Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Hoshizaki KM-900MRF3, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hoshizaki KM-900MRF3 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Hoshizaki KM-900MRF3. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Hoshizaki KM-900MRF3 should contain:
- informations concerning technical data of Hoshizaki KM-900MRF3
- name of the manufacturer and a year of construction of the Hoshizaki KM-900MRF3 item
- rules of operation, control and maintenance of the Hoshizaki KM-900MRF3 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hoshizaki KM-900MRF3 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hoshizaki KM-900MRF3, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hoshizaki service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hoshizaki KM-900MRF3.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Hoshizaki KM-900MRF3 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SER VICE MANUAL NO.: ISSUED: REVISED: MAR. 19, 1999 73083 HOSHIZAKI MODULAR CRESCENT CUBER MODELS KM-900MAF KM-900MWF KM-900MRF KM-900MRF3 DEC. 15, 2003[...]
-
Page 2
2 IMPORT ANT Only qualified service technicians should attempt to service or maintain this icemaker. No service or maintenance should be undertaken until the technician has thoroughly read this Service Manual. HOSHIZAKI AMERICA, INC. 618 Highway 74 South Peachtree City , GA 30269 Attn: HOSHIZAKI T echnical Support Department Phone: 1-800-233-1940 T[...]
-
Page 3
3 Please review this manual. It should be read carefully before the icemaker is serviced or maintenance operations are performed. Only qualified service technicians should service and maintain the icemaker. This manual should be made available to the technician prior to service or maintenance. CONTENTS PAGE I. SPECIFICATIONS .......................[...]
-
Page 4
4 IV. SERVICE DIAGNOSIS ........................................................................................... 40 1. NO ICE PRODUCTION ........................................................................................ 40 2. EVAPORATOR IS FROZEN UP .......................................................................... 43 3. LOW ICE PR[...]
-
Page 5
5 I. SPECIFICATIONS 1. KM-900MAF * We reserve the right to make changes in specifications and design without prior notice.[...]
-
Page 6
6 2. KM-900MWF * We reserve the right to make changes in specifications and design without prior notice.[...]
-
Page 7
7 3. KM-900MRF * We reserve the right to make changes in specifications and design without prior notice.[...]
-
Page 8
8 4. KM-900MRF3 * We reserve the right to make changes in specifications and design without prior notice.[...]
-
Page 9
9 5. CONDENSING UNIT URC-12F[...]
-
Page 10
10 SPECIFICATIONS MODEL: URC-12F EXTERIOR DIMENSIONS (W x D x H) REFRIGERANT CHARGE URC-12F WEIGHT CONNECTIONS REFRIGERANT ELECTRICAL CONDENSER HEAD PRESSURE CONTROL AMBIENT CONDITION Galvanized Steel 35 - 11/16” x 15-11/16” x 21-15/16” (907.2 x 398 x 557.8 mm) R404A 4 lbs. 7 oz. (2000 g) Net 80 lbs. (36 kg) Shipping 87 lbs. (39 kg) One Shot [...]
-
Page 11
11 II. GENERAL INFORMA TION 1. CONSTRUCTION [a] KM-900MAF[...]
-
Page 12
12 [b] KM-900MWF[...]
-
Page 13
13 [c] KM-900MRF[...]
-
Page 14
14 [d] KM-900MRF3[...]
-
Page 15
15 2. CONTROLLER BOARD [a] SOLID-STATE CONTROL 1) A HOSHIZAKI exclusive solid-state control is employed in KM-900MAF, KM-900MWF, KM-900MRF and KM-900MRF3 Modular Crescent Cubers. 2) A Printed Circuit Board (hereafter called “Controller Board”) includes a stable and high quality control system. 3) All models are pretested and factory-adjusted. [[...]
-
Page 16
16 2) Defrost Timer The defrost cycle starts when the Float Switch opens and completes the freeze cycle. But the Defrost Timer does not start counting until the Thermistor senses 48°F at the Evaporator outlet. The period from the end of the freeze cycle up to the point of the Thermistor's sensing varies depending on the ambient and water temp[...]
-
Page 17
17 problem occurs. At startup a 5 second delay occurs while the board conducts an internal timer check. A short beep occurs when the power switch is turned ON or OFF. The green LED’s 1-4 represent the corresponding relays and energize and sequence 5 seconds from initial startup as follows: Sequence Step LED’s on Length: Min. Max. Avg. 1 Minute [...]
-
Page 18
18 (Control Product s HOS-001A Board) to the K1 connector. If there is a white wire, place the switch in the C position. If this switch is placed in the wrong position either the compressor contactor will remain ener- gized with the control switch OFF or the unit will not start. The dip switches should be adjusted per the adjustment chart published[...]
-
Page 19
19 [c] SEQUENCE 1st Cycle 1. Unit energized and Control Switch to “ICE” position. Water supply cycle starts. 2. After 1 minute, Defrost cycle starts. 3. Thermistor reads 48° F. Defrost Timer starts counting. IMPORTANT Water Valve opening is limited to 6 minutes. & 5. After the first 5 minutes in freeze cycle. Ready to complete freeze cycle[...]
-
Page 20
20 2nd Cycle and after with pump drain IMPORTANT Freeze cycle time is limited to 60 minutes even if Float Switch does not open. 1. Float Switch opens and signals to complete freeze cycle. Drain timer starts counting. 2. Drain timer stops counting. Pump drain is completed 3. Thermistor reads 48° F. Defrost Timer starts counting. IMPORTANT Water Val[...]
-
Page 21
21 2nd Cycle and after with no pump drain IMPORTANT Freeze cycle time is limited to 60 minutes even if Float Switch does not open. 1. Float Switch opens and signals to complete freeze cycle. 2. Thermistor reads 48° F. Defrost Timer starts counting. IMPORTANT Water Valve opening is limited to 6 minutes. 4. After the first 5 minutes in freeze cycle.[...]
-
Page 22
22 DIP SWITCH NO. 1 2 3 4 5 6 7 8 9 10 KM-900MRF/3 OFF OFF ON OFF ON ON OFF OFF OFF ON KM-900MAF, OFF OFF ON OFF ON ON OFF OFF OFF ON KM-900MWF [d] CONTROLS AND ADJUSTMENTS The Dip Switch is factory-adjusted to the following positions: Switch Nos. 1 and 2: Used for adjustment of the Defrost Timer. The Defrost Timer starts counting when the Thermist[...]
-
Page 23
23 1) Defrost Control A thermistor (Semiconductor) is used for a defrost control sensor. The resistance var- ies depending on the Suction Line temperatures. The Thermistor detects the tempera- ture of the Evaporator outlet to start the Defrost Timer. No adjustment is required. If necessary, check for resistance between Thermistor leads, and visuall[...]
-
Page 24
24 3) Drain Timer The Drain Timer is factory-adjusted, and no adjustment is required. SETTING TIME Dip Switch Dip Switch No. 3 No. 4 T1 T2 OFF OFF 10 seconds 150 seconds ON OFF 10 seconds 180 seconds OFF ON 10 seconds 120 seconds ON ON 20 seconds 180 seconds T1: Time to drain the Water Tank T2: Time to restrain defrost completion 4) Drain Counter C[...]
-
Page 25
25 6) Bin Control CAUTION When the ambient temperature is below 45°F, the Bin Control Thermostat operates to stop the icemaker even if the Ice Storage Bin is empty. When the Thermostat is set in the prohibited range, the icemaker operates continuously even if the Ice Storage Bin is filled with ice. Setting in the prohibited range might cause sever[...]
-
Page 26
26 (iv) After Step (iii), de-energize the unit and confirm that the Defrost Timer is in the minimum position. Disconnect the resistor from the Controller Board, and ener- gize the unit. After the 1 minute water supply cycle, the defrost cycle starts. Re-connect a 1.5 k Ω - 3.5 k Ω resistor to the Connector K3 (pins #1 and #2) after the first 2 [...]
-
Page 27
27 III. TECHNICAL INFORMA TION 1. WATER CIRCUIT AND REFRIGERANT CIRCUIT [a] KM-900MAF[...]
-
Page 28
28 [b] KM-900MWF[...]
-
Page 29
29 [c] KM-900MRF and KM-900MRF3[...]
-
Page 30
30 2. WIRING DIAGRAMS [a] KM-900MAF Note: Pressure Switch Cut-out 412 ± PSIG Cut-in 327 ± 21 PSIG 21 0[...]
-
Page 31
31 [b] KM-900MWF Note: Pressure Switch Cut-out 412 ± PSIG Cut-in 327 ± 21 PSIG 21 0[...]
-
Page 32
32 [c] KM-900MRF Note: Pressure Switch Cut-out 412 ± PSIG Cut-in 327 ± 21 PSIG 21 0[...]
-
Page 33
33 [d] KM-900MRF3 Note: Pressure Switch Cut-out 412 ± PSIG Cut-in 327 ± 21 PSIG 21 0[...]
-
Page 34
34 3. TIMING CHART Control Sw. in ICE Bin Thermo- stat ON Pressure Sw. ON Overheat Protect Reset Hi Temp Mid Temp Lo Temp Too Lo Temp Normal Too Hi Temp Lo Water Max. Min. 60 min 5 min Min. Max. Max. 2 min 6 min 6 min Max. 20 min Time Up (60 sec) If Float Sw. is OFF From Defrost Cycle When Control Sw. is turned OFF, Pressure Sw. is OFF, or Thermist[...]
-
Page 35
35 To Freeze Cycle To Stand-by Cycle (When Control Sw. is turned OFF, Pressure Sw. is OFF, or Thermistor Temp. exceeds t1.) From Freeze Cycle Control Sw. in WASH Min. Max. Max. 3 min 6 min 6 min Max. 20 min *1 The Pump Motor waits for 2 seconds before starting a drain cycle. See “II. 2. [d] CONTROLS AND ADJUSTMENTS.” *2 The icemaker does not co[...]
-
Page 36
36 4. PERFORMANCE DATA [a] KM-900MAF Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only. * We reserve the right to make changes in specifications and design without prior notice.[...]
-
Page 37
37 [b] KM-900MWF Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only. * We reserve the right to make changes in specifications and design without prior notice.[...]
-
Page 38
38 [c] KM-900MRF Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only. * We reserve the right to make changes in specifications and design without prior notice.[...]
-
Page 39
39 [b] KM-900MRF3 Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only. * We reserve the right to make changes in specifications and design without prior notice.[...]
-
Page 40
40 PROBLEM POSSIBLE CAUSE REMEDY [1] The icemaker a) Power Supply 1. “OFF” position. 1. Move to “ON” position will not start 2. Loose connections. 2. Tighten 3. Bad contacts. 3. Check for continuity and replace. 4. Voltage too high. 4. Check and get recommended voltage. b) Fuse (Inside Fused 1. Blown out. 1. Check for short circuit Disconne[...]
-
Page 41
41 PROBLEM POSSIBLE CAUSE REMEDY l) Controller Board 1. Defective 1. See “II.2[e] CHECKING CONTROLLER BOARD.” m) Interlock Switch 1. “OFF” position. 1. Move to “ON” position. (Cleaning Valve) 2. Bad contacts. 2. Check for continuity and replace. [2] Water a) Float switch 1. Connector disconnected. 1. Place in position. continues to 2. L[...]
-
Page 42
42 PROBLEM POSSIBLE CAUSE REMEDY [4] Water a) Water Solenoid 1. Diaphragm does not close. 1. Check for water leaks continues to Valve with icemaker off. be supplied in b) Controller Board 1. Defective. 1. See “II.2.[e] CHECKING freeze cycle. CONTROLLER BOARD.” [5] No water a) Water Supply Line 1. Water pressure too low and 1. Check and get come[...]
-
Page 43
43 PROBLEM POSSIBLE CAUSE REMEDY [1] Freeze cycle a) See chart 1 - [3], and check dirty Air Filter or Condenser, ambient or water time is long. temperature, water pressure, Water Regulator or refrigerant charge. b) See chart 2 - [1], and check Float Switch, Water Solenoid Valve or Controller Board. [2] Harvest cycle a) See chart 2 - [2], and check [...]
-
Page 44
44 PROBLEM POSSIBLE CAUSE REMEDY [1] Icemaker will a) Bin Control 1. Set too cold. 1. Adjust warmer. not stop when Thermostat 2. Defective. 2. Replace. bin is filled with ice. [2] Abnormal a) Pump Motor 1. Bearings worn out. 1. Replace. noise b) Fan Motor 1. Bearings worn out. 1. Replace. 2. Fan blade deformed. 2. Replace fan blade. 3. Fan blade do[...]
-
Page 45
45 V. REMOVAL AND REPLACEMENT OF COMPONENTS IMPORTANT Ensure all components, fasteners and thumbscrews are securely in place after the equipment is serviced. IMPORTANT 1. The Polyol Ester (POE) oils used in R-404A units can absorb moisture quickly. Therefore it is important to prevent moisture from entering the system when replacing or servicing pa[...]
-
Page 46
46 5) Disconnect the Vacuum Pump, and attach a Refrigerant Service Cylinder to the High- side line. Remember to loosen the connection, and purge the air from the Hose. See the Nameplate for the required refrigerant charge. Hoshizaki recommends only virgin refrigerant or reclaimed refrigerant which meets ARI Standard No. 700-88 be used. 6) A liquid [...]
-
Page 47
47 3. REMOV AL AND REPLACEMENT OF COMPRESSOR IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. Note: When replacing a Compressor with a defective winding, be sure to install the new Start Capacitor and Start Relay supplied w[...]
-
Page 48
48 15) Evacuate the system, and charge it with refrigerant. For air-cooled and water-cooled models, see the Nameplate for the required refrigerant charge. For remote air-cooled models, see the Charge Label in the machine compartment. 16) Connect the Terminals, and replace the Terminal Cover in its correct position. 17) Replace the panels in their c[...]
-
Page 49
49 4. REMOV AL AND REPLACEMENT OF DRIER IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. 1) Turn off the power supply. 2) Remove the panels. 3) Recover the refrigerant and store it in an approved container. 4) Remove the Dr[...]
-
Page 50
50 3) Recover the refrigerant and store it in an approved container. 4) Remove the insulation and the Expansion Valve Bulb on the suction line. 5) Remove the Expansion Valve Cover, and disconnect the Expansion Valve using brazing equipment. 6) Braze the new Expansion Valve, with nitrogen gas flowing at the pressure of 3-4 PSIG. W ARNING Always prot[...]
-
Page 51
51 IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. 1) Turn off the power supply. 2) Remove the panels. 3) Recover the refrigerant and store it in an approved container. 4) Remove the screw and the Solenoid. 5) Disconnect t[...]
-
Page 52
52 7. REMOV AL AND REPLACEMENT OF EV APORA TOR IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repairs or replacement have been made. 1) Turn off the power supply. 2) Remove the panels and the Top Insulation over the Evaporator. 3) Recover the refrigerant and[...]
-
Page 53
53 8. REMOV AL AND REPLACEMENT OF W A TER REGULA TING V AL VE - W A TER-COOLED MODEL ONL Y IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. 1) Turn off the power supply. 2) Close the Water Supply Line Shut-off Valve. 3) Rem[...]
-
Page 54
54 9. ADJUSTMENT OF W A TER REGULA TING V AL VE - W A TER-COOLED MODEL ONL Y The Water Regulating Valve (also called “WATER REGULATOR”) is factory-adjusted. No adjustment is required under normal use. Adjust the Water Regulator, if necessary, using the following procedures. 1) Attach a pressure gauge to the high-side line of the system. Or prep[...]
-
Page 55
55 10. REMOV AL AND REPLACEMENT OF CONDENSING PRESSURE REGULA T OR (C.P .R.) - REMOTE AIR-COOLED MODEL ONL Y IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repair or replacement has been made. 1) Turn off the power supply. 2) Remove the panels from the remot[...]
-
Page 56
56 1 1. REMOV AL AND REPLACEMENT OF THERMIST OR CAUTION 1. Fragile, handle very carefully. 2. Always use a recommended sealant (High Thermal Conductive Type), Model KE4560RTV manufactured by SHINETSU SILICONE, Part Code 60Y000-11, or Part Code 4A0683-01 equivalent. 3. Always use a recommended foam insulation (Non-absorbent Type) or equivalent. 4. D[...]
-
Page 57
57 Min. 4-3/4" Liquid Bypass Flow 10) Secure the insulation using the Plastic Cable Ties. 11) Connect the Thermistor leads through the bushing of the Control Box to the K3 Connector on the Controller Board. Note: Do not cut the leads of the Thermistor while installing it. 12) Replace the Control Box Cover and the panels in their correct positi[...]
-
Page 58
58 13. REMOV AL AND REPLACEMENT OF W A TER V AL VE 1) Turn off the power supply. 2) Close the Water Supply Line Shut-off Valve. 3) Remove the Front Panel. 4) Remove the Valve Outlet Tubing by releasing the Clamp. 5) Remove the Bracket from the unit. 6) Remove the Fitting Nut and Water Valve. 7) Disconnect the Terminals from the Water Valve. 8) Inst[...]
-
Page 59
59 8) Remove the closed end connectors from the Pump Motor leads. 9) Remove the two screws and the Pump Motor Bracket. 10) Remove the Pump Housing, and check the Impeller. 11) If the Impeller is defective, install a new Impeller. 12) Install the new motor or new parts, and replace the removed parts in the reverse order of which they were removed. 1[...]
-
Page 60
60 VI. MAINTENANCE AND CLEANING INSTRUCTIONS IMPORTANT Ensure all components, fasteners and thumbscrews are securely in place after any maintenance or cleaning is done to the equipment. 1. PREPARING THE ICEMAKER FOR LONG STORAGE WARNING When shutting off the icemaker for an extended time, drain out all water from the water tank and remove the ice f[...]
-
Page 61
61 [2] Remove the water from the potable water supply line: 1) Remove the Front Panel. (Except water-cooled model) 2) Move the Control Switch, on the Control Box, to the “OFF” position. 3) Wait 3 minutes. 4) Close the Potable Water Supply Line Shut-off Valve and open the Potable Water Supply Line Drain Valve. 5) Allow the line to drain by gravi[...]
-
Page 62
62 CLOSED POSITION OPEN POSITION 2. CLEANING IMPORTANT Ensure all components, fasteners and thumbscrews are securely in place after any maintenance or cleaning is done to the equipment. WARNING 1. HOSHIZAKI recommends cleaning this unit at least once a year. More frequent cleaning, however, may be required in some existing water conditions. 2. To p[...]
-
Page 63
63 [a] CLEANING PROCEDURE 1) Dilute 16 fl. oz. of the recommended cleaner Hoshizaki “Scale Away” or “LIME-A-WAY” (Economics Laboratory, Inc.) with 3 gallons of water. 2) Remove all ice from the Evaporator and the Storage Bin. Note: To remove cubes on the Evaporator, turn off the power supply and turn it on after 3 minutes. The defrost cycle[...]
-
Page 64
64 20) Turn on the power supply to fill the Water Tank with water. 21) Turn off the power supply after 3 minutes. 22) Remove the Front Panel, and fully open the Cleaning Valve. 23) Move the Control Switchto the “Wash” position. 24) Replace the Front Panel in its correct position. 25) Turn on the power supply to rise off the cleaning solution. 2[...]
-
Page 65
65 8) Drain the Water Tank. See the above step 5) in “[a] CLEANING PROCEDURE.” 9) Replace the removed parts and the Insulation Panel in their correct positions. 10) Repeat the above steps 15) through 28) in “[a] CLEANING PROCEDURE” two times to rinse thoroughly. 11) Close the Cleaning Valve. 12) Move the Control Switch to the “ICE” posi[...]