Honeywell Y8150 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell Y8150, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell Y8150 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell Y8150. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell Y8150 should contain:
- informations concerning technical data of Honeywell Y8150
- name of the manufacturer and a year of construction of the Honeywell Y8150 item
- rules of operation, control and maintenance of the Honeywell Y8150 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell Y8150 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell Y8150, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell Y8150.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell Y8150 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    PRODUCT DAT A Put Bar Code Here 68-0282-07 Y8150 Fresh Air V entilation System, W8150 Fresh Air V entilation Control APPLICATION The Y8150 Fresh Air V entilation System, W8150 Fresh Air V entilation Control provide fres h air to a home. The control operates a fresh air intake damper and, when necessary , activates the main HV AC blower to efficient[...]

  • Page 2

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL 68-0282—0 7 2 SPECIFICATIONS Y8150 includes: W8150A Fresh Air V entil ation Control. EARD6 Fresh Air Damper . A T120B T ransformer . Mounting hardware for control. Homeowner information label. W8150 includes: W8150 Fresh Air V entil ation Control. Mounting hardware for co[...]

  • Page 3

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR VENTILATION CONTROL 3 68-0282—07 W8150 QUICK GUIDE No. Name Description Function 1G F Equipment fan Allows W8150 to pass thermost at calls and, when necessary , turn on system fan for ventilation. This should be the only connecti on to G on the HV AC equipment. 2R C 24 V ac cooling system powe[...]

  • Page 4

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL 68-0282—0 7 4 INST ALLATION A fresh air duct and damper must be installed between the outdoors and the return side of the HV AC equipment. The W8150 control will be mounted near th e HV AC system and wired between the thermost at and the fan control. Y ou will need… •[...]

  • Page 5

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR VENTILATION CONTROL 5 68-0282—07 Inst alling fresh ai r damper , ducting, and control… 1. Disconnect power from HV AC system. 2. Install the weather hood, du cting, and damper followi ng local practices. Be sure al l duct and insulation seams are tightly sealed. 3. Mount the transformer and [...]

  • Page 6

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL 68-0282—0 7 6 Measuring airflow… 1. Make sure all HV AC system air filters are clean and installed. 2. Push T est button: • Control opens damper and turns on HV AC fan for three minutes. • A red or green light is flashing; you can now me asure airflow . 3. Follow in[...]

  • Page 7

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR VENTILATION CONTROL 7 68-0282—07 Setting the control... 1. Be sure power is turned on. 2. Set the V entilation S tandard on the con trol. 3. Set the bedrooms dial. 4. Set the area (sq f t) dial. 5. Set the airflow (cfm) dial. 6. Press the test button and observe the lights: Green light is flas[...]

  • Page 8

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL 68-0282—0 7 8 CHECKOUT In this section, make sure the ventilation system is operating correctly . 1. On thermostat, set Fan swit ch to Auto and System switch to Off . 2. Set any remote swi tches throughout the house in the Off position. 3. On the W8150, set the control sw[...]

  • Page 9

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR VENTILATION CONTROL 9 68-0282—07 HV AC fan is running all the time Device is set to override • Move switch to On position to allow for automatic opera tion. Remote switch is on • Adjust remote switch to desired position. Thermostat Fan switch is in On position • Normal ope ration. HV AC [...]

  • Page 10

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL 68-0282—0 7 10 WIRING DIAGRAMS Consult thermo stat Installation Instructions for alternate terminal designations. Fig. 1. Single transformer , conventiona l system. Fig. 2. Dual tran sforme r , conventional system. Fig. 3. Multi-st age conventional sys tem. Fig. 4. Wiring[...]

  • Page 11

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR VENTILATION CONTROL 11 68-0282—07 Fig. 5. Wiring hea t pump with emergency heat. Fig. 6. Wiri ng with a PC8900. Fig. 7. Using a remote switch or timer . Fig. 8. W iring to an HR V/ERV . Fig. 9. Wiring an exhaust fan. Wake Room System Fan Heat Auto AM DST Tue Y C RW 2 E G O Y 1 W 1 C RW 2 E G O[...]

  • Page 12

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL Automation and Co ntrol Solutions Honeywell Internationa l Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Toronto, Ontario M1V 4Z9 customer.honeywell.com ® U.S. Regi stered T rademark © 201 1 Honeywell Inte rnat[...]