confi guration parameters that are automatically selected during programming. For parameter Ctrltyp = Lo, setting I is selected, and fo[...]

  • Page 4

    R7426A,B,C TEMPERATURE CONTROLLER WI TH AND WITHOUT REAL-TIME CLOCK EN1B-0203GE51 R0507C 4 config. par. R7426 no. name description default setting I / II A B C actual val ue C.12 T2ext Enable / Disables the T1 sensor input to be used for both T1 and T2 inputs. 0 x x x 0 1 T2 installed T1 signal used for T2 C.13 LimTyp Limitation type determines w h[...]

  • Page 5

    R7426A,B,C TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK 5 EN1B-0203GE51 R0507C control par. setting I / setting II R7426 no. name description low high def. reso- lution unit A B C actual val ue P.01 W1 Main setpoint for input T1 0 50 / 130 21 / 70 0.5 ° C x x x P.02 Wlim Limit setpoint (low or high) for input T2 5 / 30 50 / 130 16 / 90 [...]

  • Page 6

    R7426A,B,C TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK EN1B-0203GE51 R0507C 6 CONFIGURATION SETTINGS The controllers R7426A,B are supplied with unconfigured outputs to avoid damage of installed final control devices by supply of not applicable output signals if the controller pow er supply is turned on. All configuration parameters must[...]

  • Page 7

    R7426A,B,C TEMPERATURE CONTROLLER WITH AND WITHOUT REAL TIME CLOCK 7 EN1B-0203GE51 R0507C Output Signal Mode YMode (C.11) Sequence Operation The controllers R7426B,C are supplied from the factory configured for sequence operation of heating, mixed air , and cooling control. The sequence operation can be c onfigured for the following control applica[...]

  • Page 8

    R7426A,B,C TEMPERATURE CONTROLLER WI TH AND WITHOUT REAL TIME CLOCK EN1B-0203GE51 R0507C 8 Summer / Winter Time Change AddHour / SubHour (C.16 / C.17) These configuration parameters are only available on controllers with R TC. The configuration parameter A ddHour or SubHour are required to adjust the month for summer/winter time change or vice vers[...]

  • Page 9

    R7426A,B,C TEMPERATURE CONTROLLER WITH AND WITHOUT REAL TIME CLOCK 9 EN1B-0203GE51 R0507C limit or cascade sensor (T2) to operate the output device from full open (100%) to full closed (0%) or vice versa. Xp1 is the throttling range fo r the main control loop, Xp2 is used if limitation or cascade c ontrol (submaster control loop) is active (see T a[...]

  • Page 10

    R7426A,B,C TEMPERATURE CONTROLLER WI TH AND WITHOUT REAL TIME CLOCK EN1B-0203GE51 R0507C 10 Setting Guidelines for Reset Time of P+I Control The reset time tr should be adjusted to 2...3 times of the response time T u , which is the time interval betw een the beginning of a sustained disturbance (e.g. rapid step change of valve position) and the in[...]

  • Page 11

    R7426A,B,C TEMPERATURE CONTROLLER WITH AND WITHOUT REAL TIME CLOCK 11 EN1B-0203GE51 R0507C Y (% ) 100 T ( ) ° C SOFFS SOFFS CTRPH CTRPC Xph Xpc OCCUPIED UNOCCUPIED Fig. 5. Night cycle NightLow and NightHigh The night cycle program autom atically cycles betw een the user selected upper and lower limit s and turns on full heating or cooling with for[...]

  • Page 12

    R7426A,B,C TEMPERATURE CONTROLLER WI TH AND WITHOUT REAL TIME CLOCK EN1B-0203GE51 R0507C 12 Changing Operating Modes Fig. 7 shows the six operati ng modes. After power-up the controller version is displayed and the controller enters the standard display mode. In this mode, selected input or output values and on controllers with r eal-time clock the[...]

  • Page 13

    R7426A,B,C TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK 13 EN1B-0203GE51 R0507C Time Out After approximately 10 min of inactivity (no button has been pressed: time out), each m ode returns automatically to standard display mode. Input s that have not been confirmed by the SET button are ignored by the controller and old parameter values [...]

  • Page 14

    R7426A,B,C TEMPERATURE CONTROLLER WI TH AND WITHOUT REAL-TIME CLOCK EN1B-0203GE51 R0507C 14 Displaying Actual Values In the standard display mode, one of nine actual values, the actual time, or the date can be selected and displayed by pushing the SEL button. The icons of the permanently displayed controller mode are described in the following t ab[...]

  • Page 15

    R7426A,B,C TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK 15 EN1B-0203GE51 R0507C • T o release the manual override (fixed) of the output, select the output, enter output adj ustment mode and push the + and - button simultaneously . Pushing the SEL button leads back to standard display mode. R7426B AND R7426C, ONL Y WITHOUT : CONTROL LOO[...]

  • Page 16

    R7426A,B,C TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK EN1B-0203GE51 R0507C 16 Using the Schedules (with RTC, only) T wo schedules, one for programming the schedule points and one for holiday programming, are available. The standard schedule is used to switch the controller mode (off, night, standby or comfort) at programmed schedule po[...]

  • Page 17

    R7426A,B,C TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK 17 EN1B-0203GE51 R0507C Selecting Clock and Sche dules (with RTC, only) DA TE & TIME SELECTION ST ANDARD SCHEDULE SELECTION HOLIDA Y SCHEDULE SELECTION STA NDARD SCHEDULE PROGRAMMING DATE & TIME ADJUSTMENT HOLIDA Y SCHEDULE PROGRAMMING Fig. 13. Clock and schedules selection [...]

  • Page 18

    R7426A,B,C TEMPERATURE CONTROLLER WI TH AND WITHOUT REAL-TIME CLOCK EN1B-0203GE51 R0507C 18 Programming Holiday Schedule (with RTC, only) The holiday schedule programming is used to program each day of the year (01.01 ... 31.12.) as a holiday (day type = H1, H2 or H3) or as a normal day (day ty pe = H0 is default). Pushing the + or - button during [...]

  • Page 19

    R7426A,B,C TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK 19 EN1B-0203GE51 R0507C NOTES (WITH RTC, ONLY) day Jan. Feb. March Ap r i l ) May June July A ugust Sept. Oct. Nov . Dec. 1 . 2 . 3 . 4 . 5 . 6. 7. 8. 9. 10. 11 . 1 2 . 1 3 . 1 4 . 1 5 . 1 6 . 1 7 . 1 8 . 1 9 . 2 0 . 2 1 . 2 2 . 2 3 . 2 4 . 2 5 . 2 6 . 2 7 . 2 8 . 29. 1) 30. 31. 1) [...]

  • Page 20

    R7426A,B,C TEMPERATURE CONTROLLER WI TH AND WITHOUT REAL-TIME CLOCK Manufactured for and on behalf of the Environment al and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Böblinger Straße 17 D-71101 Schönaich [...]