Honeywell V2000 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell V2000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell V2000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell V2000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell V2000 should contain:
- informations concerning technical data of Honeywell V2000
- name of the manufacturer and a year of construction of the Honeywell V2000 item
- rules of operation, control and maintenance of the Honeywell V2000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell V2000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell V2000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell V2000.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell V2000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    PRODUCT DATA 62-3048—2 MV100 Electric Controllers T100, T200 Thermostatic Controllers and V2000 Radiator V alves APPLICATION The MV100, T100, T200 Controllers, when paired with V2000 Radiator V alves, provide auto matic temperature control by modulating the flow of steam or hot water through free- standing radiators, convectors, and other heating[...]

  • Page 2

    MV100 ELECTRIC CONTROLLERS T100 , T200 THERMOST ATIC CONTROLLERS AND V2000 RADIATOR V ALVES 62-3048—2 2 ORDERING INFORMATION When purchasing replacement and modernizat io n products from your TRADELINE® whol esale r or distributor , re fer to the TRADELINE® Catalog or price sheets for complete ordering number . If you have additional questions,[...]

  • Page 3

    MV100 ELECTRIC CONTROLLERS T100, T 200 THERMOSTATIC CONTROLLERS AND V2000 RADIATOR V ALVES 3 62-3048—2 Fig. 1. MV10 0, T100 and T 200 dimensio ns in in. (mm). 3-5/16 (84) MAX. M12928 2-1/8 (54) CAPILLARY TUBE LENGTH 6-1/2 FT (2 m) 2 (50) T100F 3-5/16 (84) MAX. 2 (50) 2-1/8 (54) 1 (25) M12925A TOP T100A 3 (77) 2 (50) M12929 TOP T100M CAPILLARY TUB[...]

  • Page 4

    MV100 ELECTRIC CONTROLLERS T100 , T200 THERMOST ATIC CONTROLLERS AND V2000 RADIATOR V ALVES 62-3048—2 4 T a ble 1. T100,T200 Mo dels. a Mount the unit horizontally on the valve body for accura te temperature regulati on. T ab le 2. V2000 Models . Fig. 2. V200 0 dimensions. NOTE: Refer to T able 3 for detailed valve dimensions for each valve size.[...]

  • Page 5

    MV100 ELECTRIC CONTROLLERS T100, T 200 THERMOSTATIC CONTROLLERS AND V2000 RADIATOR V ALVES 5 62-3048—2 T able 3. V alve Dimensions. a B Max dimension is with T100A co ntrol installed, except for the V2042H, for which it is without the steam/ai r vent installed. Connections: Inlets Available: Internally threa ded. Sweat (1/2 in. and 3/4 in. only).[...]

  • Page 6

    MV100 ELECTRIC CONTROLLERS T100 , T200 THERMOST ATIC CONTROLLERS AND V2000 RADIATOR V ALVES 62-3048—2 6 Pre-setting and Balancing Flow Through V alve Body . Close valve with straight blade screw driver by turning black pre-setting ring clockwise. Fig. 4. Clos ing valve. When closed, the position of the screwdriver slot equals pre- setting zero. M[...]

  • Page 7

    MV100 ELECTRIC CONTROLLERS T100, T 200 THERMOSTATIC CONTROLLERS AND V2000 RADIATOR V ALVES 7 62-3048—2 T ypical Applications T able 5. Figure References to T ypi cal Applicati ons. Fig. 8. Fig. 9. Fig. 10. Fig. 1 1. One-pipe steam syste m. Fig. 12. Fig. 13. Application Figure No. Controller V alve 8 T100A, T100M, T200, MV100 V2040D 9 T100A, T100M[...]

  • Page 8

    MV100 ELECTRIC CONTROLLERS T100 , T200 THERMOST ATIC CONTROLLERS AND V2000 RADIATOR V ALVES 62-3048—2 8 Fig. 14. Fig. 15. Fig. 16. Fig. 17. Fig. 18. Fig. 19. Fig. 20. Location and Mounting Because these controls are thermostats that have sensors that measure air temperature in the immediate vicinity , it is critical to select an appropriate insta[...]

  • Page 9

    MV100 ELECTRIC CONTROLLERS T100, T 200 THERMOSTATIC CONTROLLERS AND V2000 RADIATOR V ALVES 9 62-3048—2 Fig. 21. Horizontal-b ody V2000 applicatio n. Install controllers with external sensors in any posi tion. The sensor can easily be mounted in a position to measure and control the room air temperature. NOTE: When temperature of medium exceeds 19[...]

  • Page 10

    MV100 ELECTRIC CONTROLLERS T100 , T200 THERMOST ATIC CONTROLLERS AND V2000 RADIATOR V ALVES 62-3048—2 10 T ab le 6. T100 and T200 Settings and Cor responding T emperatures in °F (°C). a Setting not marked on dial. Setpoint Locking or Limiting (T100A,F ,M only) A single temperature o r range-limiting lock is available for the T100A,F ,M. See Acc[...]

  • Page 11

    MV100 ELECTRIC CONTROLLERS T100, T 200 THERMOSTATIC CONTROLLERS AND V2000 RADIATOR V ALVES 11 62-3048—2 NOTE: — While the T100 is satisfied, the V2042H is closed and the radiator remains airlocked. Thus, no steam can enter the ra diator . The airlocked condition remains until th e T100 calls for heat, at which point the system operate s as desc[...]

  • Page 12

    MV100 ELECTRIC CONTROLLERS T100 , T200 THERMOST ATIC CONTROLLERS AND V2000 RADIATOR V ALVES 62-3048—2 12 T ROUBLESHOOTING Refer to T able 6 for troubleshooting details. T able 7. T100/V2000 T roubleshooting. Symptom Possible C ause Solution Not all sections o f the radiator are heating. Many radiators are oversized and not all sections heat to ma[...]

  • Page 13

    MV100 ELECTRIC CONTROLLERS T100, T 200 THERMOSTATIC CONTROLLERS AND V2000 RADIATOR V ALVES 13 62-3048—2 PRESSURIZED V ALVE CARTRIDGE REPLACEMENT The V A8200A001 V alve Cartridge Changing T ool enables the user to remove, and cl ean or replace the valve cartridge while the valve remains pressu rized. Boiler shutdown is not required. WARNING Severe[...]

  • Page 14

    62-3048—2 14[...]

  • Page 15

    15 62-3048—2[...]

  • Page 16

    Automation and Co ntrol Solutions Honeywell Internation al Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Dri ve North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 customer.honeywell.com ® U.S. Registered T rademark © 2006 Honeywell International I nc. 62-3048—2 G .R. Rev . 02-06[...]