Honeywell SERIES 2000 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell SERIES 2000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell SERIES 2000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell SERIES 2000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell SERIES 2000 should contain:
- informations concerning technical data of Honeywell SERIES 2000
- name of the manufacturer and a year of construction of the Honeywell SERIES 2000 item
- rules of operation, control and maintenance of the Honeywell SERIES 2000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell SERIES 2000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell SERIES 2000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell SERIES 2000.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell SERIES 2000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 63-4356—1 Series 2000 Commercial Microelectronic Thermostat ® U.S. Registered T rademark Copyright © 1996 Honeywell Inc. • All Rights Reserved Contents Features .................................................................. 3 Programming ........................................................... 4 T roubleshooting .....................[...]

  • Page 2

    63-4356—1 2 Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day System Fan Copy Occupied Start Time Run Program Temporary Occupied Continuous Unoccupied Set Current Day/Time Clear Start Time Unoccupied Temp Heat/Cool Settings Auto System Fan Mon Room AM Occupied Heat M10256 SET OVERRIDE TEMPERATURE OFFSET AND ACTI[...]

  • Page 3

    3 63-4356—1 FEA TURES •P r ogram up to tw o Occupied and two Unoccupied time periods f or each daily schedule. • Set different schedules f or each day of the week. •T emporary temperature overrides. •P r ogram cop y key .[...]

  • Page 4

    63-4356—1 4 PROGRAMMING The keyboard is located behind the thermostat cover . Sixteen keys are used to set, review and modify programmed times and temperature settings. The thermostat display shows day , time, program period and temperature. The thermostat can be set for two Occupied and two Unoccupied times for each day of the week (28 independe[...]

  • Page 5

    5 63-4356—1 Day Occupied Period 1 Unoccupied Period 1 Occupied Period 2 Unoccupied Period 2 Monday Tuesday Wednesday Thursday Friday Saturday Sunday[...]

  • Page 6

    63-4356—1 6 The program has four temperature settings, Occupied and Unoccupied heat and cool. The thermostat will operate at the Unoccupied temperature setting unless the thermostat is programmed. The following chart shows the default temperature settings. Occupied Setpoint Unoccupied Setpoint Control Default Desired Default Desired Heating 70 °[...]

  • Page 7

    7 63-4356—1  Press Day until the current day is displayed. NOTE: Sun = Sunday , Mon = Monday , T ue = T uesday , Wed = Wednesday , Thu = Thursday , Fri = Friday , Sat = Saturday . M4952B Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day System Fan Copy Occupied Start Time Run Program Temporary Occupied Contin[...]

  • Page 8

    63-4356—1 8  Press Day until the desired day is displayed. AM Wed Occupied 1 Set Program Start Time M4956A Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day System Fan Copy Occupied Start Time Run Program Temporary Occupied Continous Unoccupied Set Current Day/Time Clear Start Time Unoccupied Temp Heat/Cool S[...]

  • Page 9

    9 63-4356—1  Press increase ▲ or decrease ▼ key until the desired start time is displayed. Un PM Wed Occupied 1 Set Program Start Time M4961A Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day System Fan Copy Occupied Start Time Run Program Temporary Occupied Continous Unoccupied Set Current Day/Time Clear[...]

  • Page 10

    63-4356—1 10  Press Day to select the day to be copied if different from the day displayed. M4966A Set Program Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day System Fan Copy Occupied Start Time Run Program Temporary Occupied Continous Unoccupied Set Current Day/Time Clear Start Time Unoccupied Temp Heat/Co[...]

  • Page 11

    11 63-4356—1  Repeat steps  through  for all the days desired.  Press Run Program. M4954A Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day System Fan Copy Occupied Start Time Run Program Temporary Occupied Continous Unoccupied Set Current Day/Time Clear Start Time Unoccupied Temp Heat/Cool Settings [...]

  • Page 12

    63-4356—1 12  Press Heat/Cool Settings to change between heat and cool settings. Cool Occupied Setting M4972A Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day System Fan Copy Occupied Start Time Run Program Temporary Occupied Continous Unoccupied Set Current Day/Time Clear Start Time Unoccupied Temp Heat/Coo[...]

  • Page 13

    13 63-4356—1  Press Heat/Cool Settings to change between heat and cool settings. Un Cool Setting Occupied M4976B Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day System Fan Copy Occupied Start Time Run Program Temporary Occupied Continous Unoccupied Set Current Day/Time Clear Start Time Unoccupied Temp Heat/[...]

  • Page 14

    63-4356—1 14  Press Clear Start T ime. Occupied 1 Set Program Start Time M4979B Mon Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day System Fan Copy Occupied Start Time Run Program Temporary Occupied Continous Unoccupied Set Current Day/Time Clear Start Time Unoccupied Temp Heat/Cool Settings Clear Start Tim[...]

  • Page 15

    15 63-4356—1  Press increase ▲ or decrease ▼ key until the desired temperature offset is displayed (range is 0 ° to 5 ° F). M4981A Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day System Fan Copy Occupied Start Time Run Program Temporary Occupied Continous Unoccupied Set Current Day/Time Clear Start Ti[...]

  • Page 16

    63-4356—1 16 NOTE: If the of fset is zero, the default setting changes in one degree incre- ments. If the offset is 1 through 5, the default setting changes by plus or minus the offset. Auto System Fan Auto AM Wed Override Temporary Room M4983B Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day System Fan Copy Oc[...]

  • Page 17

    17 63-4356—1  Press Heat/Cool Setpoint to change between heat and cool settings. Use increase ▲ or decrease ▼ key to adjust temperature settings.  Press Run Program again to cancel the Hold and to return to the program. M4954A Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day System Fan Copy Occupied S[...]

  • Page 18

    63-4356—1 18 TROUBLESHOOTING GUIDE Symptom Action Display will not come on. • Check if the circuit breaker is tripped—reset the circuit breaker. • Check if the fuse is blown—replace the fuse. • Check if the system switch at the equipment is in the Off position— set to the On position. • Check wiring between thermostat and HVAC equip[...]

  • Page 19

    19 63-4356—1 TROUBLESHOOTING GUIDE (Continued) Symptom Action Cooling will not come on. • Check if the circuit breaker is tripped—reset the circuit breaker. • Check if the fuse is blown—replace the fuse. • Check if the system switch at the equipment is in the Off position— set to On position. • If 24 Vac is present, proceed with tro[...]

  • Page 20

    63-4356—1 20 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422-4386 63-4356—1 J.H. Rev. 12-96 20 www .honeywell.com/buliding/components[...]