HP (Hewlett-Packard) 230859-004 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of HP (Hewlett-Packard) 230859-004, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of HP (Hewlett-Packard) 230859-004 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of HP (Hewlett-Packard) 230859-004. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of HP (Hewlett-Packard) 230859-004 should contain:
- informations concerning technical data of HP (Hewlett-Packard) 230859-004
- name of the manufacturer and a year of construction of the HP (Hewlett-Packard) 230859-004 item
- rules of operation, control and maintenance of the HP (Hewlett-Packard) 230859-004 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of HP (Hewlett-Packard) 230859-004 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of HP (Hewlett-Packard) 230859-004, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the HP (Hewlett-Packard) service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of HP (Hewlett-Packard) 230859-004.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the HP (Hewlett-Packard) 230859-004 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    HP ProLiant BL p-Class System Diagnostic Station User Guide Part Number 230859-004 April 2004 (Fourth Edition)[...]

  • Page 2

    © Copyright 2002, 2004 Hewlett-Packard Development Company, L.P. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. Intel and Pentium are trademarks or register ed trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Java is a US registered tradem ark of Sun Microsystems, Inc. He[...]

  • Page 3

    Contents Abstr act .......................................................................................................... 5 Diagnostic Station Kit Cont ents................................................................... 6 Warnings and C autions ................................................................................ 7 Using the Diag[...]

  • Page 4

    BSMI Notice .................................................................................................................... .3 4 4 HP ProLiant BL p-Class System Diag nostic Station User Guide[...]

  • Page 5

    Abstract This document provides instructions fo r cabling the diagnostic station to an HP ProLiant BL p-Class server blade to enable out-of-rack communication with the server blade. HP ProLiant BL p-Class System Diagnostic Station User G uide 5[...]

  • Page 6

    Diagnostic Station Kit Contents NOTE: You may need additional items, dependin g on the server blade you are using. Figure 1: Diagnostic station kit contents Table 1: Diagnostic Station Kit Contents Item Description 1 Diagnostic station 2 VHDM converter 3 Data transfer cable continued 6 HP ProLiant BL p-Class System Diag nostic Station User Guide[...]

  • Page 7

    Table 1: Diagnostic Station Kit Contents continued Item Description 4 DC power cord (for server blade) 1 5 DC power cord (for interconnect switch) 6 AC power cord 2 7 Network cable with RJ-45 connectors Not shown Documentation CD-ROM Not shown This installation guide 1 For information about connecting the diag nostic station to an interconnect swit[...]

  • Page 8

    CAUTION: Properly ground yourself before begi nning any installation procedur e. Electrostatic discharge can damage elec tronic components. For more information about electrostatic discharge, refer to the setup and instal lation guide. CAUTION: Disconnect the local I/O cable when not in use. The port and connector do not provide a permanent c onnec[...]

  • Page 9

    Identifying Diagnostic and Lo cal I/O Cable Connectors Use Figure 3 and Table 2 to identify diagnos tic cable and local I/O cable connectors. Figure 3: Diagnostic cable (top) and local I/O cable (bottom) connectors Table 2: Diagnostic and Local I/O Cable Connectors Item Connector Name Connector Description Diagnostic cable (top) 1 Server blade conn[...]

  • Page 10

    Table 2: Diagnostic and Local I/O Cable Connectors continued Item Connector Name Connector Description 3 Kernel debug connector 2 Requires a null modem serial cable and enables trained personnel to perform advanced diagnostic procedur es. Local I/O cable (bottom) 3 4 Video connector Provides vide o capability. 5 USB connector 1 Provides USB connect[...]

  • Page 11

    Installing the Diagnostic Ca ble or the Local I/O Cable To install the diagnostic cable or the local I/O cable with the diagnostic station, see the “Diagnostic Station” section. To install the diagnostic cable on a server blade in the rack, refer to the setup and installation guide included with the server blade. Diagnostic Station The diagnost[...]

  • Page 12

    For more information about installi ng hardware options and performing troubleshooting procedures, refer to the p-Cl ass server blade setup and installation guides on the Documentation CD and to the documentation that ships with the interconnect switch. Diagnostic Station Components Use Figure 4 and Table 3 to identif y diagnostic station component[...]

  • Page 13

    Table 3: Diagnostic Station Components continued Item Component Description 5 Reserved for ad ditional AC p ower 6 AC power input connector 7 DC power output connectors 8 Data transfer port 9 NIC LEDs 10 Power On/Off button 11 Power and health LED * This component does not apply to the ProLiant BL30 p server blade. Accessing the Cable Storage Area [...]

  • Page 14

    Client PC Requirements Observe the following minimum software and hardware requirements for a client PC: • Intel® Pentium® III or higher processor (700 MHz or greater recommended) • 128 MB of RAM • Microsoft® Windows® 2000 Professional or Microsoft Windows XP operating system • Microsoft Internet Explorer 5.5 or above with 128-bit encry[...]

  • Page 15

    Preparing the Server Blade for Connection Before connecting the diagnostic station to a server blade: 1. Power down the server blade. 2. Remove the server blade from the se rver blade enclosure in the rack. IMPORTANT: If the server blade is a ProLiant BL30p, install the server blade into a bla de sleeve and connect the blade sleeve to a diagnostic [...]

  • Page 16

    — With USB devices—Connect the local I/O cable to the I/O port on the front of the server blade. This connection enables you to connect a monitor through the video connector and various USB devices, such as a USB keyboard, USB mouse, USB floppy, and/or a USB CD-ROM, directly to the server. NOTE: Use of the USB hub is optional as the hub is only[...]

  • Page 17

    To connect a client PC to the server using the direct cabling method: 1. Thread the DC power cord for a server blade or blade sleeve through the opening in the VHDM converter (1). 2. Snap the cord into place in the VHDM converter (2). Figure 6: Threading the DC power co rd through the VHDM converter HP ProLiant BL p-Class System Diagnostic Station [...]

  • Page 18

    3. Place the VHDM converter on the rear of th e server blade or the blade sleeve by inserting the tab into the right side (1), making sure the pins on t he left side are properly aligned. 4. Tighten the thumbscrew to secure the VHDM converter to the server blade (2) or the blade sleeve. 5. Insert the DC power cord into one of the diagnostic station[...]

  • Page 19

    6. Connect the data transfer cable to the VHDM converter on the server blade (1) or the blade sleeve. 7. Connect the other end of the data transf er cable to the diagnostic station (2). Figure 8: Connecting the data transfer cable HP ProLiant BL p-Class System Diagnostic Station User G uide 19[...]

  • Page 20

    8. Connect the server blade to the client PC using the diagnostic cable. If you are using the local I/O cable to connect to the I/O port, go to step 9. CAUTION: Disconnect the diagnostic cable when not in use. The port and connector do not provide a permanent conne ction. Rear iLO connector performance degrades when the local I/O cable is in use, e[...]

  • Page 21

    9. Connect the server blade to a clie nt PC using the local I/O cable. CAUTION: Disconnect the local I/O cable when not in use. The port and connector do not provide a permanent conne ction. Rear iLO connector performance degrades when the local I/O cable is in use, even when the iLO connector on the cable is not in use. a. Connect the network cabl[...]

  • Page 22

    IMPORTANT: If you are connecting to a ProLiant BL30p server blade, the server blade must be installed in the left slot of t he blade sleeve on a flat surfac e. Figure 11: Connecting the Pr oLiant BL30p server blade to a client PC using the local I/O cable 22 HP ProLiant BL p-Class System Diagnostic Station User G uide[...]

  • Page 23

    IMPORTANT: The diagnostic station ships with seve ral AC power c ords of different outlet plug configurations. Be sure to select the pro per AC power cord for the ele ctrical service. 10. Connect the AC power cord to the diagnostic station (1). 11. Connect the other end of the AC power cord to an AC outlet (2). NOTE: Previously installed components[...]

  • Page 24

    Refer to Figure 13 for the completed dir ect cabling method using diagnostic cable (left) and the local I/O cable (right). Figure 13: Completed direct cabling method (front and rear views) using the diagnos tic cable (1) and the local I/O cable (2) to connect to iLO After the direct cabling method is complete, the server blade and diagnostic statio[...]

  • Page 25

    CAUTION: Disconnect the local I/O cable when not in use. The port and connector do not provide a permanent conne ction. Rear iLO connector performance degrades when the local I/O cable is in use, even when the iLO connector on the cable is not in use. 3. Connect the monitor to the video connector on the local I/O cable. 4. Connect a USB hub to the [...]

  • Page 26

    Refer to Figure 14 for the completed dir ect cabling method using USB devices and the local I/O cable. Figure 14: Completed direct cabling method (front and rear view) using the local I/O cable and USB devices to directly access the serve r blade After the direct cabling method is complete, the server blade and diagnostic station are ready for use.[...]

  • Page 27

    IMPORTANT: The DHCP server assigns the IP address to the iLO NIC. The DHCP server is not necessary if you have configur ed iLO and/or any other connected NICs to use a static IP address. To connect with the network cabling method: 1. Follow steps 1 through 7 of “Using the Direct Cabling Method with a Client PC” to make the connections from the [...]

  • Page 28

    IMPORTANT: If you are using the diagnostic station for operatin g system deployment or file management, connect an additi onal network cable with RJ-45 connectors betwe en the NIC 1 connector and the hub. 4. Connect an additional network cable with RJ-45 connectors between the client PC (1) and the hub (2). Figure 16: Connecting a networ k cable to[...]

  • Page 29

    Figure 17 shows a completed network cabling method with the DHCP server (1) and the hub (2). IMPORTANT: For operating system deployment or f ile management, an optio nal server can be connected to the hub. NOTE: Connecting the diagnostic cable to t he diagnostic port or connecting the loc al I/O cable to the I/O port automatically disables the iLO [...]

  • Page 30

    3. Power up the client PC in accordance with its own documentation. NOTE: iLO may take up to 90 seconds to establish a secure network connection. IMPORTANT: If tasks are to be performed on more than one ProLiant BL30p server blade, power down the first server blade and remove it from the blade sleeve. Th en, instal l the next server blade in the le[...]

  • Page 31

    Network Cabling Method In this method, the client PC is connect ed to the iLO using a hub/switch and the network connections of the diagnostic station. The iLO default configuration enables the server blade to obtain its IP address from a DHCP server. NOTE: If you have edited the configuration to us e a static IP address, iLO uses this same static [...]

  • Page 32

    GbE Interconnect Switch You can configure or troubleshoot a GbE interconnect switch in an out-of-rack environment. In this situation, the di agnostic station provides power to the interconnect switch. Use the following items from the diagnostic station kit: • Diagnostic station • DC power cord (for interconnect switch) • Network cable with RJ[...]

  • Page 33

    Modifications The FCC requires the user to be notified th at any changes or modifications made to this device that are not expressly appr oved by Hewlett-Packard Company may void the user's authority to operate the equipment. Cables Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to m[...]

  • Page 34

    34 HP ProLiant BL p-Class System Diagnostic Station User G uide • EN61000-3-3 (IEC61000-3-3) – Power L ine Flicker • EN 60950 (IEC 60950) – Product Safety Japanese Notice Korean Notice BSMI Notice[...]