Go to page of
Similar user manuals
-
Fan
Honeywell HF910
20 pages 1.53 mb -
Fan
Honeywell HW-628
24 pages 0.29 mb -
Fan
Honeywell HS-120 Series
21 pages 0.46 mb -
Fan
Honeywell HT-800
16 pages 0.19 mb -
Fan
Honeywell TC10PM Series Air Cooler
67 pages 9.97 mb -
Fan
Honeywell HY201
24 pages 1.41 mb -
Fan
Honeywell HFT-3108B
16 pages 1.48 mb -
Fan
Honeywell HT-800C
16 pages 0.19 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell ST9103A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell ST9103A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Honeywell ST9103A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Honeywell ST9103A should contain:
- informations concerning technical data of Honeywell ST9103A
- name of the manufacturer and a year of construction of the Honeywell ST9103A item
- rules of operation, control and maintenance of the Honeywell ST9103A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell ST9103A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell ST9103A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell ST9103A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell ST9103A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Copyright © 1997 Honeywell Inc. • All Rights Reserved INST ALLA TION INSTRUCTIONS X-XX UL 69-0771B ST9103A Electronic Fan T imer APPLICA TION The ST9103A Electronic Fan T imer integrates control of all burner and circulator fan operations in an oil furnace. This control is the central wiring point for most of the electrical components in the fur[...]
-
Page 2
2 S9103A ELECTRONIC F AN TIMER 69-0771B Fig. 1. T ypical ST9103A wiring connections. THERMOSTAT R G Y W R Y C W G LO ML MH HI CIRCULATING FAN STARTING CAP X C 24 VAC 120 VAC M5551 C O O L C O N T E A C B U R N E R UNUSED MOTOR 123 4 5 67 BURNER MOTOR ST9103 L1 L2 ORANGE T1 T2 (BLACK) (WHITE) R8991 OIL PRIMARY CONTROL FLAME DETECTOR CAD CELL 1 INTER[...]
-
Page 3
S9103A ELECTRONIC F AN TIMER 3 69-0771B Fig. 2. ST9103A internal schematic. K2 COOL ST9103A OIL ELECTRONIC FAN TIMER R W Y G C THERMOSTAT C N2 M1 M2 CN6-9 K1 CIRCULATION BLOWER R8991 OIL PRIMARY CONTROL NOTE: DOTTED LINES REPRESENT PRINTED CIRCUIT BOARD WIRING. M5552 ELECTRONIC AIR CLEANER (OPTIONAL) TO 120 VAC POWER SUPPLY R8991 LIMIT SENSOR CIRCU[...]
-
Page 4
4 S9103A ELECTRONIC F AN TIMER 69-0771B Fig. 3. Setting delay off switches. ST9103 Operating Sequence. 60 SEC 90 SEC 120 SEC 150 SEC M5550 DELAY OFF SWITCH SETTINGS ST9103A G W R Y C X C C O O L C O N T E A C B U R N E R UNUSED MOTOR 123 4 5 67 H E A T 3 12 1 2 ON 1 2 ON 1 2 ON 1 2 ON 1 2 ON H U M Action System Response Thermostat calls for heat. ([...]
-
Page 5
S9103A ELECTRONIC F AN TIMER 5 69-0771B ST9103 Operating Sequence (Continued). Action System Response Thermostat ends call for fan. (G terminal is de-energized.) • Circulating fan is de-energized. Limit switch string opens. • Oil primary control shuts off burner. • Circulating fan is energized immediately at heat speed. • ST9103A opens oil [...]
-
Page 6
6 S9103A ELECTRONIC F AN TIMER 69-0771B 69-0771B G.H. 3-97 Printed in U.S.A. Home and Building Control Honeywell Limited-Honeywell Limitée 155 Gordon Baker Road North York, Ontario M2H 2C9 Home and Building Control Honeywell Inc. Honeywell Plaza P.O. Box 524 Minneapolis MN 55408-0524 Helping You Control Your World ¤[...]
-
Page 7
Copyright © 1997 Honeywell Inc. • All Rights Reserved INST ALLA TION INSTRUCTIONS X-XX UL 69-0771B T emporisateur Électronique pour ventilateur ST9103A APPLICA TION Le temporisateur électronique ST9103A pour ventilateur assure la commande complète du brûleur et du ventilateur de la pompe de circulation dans un appareil de chauffage au mazout[...]
-
Page 8
2 TEMPORISA TEUR É LECTRONIQUE POUR VENTILA TEUR ST9103A 69-0771B Fig. 1. Sch é ma de raccordement type du ST9103A. THERMOST A T R G Y W R Y C W G VENTILA TEUR DE CIRCULA TION D ’ AIR CONDENSA TEUR DE D É MARRAGE X C MF5551 C O N T B U R N E R 123 4 5 67 MOTEUR DU BR Û LEUR ST9103 L1 L2 ORANGE T1 T2 (NOIR) (BLANC) R É GULA TEUR PRIMAIRE DE M[...]
-
Page 9
TEMPORISA TEUR É LECTRONIQUE POUR VENTILA TEUR ST9103A 3 69-0771B Fig. 2. Sch é ma interne du ST9103A. K2 REFROIDISSEMENT TEMPORISA TEUR É LECTRONIQUE POUR VENTILA TEUR ST9103A R W Y G C THERMOSTAT C N2 M1 M2 CN6-9 K1 N.B. LES LIGNES POINTILL É ES REPR É SENTENT LE C Â BLAGE DE LA CAR TE DE CIRCUITS IMPRIM É S. MF5552 FIL TRE À AIR É LECTR[...]
-
Page 10
4 TEMPORISA TEUR É LECTRONIQUE POUR VENTILA TEUR ST9103A 69-0771B Fig. 3. R é glage des commutateurs de temporisation d ’ arr ê t. S é quence de fonctionnement du ST9103A. MF5550 R É GLAGE DES COMMUTATEURS DE TEMPORISATION D ’ ARR Ê T ST9103A G W R Y C X C B U R N E R 123 4 5 67 3 12 1 2 ON 1 2 ON 1 2 ON 1 2 ON 1 2 ON H U M 60 SECONDES 90[...]
-
Page 11
TEMPORISA TEUR É LECTRONIQUE POUR VENTILA TEUR ST9103A 5 69-0771B S é quence de fonctionnement du ST9103A (Continu é ). Action R é ponse du syst è me Le thermostat commande le refroidissement. (Bornes G et Y sous tension.) • Le ventilateur de circulation d ’ air est actionn é en r é gime refroidissement. • Le compresseur de refroidisse[...]
-
Page 12
6 TEMPORISA TEUR É LECTRONIQUE POUR VENTILA TEUR ST9103A 69-0771B 69-0771B G.H. 3-97 Imprim é aux É tats-Unis Home and Building Control Honeywell Limited-Honeywell Limitée 155 Gordon Baker Road North York, Ontario M2H 2C9 Home and Building Control Honeywell Inc. Honeywell Plaza P.O. Box 524 Minneapolis MN 55408-0524 Pour la ma trise de votre un[...]