Go to page of
Similar user manuals
-
Ice Maker
Hoshizaki F-801MWH/-C
58 pages 0.94 mb -
Ice Maker
Hoshizaki KML-700MWH-M
20 pages 1.05 mb -
Ice Maker
Hoshizaki KM-800MWE
84 pages 2.49 mb -
Ice Maker
Hoshizaki KM-2500SWH3
61 pages 1.88 mb -
Ice Maker
Hoshizaki KM-630MWH
67 pages 1.21 mb -
Ice Maker
Hoshizaki dcm-75ibah
61 pages 3.3 mb -
Ice Maker
Hoshizaki AM-50BAE-DS
13 pages 1.52 mb -
Ice Maker
Hoshizaki KM-650MRH
54 pages 1.39 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Hoshizaki MODULAR FLAKER F-1000MAF/-C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hoshizaki MODULAR FLAKER F-1000MAF/-C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Hoshizaki MODULAR FLAKER F-1000MAF/-C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Hoshizaki MODULAR FLAKER F-1000MAF/-C should contain:
- informations concerning technical data of Hoshizaki MODULAR FLAKER F-1000MAF/-C
- name of the manufacturer and a year of construction of the Hoshizaki MODULAR FLAKER F-1000MAF/-C item
- rules of operation, control and maintenance of the Hoshizaki MODULAR FLAKER F-1000MAF/-C item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hoshizaki MODULAR FLAKER F-1000MAF/-C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hoshizaki MODULAR FLAKER F-1000MAF/-C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hoshizaki service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hoshizaki MODULAR FLAKER F-1000MAF/-C.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Hoshizaki MODULAR FLAKER F-1000MAF/-C item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SER VICE MANUAL ISSUED: JAN. 20, 1999 MODEL HOSHIZAKI MODULAR FLAKER F-1000MAF/-C F-1000MWF/-C F-1000MRF/-C F-1000MLF/-C NO: 73075 REVISED: DEC. 17, 2003[...]
-
Page 2
2 HOSHIZAKI AMERICA, INC. 618 Highway 74 South Peachtree City , GA 30269 Attn: HOSHIZAKI T echnical Support Department Phone: 1-800-233-1940 T echnical Service (770) 487-2331 Fax: (770) 487-3360 NOTE: T o expedite assist ance, all correspondence/communication MUST include the following information: • Model Number • Serial Number • Complete an[...]
-
Page 3
3 CONTENTS PAGE I. SPECIFICATIONS .................................................................................................... 5 1. ICEMAKER ............................................................................................................. 5 F-1000MAF ...............................................................................[...]
-
Page 4
4 F-1000MWF ......................................................................................................... 42 F-1000MRF .......................................................................................................... 4 3 F-1000MLF ..................................................................................................[...]
-
Page 5
5 I. SPECIFICA TION 1. ICEMAKER F-1000MAF AC SUPPLY VOLTAGE 208-23 0/ 60/1 (3 wire with neut r al f or 115V) COMPRESSOR 240 V 4.2 RLA 34 LRA GEAR MOT OR 120 V 1.6 FLA 1/6 HP FAN MO T OR 115 V 0.85F LA 1/15 HP OT HER 120 V 0.03A MAXIMUM FUSE SIZE 15 A MAX. HACR BREAKER (USA ONLY) 15 A MAX. CIRC. BREAKER (CANADA ONLY) 15 A MINI MUM CI RCUIT AM PACITY[...]
-
Page 6
6 F-1000MWF AC SUPPLY VOLT AGE 208-230/ 60/1 ( 3 wire with neut ral f or 115V) COMPRESS OR 240 V 4.2 RLA 34 LRA GEA R MOTOR 120 V 1.6 FLA 1/6 HP OTHER 120 V 0.03A MAX IMUM F US E SIZ E 15 A MAX. HACR BREAKER (USA ONLY) 15 A MAX. CIRC. BREAKER (CANADA ONLY ) 15 A MINIMUM C IRC UIT AM PA C ITY 15 A APPROXIMATE I CE PRODUCTION Ambient W ATER TEMP. ( ?[...]
-
Page 7
7 F-1000MRF AC SU PPLY VO LT AG E 208-230/60/1 (3 wir e with neutral for 115V) CO M PRE S SO R 240 V 4.2 RLA 34 LRA GE A R M O T O R 120 V 1.6 F LA 1/6 H P FA N MO TO R R E M O T E 120 V 3 A MA X OT HE R 120 V 0.03A MAXIMUM FUSE SI ZE 15 A MAX. HACR BREAKER (USA ONLY) 15 A MAX. CIRC. BREAKE R (CANAD A O NLY) 15 A MI NIMUM CIRC UIT A MPAC ITY 15 A A[...]
-
Page 8
8 F-1000MLF AC SUPPLY VOLTAGE 115 /60/1 GEAR MOT OR 120 V 1.6 FLA 1/6 HP OTH ER 120 V 0.03A MAXIMUM FU SE SIZE 15 A MAX. HACR BREAKER (U SA ONLY) 15 A MAX. CIRC. BR EAKER (CANADA ONLY) 15 A MINI MUM C IRCUIT A MPACI TY 15 A APPROXIMATE IC E PRODUCTION Ambient W AT ER T EMP. (F) PER 24 HR. T em p. (F) 50 70 90 lbs./day ( kg/day ) 70 1150 (522) 1035 [...]
-
Page 9
9 F-1000MAF-C AC SUPPLY VOLTAG E 208-230 /60/1 (3 wire with neutral for 115V) COMPRESSOR 240 V 4.2 RLA 34 LRA GEAR MOT OR 120 V 1.6 FLA 1/6 HP FAN MO TO R 115 V 0.85F LA 1/15 HP OT HER 120 V 0.03A MAXIMUM FU SE SIZE 15 A MAX. HACR BREAKER (U SA ONLY) 15 A MAX. CIRC. BR EAKER (CANADA ONLY) 15 A MINI MUM C IRCUIT A MPAC ITY 15 A APPROXIMATE IC E PROD[...]
-
Page 10
10 F-1000MWF-C AC SUPPLY VOLTAGE 208-230 /60/1 (3 wire with neutral f or 115V) COMPRESSOR 240 V 4.2 RLA 34 LRA GEAR MOTOR 120 V 1.6 FLA 1/6 HP OTHER 120 V 0.03A MAXIMUM F USE SIZE 15 A MAX. HACR BREAKER (USA ONLY) 15 A MAX. CIRC. BREAKER (CANADA ONLY) 15 A MINIMU M CIRCUIT A MPAC IT Y 15 A APPROXIMATE ICE PRODUCT ION Ambient W ATER T EMP. (°F) PER[...]
-
Page 11
11 F-1000MRF-C AC SUPPLY VOLTAG E 208-230/60/1 (3 wire with neutral for 115V) COMPRE SSOR 240 V 4.2 RLA 34 LRA GEAR M OTOR 120 V 1.6 FLA 1/6 HP FA N MOTO R REM OTE 12 0 V 3A MAX OTHER 120 V 0.0 3A MAXIMUM FUSE SIZE 15 A MAX. HACR BREAKER (USA ONLY ) 15 A MAX. CIRC. BREAKER (CANADA ONLY) 1 5 A MINIMUM CIRCUIT AMPACITY 15 A APPROXIMAT E ICE PRODUCT I[...]
-
Page 12
12 F-1000MLF-C AC SUPPLY VOLTAG E 115 /60/1 GEAR M OT OR 120 V 1.6 FLA 1/6 HP OT HER 120 V 0.03A MAXIMUM FUSE SIZE 15 A MAX. HACR BREAKER (USA ONLY) 15 A MAX. CIRC. BREAKER (CANADA ONLY) 15 A MINI MUM C IRCUI T AMPA CITY 15 A APPROXIMATE ICE PRODUCT ION Ambient W ATER T EMP. (F) PER 24 HR. T em p. (F) 50 70 90 lbs./day ( kg/day ) 70 1020 (463) 945 [...]
-
Page 13
13 2. CONDENSER UNIT URC-6F[...]
-
Page 14
14 SPECIFICATIONS MODEL: URC-6F EXTERIOR Galvanized Steel DIMENSIONS (W x D x H) 21-15/16" x 15-11/16" x 17-7/8" (557 x 398 x 454 mm) REFRIGERANT CHARGE R404A 1 lb. 14 oz. (850 g) WEIGHT Net 61 lbs. (28 kg) Shipping 68 lbs. (31 kg) CONNECTIONS REFRIGERANT One Shot Couplings (Aeroquip) ELECTRICAL Permanent Connection CONDENSER Air-coo[...]
-
Page 15
15 II. GENERAL INFORMA TION 1. CONSTRUCTION F-1000MAF/-C Water Supply Inlet Junction Box Condenser Fan Motor Compressor Drier Control Water Valve Bin Control Ice Chute Evaporator Expansion Valve Flush Water Valve Control Box Gear Motor[...]
-
Page 16
16 F-1000MWF/-C Water Supply Inlet Junction Box Water Regulator Compressor Drier Control Water Valve Bin Control Ice Chute Evaporator Expansion Valve Flush Water Valve Control Box Gear Motor[...]
-
Page 17
17 F-1000MRF/-C Water Supply Inlet Junction Box Compressor Receiver Tank Drier Control Water Valve Bin Control Ice Chute Evaporator Expansion Valve Flush Water Valve Control Box Gear Motor[...]
-
Page 18
18 Water Supply Inlet Junction Box Hot Gas Valve Solenoid Valve Heat Exchanger Control Water Valve Bin Control Ice Chute Evaporator Expansion Valve Flush Water Valve Control Box Gear Motor F-1000MLF/-C[...]
-
Page 19
19 2. CONTROL BOX LA YOUT F-1000MAF/-C Note: The above component names are identical with the Wiring Label, but not with the Parts List. PRESSURE SWITCH CONNECT OR ST ART CAP ACIT OR RUN CAP ACIT OR W A TER CONTROL RELA Y FLUSH TIMER TRANSFORMER GEAR M OTO R RELA Y GEAR M OTO R CAP . FLUSH ICE FA N M OTO R CAP GEAR MO TOR PRO TECT RELA Y ST ARTER C[...]
-
Page 20
20 F-1000MWF, F-1000MRF/-C PRESSURE SWITCH CONNECT OR ST ART CAP ACIT OR RUN CAP ACIT OR W A TER CONTROL RELA Y TRANSFORMER GEAR M OTOR RELA Y FLUSH ICE GEAR MO TOR PRO TECT RELA Y ST ARTER CONTROL TIMER FLUSH SWITCH PO WER SWITCH FUSE FUSE (GEAR MO TOR) FLUSH TIMER CIRCUIT PRO TECT RELA Y GEAR M OTOR CAP .[...]
-
Page 21
21 F-1000MLF/-C CONNECT OR W A TER CONTROL RELA Y TRANSFORMER FLUSH ICE GEAR MO TOR PRO TECT RELA Y CONTROL TIMER CIRCUIT PRO TECT RELA Y GEAR M OTO R CAP . FLUSH TIMER FLUSH SWITCH PO WER SWITCH FUSE FUSE (GEAR MO TOR)[...]
-
Page 22
22 III. TECHNICAL INFORMA TION 1. W A TER CIRCUIT AND REFRIGERA TION CIRCUIT F-1000MAF/-C[...]
-
Page 23
23 F-1000MWF/-C[...]
-
Page 24
24 F-1000MRF/-C[...]
-
Page 25
25 F-1000MLF/-C[...]
-
Page 26
26 2. WIRING DIAGRAMS F-1000MAF/-C, F-1000MWF/-C, F-1000MRF/-C[...]
-
Page 27
27 F-1000MLF/-C[...]
-
Page 28
28 3. SEQUENCE OF ELECTRICAL CIRCUIT [a] When Power Switch is moved to “ON” position and Flush Switch to “ICE” position, water starts to be supplied to Reservoir.[...]
-
Page 29
29 [b] When Reservoir has been filled, Gear Motor starts immediately.[...]
-
Page 30
30 [c] Compressor starts about 60 sec. after Gear Motor starts.[...]
-
Page 31
31 [d] Bin Control operates, and about 6 sec. later, Compressor and Gear Motor stop simultaneously.[...]
-
Page 32
32 [e] Low Water (Except Water-cooled Model).[...]
-
Page 33
33 [f] Low Water (Water-cooled Model), or Dirty Air Filter (Air-cooled Model), Pressure Switch to “OPEN”, Compressor and Gear Motor operates intermittently.[...]
-
Page 34
34 [g] When Flush Switch is moved to “FLUSH” position, Flush Water Valve opens and flushes Reservoir and Evaporator.[...]
-
Page 35
35 [h] When Flush Timer operates (for 15 min. every 12 hours).[...]
-
Page 36
36 [i] When 208-230V are supplied to Circuit Protect Relay, it protects the circuit from miswiring. If the power supply is properly connected, the contact of Circuit Protect Relay does not move even when the coil is energized.[...]
-
Page 37
37 [j] When input voltage is too low, (Less than 70%), Gear Motor Fuse (1.5A) is blown causing the Compressor and Gear Motor to turn off immediately.[...]
-
Page 38
38 Miswiring. Circuit Protect Relay operates.) Proper wiring. The unit starts. BIN CONTROL OFF ON 1. CIRCUIT PROTECT RELA Y 2. W A TER LEVEL 3. FLOA T SWITCH UPPER LOWER 4. W A TER CONTROL RELA Y 5. CONTROL WA TER VA LV E 6. FLUSH TIMER 7. FLUSH SWITCH 8. FLUSH W A TER VA LV E 9. BIN CONTROL 10. GEAR MOTOR RELA Y 1 1. GEAR MOTOR 12. F AN MOTOR 13. [...]
-
Page 39
39 1. CIRCUIT PROTECT RELA Y 2. W A TER LEVEL 3. FLOA T SWITCH UPPER LOWER 4. W A TER CONTROL RELA Y 5. CONTROL WA TER VA LV E 6. FLUSH TIMER 7. FLUSH SWITCH 8. FLUSH W A TER VA LV E 9. BIN CONTROL 10. GEAR MOTOR RELA Y 1 1. GEAR MOTOR 12. F AN MOTOR 14. PRESSURE SWITCH 15. HEA TER ON OFF ON OFF ON OFF ON OFF ON OFF 1 - 2 2 - 3 FLUSH ICE ON OFF ON [...]
-
Page 40
40 1. CIRCUIT PROTECT RELA Y 2. W A TER LEVEL 3. FLOA T SWITCH UPPER LOWER 4. W A TER CONTROL RELA Y 5. CONTROL WA TER VA LV E 6. FLUSH TIMER 7. FLUSH SWITCH 8. FLUSH W A TER VA LV E 9. BIN CONTROL 10. GEAR MOTOR RELA Y 1 1. GEAR MOTOR 12. F AN MOTOR 14. PRESSURE SWITCH 15. HEA TER ON OFF ON OFF ON OFF ON OFF ON OFF 1 - 2 2 - 3 FLUSH ICE ON OFF ON [...]
-
Page 41
41 5. PERFORMANCE DA T A F-1000MAF AP P RO XI M ATE Amb ien t W ate r Temp . (F ) ICE PRODUCTION T em p. (F) PER 24 HR. 70 9 70 (440) 930 (422) 890 (404) 80 855 (388) 820 (372) 785 (357) 90 755 (342) 740 (336) 695 (314) lbs./ day ( kg/ day ) 100 665 (301) 635 (289) 595 (270) APPROXIMATE E LECTRIC 70 1160 -- 1165 -- 1170 -- CONSUMPTION 80 1175 -- 11[...]
-
Page 42
42 F-1000MWF APP ROXI M ATE Ambien t W a te r Temp. (F) ICE PRODUCTION Tem p. (F) PER 24 HR. 70 8 90 ( 404) 855 (389) 840 (380) 80 820 (372) 805 (364) 785 (356) 90 770 (349) 755 (342) 735 (334) lbs./day (kg/day) 100 720 (327) 705 (320) 655 (297) APPROXIMATE ELECTRIC 70 1155 -- 1160 - - 1185 -- CONSUMPTION 80 1155 - - 1160 -- 1185 -- 90 1155 -- 1160[...]
-
Page 43
43 F-1000MRF APPROXIMATE Am bient W ater Tem p. (F) ICE PRODUCTI ON Tem p. (F) PER 24 HR. 70 930 (422) 895 (407) 865 (393) 80 835 (379) 80 5 (366) 780 (353) 90 750 (341) 74 5 (338) 700 (317) lbs./da y (kg/day ) 100 675 (306) 650 (296) 605 (274) APPROXIMATE ELECTRIC 70 1285 -- 1285 -- 12 90 -- CONSUMPT ION 80 1290 -- 1290 -- 1290 -- 90 1295 -- 1295 [...]
-
Page 44
44 F-1000MLF We reserve the right to make changes in specifications and design without prior notice. APP ROXIM ATE Ambien t W ater Temp. (°F) ICE PRODUCTION Tem p. (°F) PER 24 HR. 70 1150 (522) 1035 (469) 1005 ( 456) 80 980 (444) 950 (431) 925 (420) 90 900 (408) 885 (401) 850 (386) lbs./day (kg/day) 100 830 (376) 805 (366) 690 ( 313) APPRO X IMAT[...]
-
Page 45
45 F-1000MAF-C AP P ROXIM ATE Ambie nt W a te r Temp . (F ) ICE PRODUCTION T em p. (F) PER 24 HR. 70 8 60 (390) 820 ( 373) 790 (359) 80 765 (346) 735 (333) 710 (321) 90 680 (309) 665 (302) 635 (287) lbs./day (kg/ day ) 100 610 (277) 585 (266) 550 (249) APPROXIMATE ELE CT RIC 70 1210 -- 1215 -- 12 15 -- CONSUMPTION 80 1220 - - 1220 -- 1225 -- 90 122[...]
-
Page 46
46 F-1000MWF-C APP R OXIM ATE Ambie n t W ater Temp. (F) ICE PRODUCTION Tem p. (F) PER 24 HR. 70 7 90 ( 358) 760 (346) 750 (340) 80 735 (333) 720 (327) 710 (322) 90 695 (316) 685 (311) 670 (304) lbs./day (kg/day) 100 660 (299) 645 (294) 600 ( 272) APPROXIMATE ELECTRIC 70 1160 -- 1170 - - 1185 -- CONSUMPTION 80 1160 - - 1170 -- 1185 -- 90 1160 -- 11[...]
-
Page 47
47 F-1000MRF-C APP ROXIMATE Ambie nt W ater Temp. (F) ICE PRODUCTION Tem p. (F) PER 24 HR. 70 8 40 (381) 810 (368) 790 (358) 80 765 (347) 745 (337) 720 (327) 90 700 (317) 695 (315) 660 (299) lbs./day (kg/ day ) 100 640 (290) 620 (282) 575 ( 261) APPROXIMATE ELE CT RIC 70 1300 -- 1300 -- 1305 -- CONSUMPTION 80 1305 - - 1505 -- 1305 -- 90 1310 -- 131[...]
-
Page 48
48 F-1000MLF-C We reserve the right to make changes in specifications and design without prior notice. APP ROXIM ATE Ambien t W ater Temp. (°F) ICE PRODUCTION Tem p. (°F) PER 24 HR. 70 1020 (463) 945 (428) 915 (415) 80 885 (402) 860 (390) 835 (378) 90 805 (366) 795 (361) 760 (344) lbs./day (kg/day) 100 735 (333) 710 (323) 640 ( 290) APPRO X IMAT [...]
-
Page 49
49 IV . ADJUSTMENT OF COMPONENTS 1. ADJUSTMENT OF W A TER REGULA TING V AL VE - W A TER-COOLED MODEL ONL Y The Water Regulating Valve also called “WATER REGULATOR” is factory-adjusted. No adjustment is required under normal use. Adjust the Water Regulator , if necessary, using the following procedures. 1) Attach a pressure gauge to the high-sid[...]
-
Page 50
50 V . SERVICE DIAGNOSIS 1. NO ICE PRODUCTION PROBLEM POSSIBLE CAUSE REMEDY [1] The icemaker will not start. a) Power Supply 1. OFF position. 1. Move to ON position. 2. Loose connection. 2. Tighten. 3. Bad contacts. 3. Check for continuity and replace. 4. Blown fuse. 4. Replace. b) Power Switch (Control Box) 1. Off position. 1. Move to ON position.[...]
-
Page 51
51 PROBLEM POSSIBLE CAUSE REMEDY [4] Water has been supplied, Fan Motor starts, but Gear Motor and Compressor will not start. a) Gear Motor Fuse (BUSSMAN GMD 1.5A) 1. Blown Fuse. 1. See "3. [3]." Find out the cause and replace the Fuse. b) Thermal Protector (Gear Motor) 1. Bad contacts. 1. Check for continuity and replace. [5] Gear Motor [...]
-
Page 52
52 2. LOW ICE PRODUCTION PROBLEM POSSIBLE CAUSE REMEDY [1] Low ice production a) Refrigerant Line 1. Gas leaks. 1. See "1. [5] a) Refrigerant Line." 2. Refrigerant line clogged. 2. Replace the clogged component. 3. Overcharged. 3. Recharge. b) High-side Pressure Too High 1. Dirty Air Filter or Condenser. 1. Clean. 2. Ambient or condenser [...]
-
Page 53
53 3. OTHERS PROBLEM POSSIBLE CAUSE REMEDY [1] Abnormal noise a) Fan Motor 1. Bearing worn out. 1. Replace. 2. Fan blade deformed. 2. Replace fan blade. 3. Fan blade does not move freely. 3. Replace. b) Compressor 1. Bearings worn out, or cylinder valve broken. 1. Replace. 2. Mounting pad out of position. 2. Reinstall. c) Refrigerant Lines 1. Rub o[...]
-
Page 54
54 VI. REMOV AL AND REPLACEMENT OF COMPONENTS 1. SERVICE FOR REFRIGERANT LINES [a] REFRIGERANT RECOVERY [EXCEPT F-1000MLF(-C)] The icemaker unit is provided with two Refrigerant Access Valves - one on the low-side and one on the high-side line. Using proper refrigerant practices recover the refrigerant from the Access Valves and store it in an appr[...]
-
Page 55
55 2) Turn on the Vacuum Pump. Never allow the oil in the Vacuum Pump to flow backward. 3) Allow the Vacuum Pump to pull down to a 29.9" Hg vacuum. Evacuating period de- pends on pump capacity. 4) Close the Low-side Valve and High-side Valve on the Service Manifold. 5) Disconnect the Vacuum Pump, and attach a Refrigerant Service Cylinder to th[...]
-
Page 56
56 3. REMOV AL AND REPLACEMENT OF COMPRESSOR IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repairs or replacement have been made. 1) Turn off the power supply, and remove the panels. 2) Remove the Terminal Cover on the Compressor, and disconnect the Compres[...]
-
Page 57
57 14) Evacuate the system, and charge it with refrigerant. For the air-cooled and water-cooled models, see the Nameplate for the required refrigerant charge and type. For the remote air-cooled models, see the label on the Control Box. 15) Connect the Terminals to the Compressor, and replace the Terminal Cover in its correct position. 16) Replace t[...]
-
Page 58
58 5. REMOV AL AND REPLACEMENT OF EXP ANSION V AL VE IMPORT ANT Sometimes moisture in the refrigerant circuit exceeds the Drier capacity and freezes up at the Expansion Valve. Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repairs or replacement have been made. 1) Turn[...]
-
Page 59
59 6. REMOV AL AND REPLACEMENT OF W A TER REGULA TING V AL VE - W A TER-COOLED MODEL ONL Y IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repairs or replacement have been made. 1) Turn off the power supply, remove the panels and close the Water Supply Line S[...]
-
Page 60
60 7. REMOV AL AND REPLACEMENT OF CONDENSING PRESSURE REGULA TOR (C.P .R.) - REMOTE AIR-COOLED MODEL ONL Y IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repairs or replacement have been made. 1) Turn off the power supply. 2) Remove the panels from the remot[...]
-
Page 61
61 8. REMOV AL AND REPLACEMENT OF EV APORA TOR ASSEMBL Y 1) Turn off the power supply. 2) Remove the panels. 3) Move the Flush Switch to the "FLUSH" position. 4) Turn on the power supply and drain out all water from the water line. 5) Turn off the power supply. 6) Remove the Band connecting the Spout with the Chute Assembly. 7) Remove the[...]
-
Page 62
62 13) Recover the refrigerant and store it in an approved container, if required by an applicable law. IMPORT ANT Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repairs or replacement have been made. 14) Remove the Bulb of the Expansion Valve. 15) Disconnect the brazi[...]
-
Page 63
63 25) Remove the three Socket Head Cap Screws securing the Gear Motor. 26) Assemble the removed parts in the reverse order of the above procedure. W ARNING Be careful not to scratch the surface of the O-ring, or it may cause water leaks. Handle the Mechanical Seal with care not to scratch nor to contaminate its contact surface. 27) When replacing [...]
-
Page 64
64 Auger Mechanical Seal O-ring Bearing - Lower Bolt Washer Coupling - Spline Rubber O-ring Nylon Ring Bolt Washer Cutter Extruding Head Washer Socket Head Cap Screw Evaporator Washer Socket Head Cap Screw Barrier Gear Motor[...]
-
Page 65
65 9. REMOV AL AND REPLACEMENT OF F AN MOTO R 1) Turn off the power supply and remove the panels. 2) Remove the wire connectors from the Fan Motor leads. 3) Remove the Fan Motor Bracket and Fan Motor. 4) Install the new Fan Motor. 5) Replace the Fan Motor Bracket and the wire connectors. 6) Replace the panels in their correct position, and turn on [...]
-
Page 66
66 1 1. REMOV AL AND REPLACEMENT OF FLUSH W A TER V AL VE 1) Turn off the power supply, remove the panels and close the Water Supply Line Shut- off Valve. 2) Remove the Clamp and disconnect the Hose from the Flush Water Valve. Note: Water may still remain inside the Evaporator. Be sure to drain the water into the Drain Pan. 3) Disconnect the Termin[...]
-
Page 67
67 VII. MAINTENANCE AND CLEANING INSTRUCTIONS IMPORT ANT Ensure all components, fasteners and thumbscrews are securely in place after any maintenance or cleaning is done to the equipment. 1. PREP ARING THE ICEMAKER FOR LONG STORAGE W ARNING When shutting off the icemaker for an extended time, drain out all water from the water line and remove the i[...]
-
Page 68
68 [Water-cooled Models] 1) Turn off the power supply and wait for 3 minutes. 2) Turn on the power supply and wait for 20 seconds. 3) Close the Water Supply Line Shut-off Valve. 4) Open the Drain Valve and quickly blow the water supply line from the Drain Valve to drain water in the Condenser. 5) Follow the above steps 3) through 11) in [Air-cooled[...]
-
Page 69
69 2. CLEANING INSTRUCTIONS IMPORT ANT Ensure all components, fasteners and thumbscrews are securely in place after any maintenance or cleaning is done to the equipment. W ARNING 1. HOSHIZAKI recommends cleaning this unit at least once a year. More frequent cleaning, however, may be required in some existing water conditions. 2. To prevent injury t[...]
-
Page 70
70 6) Turn on the power supply and drain out all water from the water line. 7) Turn off the power supply. 8) Remove the Control Water Valve by releasing the Fitting Nut. Do not lose the Packing. 9) Remove the Cover of the Reservoir. 10) Fill the Reservoir with the cleaning solution. 11) Replace the Cover of the Reservoir and the Control Water Valve[...]
-
Page 71
71 5) Replace the Cover of the Reservoir and the Control Water Valve in their correct position. 6) Move the Flush Switch to the “ICE” position. 7) Replace the Top Panel and the Front Panel in their correct position. 8) Allow the icemaker to set for about 10 minutes before the operation. Then, turn on the power supply, and make ice using the sol[...]
-
Page 72
72 6) Remove the two Thumbscrews, Plate, and Gasket at the top of the Ice Chute, and then remove the Bin Control Assembly by sliding it slightly toward the Spout and lifting it off. 7) Disassemble the Bin Control Assembly by removing the two Snap Pins, Shaft and Activator. 8) Remove the three Thumbscrews and the Spout. 9) Remove the Rubber O-ring a[...]
-
Page 73
73 3. MAINTENANCE IMPORT ANT 1. This icemaker must be maintained individually, referring to the instruction manual and labels provided with the icemaker. 2. To have the optimum performance of this icemaker, the following consumable parts need periodic inspection, maintenance and replacement: Extruding Head Housing Gear Motor Auger Mechanical Seal T[...]
-
Page 74
74 3) Air Filter (Air-cooled model only) A plastic mesh air filter removes dirt or dust from the air, and keeps the Condenser from getting clogged. As the filter gets clogged, the icemaker’s performance will be reduced. Check the filter at least twice a month. When clogged, use warm water and a neutral cleaner to wash the filter. 4) Condenser (Ex[...]