Honeywell T8011R manual

1
2
3
4
5
6

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell T8011R, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell T8011R one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell T8011R. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell T8011R should contain:
- informations concerning technical data of Honeywell T8011R
- name of the manufacturer and a year of construction of the Honeywell T8011R item
- rules of operation, control and maintenance of the Honeywell T8011R item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell T8011R alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell T8011R, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell T8011R.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell T8011R item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    X-XX UL INST ALLA TION INSTRUCTIONS ®U.S. Registered Trademark Copyright © 2002 Honeywell • • All Rights Reserved T8011R Programmable Heat Pump Thermostat APPLICATION The T8011R Heat Pump Thermostat provides 24 Vac control of a two-stage heating and one-stage cooling heat pump system with manual changeover from heat to cool. First stage heati[...]

  • Page 2

    69-1436–1 2 T801 1R PROGRAMMABLE HEA T PUMP THERMOST A T 5 FEET [1.5 METERS] YES NO NO NO M11338 Fig. 1. Typical location of thermostat. Fig. 2. Mounting wallplate to wall. Wiring IMPORTANT Use 18-gauge maximum wire for wiring the T8011R Thermostat. All wiring must comply with local electrical codes and ordinances. Disconnect the power supply to [...]

  • Page 3

    69-1436–1 3 T801 1R PROGRAMMABLE HEA T PUMP THERMOST A T Fig. 4. Restrict wiring to shaded area. Fig. 5. T8011R two stage heat, one stage cool wiring diagram with manual changeover. KEEP WIRING IN SHADED AREA MOUNTING SCREW HOLE MOUNTING SCREW HOLE WIRING ENTRANCE HOLE M11331A G C R Y W1 L W2 E B O 1 NOT ALL MODELS HAVE BOTH O AND B TERMINALS. 1 [...]

  • Page 4

    69-1436–1 4 T801 1R PROGRAMMABLE HEA T PUMP THERMOST A T Mounting Thermostat To Wallplate 1. Slide SYSTEM switch to the Off position. 2. Engage the tabs at the top of the thermostat and wallplate. 3. Swing down the thermostat and press the lower edge of the thermostat onto the wallplate to latch. See Fig. 6. Fig. 6. Mounting thermostat to wallpla[...]

  • Page 5

    69-1436–1 5 T801 1R PROGRAMMABLE HEA T PUMP THERMOST A T 3. Setting Heat Cycle Rate (see Table 2 for cycle rate options and equipment). a. Press the ▲ key to display the current heat cycle rate setting of 3, 4, 5, 6, 9 or 12 cph. b. If the desired cycle rate is displayed, press the ▲ key to exit the installer setup. c. To change the heat cycl[...]

  • Page 6

    69-1436–1 6 T801 1R PROGRAMMABLE HEA T PUMP THERMOST A T Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 69-1436–1 G.H. Rev . 2-02 Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Setting Current Time and Day 1. To Set Current Time. a. Press Select [...]