Go to page of
Similar user manuals
-
Network Router
HP (Hewlett-Packard) e1200-160
200 pages 3.96 mb -
Network Router
HP (Hewlett-Packard) HP 37722A
8 pages 0.17 mb -
Network Router
HP (Hewlett-Packard) 6100
50 pages 1.41 mb -
Network Router
HP (Hewlett-Packard) 3400cl
4 pages 0.21 mb -
Network Router
HP (Hewlett-Packard) MSA50
9 pages 0.08 mb -
Network Router
HP (Hewlett-Packard) DT-50
20 pages 0.07 mb -
Network Router
HP (Hewlett-Packard) IEEE 1394
80 pages 2.73 mb -
Network Router
HP (Hewlett-Packard) SL500 (M852x)
76 pages 2.74 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of HP (Hewlett-Packard) 359449-001, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of HP (Hewlett-Packard) 359449-001 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of HP (Hewlett-Packard) 359449-001. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of HP (Hewlett-Packard) 359449-001 should contain:
- informations concerning technical data of HP (Hewlett-Packard) 359449-001
- name of the manufacturer and a year of construction of the HP (Hewlett-Packard) 359449-001 item
- rules of operation, control and maintenance of the HP (Hewlett-Packard) 359449-001 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of HP (Hewlett-Packard) 359449-001 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of HP (Hewlett-Packard) 359449-001, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the HP (Hewlett-Packard) service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of HP (Hewlett-Packard) 359449-001.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the HP (Hewlett-Packard) 359449-001 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
March 2004 Part Number 359449-001 HP High Performance Clusters LC 1000 Series Design and Configuration Guide 359449-001 1[...]
-
Page 2
Table Of Contents Introduction 3 - 4 23 22 17- 21 16 11 - 15 Myrinet Order Worksheet 10 Myrinet Reference Desi gns 6 - 9 GigE Order Worksheet GigE Reference Designs Fast Ethernet Order Worksheet Fast Ethernet Reference Designs DL380 and DL140 Options Myrinet Upgrade Worksheet Fast Ethernet Up grade Worksheet GigE Upgrade Worksheet Storage Subsystem[...]
-
Page 3
Introduction Summ ary: The LC 1000 Series Design and Configuration Guide provide s an easy and flexible way to design High Performance Computing (HPC) clusters. I t is easy to design an HPC cluste r with this guide bec ause ever ything needed for the cl us ter is speci fied through R eference Desi gns. The flexible proce ss provides the ability to [...]
-
Page 4
Softwar e Options: Software options such as operating s ystem media and licenses are availabl e. Pl ease refer to the LC 1000 Serie s Software Options worksheet fo r part numbers and quantities. T he operating system options avail able with th e LC 1000 Series Clusters include Red Ha t 3 one year and three year licenses, SLES 8 one year and thre e [...]
-
Page 5
LC 1000 Series Design and Configuration Matrix Cluster Interconnect Net w or k # of Compute Nodes Ma xi mu m Future Expa nsio n Reference Design Refe renc e Parts List Pages 1 - 32 32 16 Node M y rinet 1 - 32 Nodes 6 1 - 32 Nodes 7 33 - 64 Nodes 7 29 - 68 Nodes 8 - 9 69 - 108 Nodes 8 - 9 109 - 128 Nodes 8 - 9 1 - 22 22 16 Node Gi g E 1 - 22 Nodes 1[...]
-
Page 6
Myrinet (expandable to 32 nodes) iLO NIC2 NIC1 Serial DL380 Control Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node SW3 Cyclades (OOB Management Switch) SW1 Myricom w/Myrin et Line Cards (Cluster Interconnec t Switch) SCSI 2 SCSI 1 Public LAN Optional Storage Solution Rack 1 Myr Myr SW2 ProCurve [...]
-
Page 7
Myrinet (expandable to 64 nodes) LC 1000 Series 32 Node Myrinet DL140 Cluster Reference Design iLO NIC2 NIC1 Serial DL380 Control Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node SW2 ProCurve 2848 10/100/1000 (IB Management Switch) SW3 Cyclades (OOB Management Switch) SW1 Myricom w/Myrin et Line C[...]
-
Page 8
Myrinet (expandable to 128 nodes) LC 1000 Series 64 Node Myrinet DL140 Cluster Reference Design iLO NIC2 NIC1 Serial DL380 Control Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node SW2 ProCurve 2848 10/100/1000 (IB Management Switch) SW3 Cyclades (OOB Management Switch) SW1 Myricom w/ Myrinet Line [...]
-
Page 9
LC 1000 Series 64 Node Myrinet DL140 Cluster Reference Design W W W XX X YY Y ZZZ US ABA 001 001 D72 EMEA ABB 42 1 B31 B31 Part Number Ke y Notes: 1. # represents the number of compute nodes. 2. Please refer to the server options table for a dding processors, memory, disks, networ k adapters, ... Part Numbers LC 1000 Series Pa rts List M y rinet 29[...]
-
Page 10
LC 1000 Series Myrinet DL 140 Cluster Order Worksheet Note: Please make multiple copies for future use. W W W XXX YYY ZZZ US AB A 001 001 D72 EM EA ABB 421 B31 B31 Part Numb er Key Part Num ber s LC 1000 S eries Parts List M y rinet Order Factor y Inte g ration Quant it y 325733-888 Level 4 Factor y Inte g ration 359578-B21 C onfi g uration Re sour[...]
-
Page 11
iLO NIC2 NIC1 Serial DL380 Control Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node SW1 ProCurve 2848 10/100/1000 (IB Management Switch) SW2 Cyclades (OOB Management Switch) SCSI 2 SCSI 1 Public LAN Optional Storage Solution Rack 1 GigE (expandable to 22 nodes) LC 1000 Series 16 Node GigE DL140 Cl[...]
-
Page 12
GigE (expandable to 36 nodes) LC 1000 Series 24 Node GigE DL140 Cluster Reference Design iLO NIC2 NIC1 Serial DL380 Control Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node SW2 ProCurve 2848 10/100/1000 (IB Management Switch) SW3 Cyclades (OOB Management Switch) SCSI 2 SCSI 1 Public LAN Rack 1 SW1[...]
-
Page 13
GigE (expandable to 64 nodes) LC 1000 Series 32 Node GigE DL140 Cluster Reference Design iLO NIC2 NIC1 Serial DL380 Control Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node SW2 ProCurve 2848 10/100/1000 (IB Management Switch) SW3 Cyclades (OOB Management Switch) SW1 Myricom w/GigE Line Cards (Clus[...]
-
Page 14
GigE (expandable to 128 nodes) LC 1000 Series 64 Node GigE DL140 Cluster Reference Design iLO NIC2 NIC1 Serial DL380 Control Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node SW2 ProCurve 2848 10/100/1000 (IB Management Switch) SW3 Cyclades (OOB Management Switch) SW1 Myricom w/GigE Line Cards (Clu[...]
-
Page 15
LC 1000 Series 64 Node GigE DL140 Cluster Reference Design W W W XXX YYY ZZZ US ABA 001 001 D72 EM EA ABB 421 B31 B31 Part Numbe r Key Notes: 1. # represents the number of compute nodes. 2. Please refer to the server options table for a dding processors, memory, disks, networ k adapters, ... Part Num bers LC 1000 Series Par ts List Gi g E 29 - 68 N[...]
-
Page 16
LC 1000 Series GigE DL14 0 Cluster Order Worksheet Note: Please make multiple copies for future use. W W W XX X YY Y ZZZ US ABA 001 001 D72 EMEA ABB 42 1 B31 B31 Par t Numb er K ey Part Num ber s LC 1000 S eries Parts List Gi g E Orde r Factor y Inte g ration Quant it y 325733-888 Level 4 Factor y Inte g ration 359578-B21 C onfi g uration Re source[...]
-
Page 17
Fast Ethernet (expandable to 22 nodes) iLO NIC2 NIC1 Serial DL380 Control Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node SW1 ProCurve 2650 10/100 (IB Management Switch) SW2 Cyclades (OOB Management Switch) SCSI 2 SCSI 1 Public LAN Optional Storage Solution Rack 1 LC 1000 Series 16 Node Fast Ethe[...]
-
Page 18
Fast Ethernet (expandable to 36 nodes) iLO NIC2 NIC1 Serial DL380 Control Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node SW2 ProCurve 2650 10/100 (IB Management Switch) SW3 Cyclades (OOB Management Switch) SCSI 2 SCSI 1 Public LAN Rack 1 SW1 ProCurve 2650 10/100 (Cluster Interconnect Switch) Opt[...]
-
Page 19
Fast Ethernet (expandable to 72 nodes) LC 1000 Series 32 Node Fast Ethe rnet DL140 Cluster Reference Design iLO NIC2 NIC1 Serial DL380 Control Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node SW2 ProCurve 2650 10/100 (IB Management Switch) SW3 Cyclades (OOB Management Switch) SW1 ProCurve 5372 10/[...]
-
Page 20
iLO NIC2 NIC1 Serial DL380 Control Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Compute Node SW2 ProCurve 2848 10/100/1000 (IB Management Switch) SW3 Cyclades (OOB Management Switch) SW1 ProCurve 5372 10/100 (Cluster Interconnect Switch) SCSI 2 SCSI 1 Public LAN Rack 2 NIC1 ATA 2 NIC2 Serial ATA 1 DL140 Co[...]
-
Page 21
LC 1000 Series 64 Node Fast Ethe rnet DL140 Cluster Reference Design W W W XXX YYY ZZZ US ABA 001 001 D72 EM EA ABB 421 B31 B31 Part Numbe r Key Notes: 1. # represents the number of compute nodes. 2. Please refer to the server options table for a dding processors, memory, disks, networ k adapters, ... Par t Nu mb er s L C 1000 Series Parts List Fas[...]
-
Page 22
LC 1000 Series Fast Ethernet DL140 Cluster Order Worksheet Note: Please make multiple copies for future use. W W W XX X YY Y ZZZ US ABA 001 001 D72 EMEA ABB 42 1 B31 B31 Par t Numb er K ey Part Num ber s LC 1000 Series Parts Li st Fas t Ethern et Orde r Factor y Inte g ration Quant it y 325733-888 Level 4 Factor y Inte g ration 359578-B21 C onfi g [...]
-
Page 23
LC 1000 Series DL380 and DL140 Options Note: Please make multiple copies for future use. Part Numbers LC 1000 Series Parts List O p tions Order DL380G3 Con trol Node Quantit y 293048-B 21 Fan Kit 313054-B 21 Hot Plug Redundant P ower Supply 333714-B 21 1P-3.2GHz 1MB Cache 533M Hz FSB Pr ocessor O p tion Kit 333713-B 21 1P-3.06GHz 1M B Cach e 533M H[...]
-
Page 24
LC 1000 Series Software Options Note: 1. # represents the number of co mpute nodes. 2. Please make multiple copies for future use. Note: Scali Manage/Connect is support ed o n Linux operating systems only. Scali Control Comp ute Quantity 359960-B21 Scali Manage/Connect for TCP/IP, M edia and Contol Node Licens e 359962-B21 Scali Manage/Connect for [...]
-
Page 25
LC 1000 Series Fibre Chan nel GFS (16 node - 48 TB) Note: Please refer to the storage subsystem opt ions table for adding processors, memory, disks, network adapters, rack and power , ... 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 25 24 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 26 23 DL380 Storage Node MSA30 2 TB DL380 Storage N[...]
-
Page 26
LC 1000 Series Fibre Channel GFS (8 node - 24 TB) 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 25 24 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 26 23 MSA1000 MSA1000 MSA1000 MSA30 2 TB MSA1000 2 TB DL380 Storage Node DL380 Storage Node DL380 Storage Node DL380 Storage Node DL380 Storage Node DL380 Storage Node DL380 Storage Node DL[...]
-
Page 27
DL380 Storage Node DL380 Storage Node 4 Storage Node s FC 2214 FC 2214 2 TB 2 TB MSA1000 2 TB 2 TB 2 TB LC 1000 Series Fibre Channel GFS (4 node - 12 TB) iLO NIC2 SCSI 2 NIC1 Serial SCSI 1 iLO NIC2 SCSI 2 NIC1 Serial SCSI 1 Storage Nodes MSA30 MSA30 MSA30 MSA30 ProCurve 2824 10/100/1000 Cluster Co nnection 1 MSA1000 w/Embedded SAN Switch 2/8 4 MSA3[...]
-
Page 28
ProCurve 5372 Myricom 5 slot chassi s w/Myrinet line cards MSA1000 DL380 Storag e Node DL380 Storag e Node MSA500 2 TB 8U LC 1000 Series SCSI High Availability NFS 2TB LC 1000 Series Fibre Channel GFS (2 node - 6 TB) WWW X X X US ABA 001 EMEA ABB 421 Part Number Key Cluster Co nnection DL380 Storage Node DL380 Storage Node MSA500 2 TB iLO NIC2 SCSI[...]
-
Page 29
4454 2 TB LC 1000 Series SCSI NFS 4TB LC 1000 Series SCSI NFS 8TB MSA30 2 TB 2 TB MSA30 2 TB DL380 Storage Node 8U MSA30 2 TB 2 TB MSA30 2 TB DL380 Storage Node 14U MSA30 2 TB MSA30 2 TB WWW X X X US ABA 001 EMEA ABB 421 Part Number Key DL380 Storage Node 36GB 6404 MSA30 2 TB MSA30 2 TB iLO NIC2 SCSI 2 NIC1 Serial SCSI 1 MSA30 2 TB MSA30 2 TB Stora[...]
-
Page 30
LC 1000 Series Storage Subsystem Options Note: Please make multiple copies for future use. YYY ZZ Z US 001 D72 EMEA B31 B31 Part Number Key Part Num ber s Storage Subs y stem O ptions Order DL380G3 Quantit y 263825-B21 iLO Advanced Pack ALL 293048-B21 Fan Kit 333714-B21 1P-3.2GHz 1M B Cache 533M Hz FSB Processor Option 333713-B21 1P-3.06GHz 1M B Ca[...]
-
Page 31
LC 1000 Series Myrinet DL14 0 Cluster Upgrade Worksheet Note: Please make multiple copies for future use. W W W XXX YYY ZZZ US ABA 0 01 001 D72 EM EA ABB 421 B31 B31 Part Number Key Part Nu mbe rs LC 1000 Ser ies Parts List M y rinet U pg rade Current Confi g uration New Confi g uration Parts Needed ( New Confi g - Current Confi g) DL380G 3 Cont ro[...]
-
Page 32
LC 1000 Series GigE DL1 40 Cluster Upgrade Worksheet Note: Please make multiple copies for future use. W W W XX X YY Y ZZZ US ABA 001 001 D72 EMEA ABB 42 1 B31 B31 Par t Numb er K ey Part Num bers LC 1000 Ser ies Parts List Gi g E U pg rade Current Confi g uration New Confi g uration Parts Needed ( New Confi g - Current Conf i g) DL380G3 Control No[...]
-
Page 33
LC 1000 Series Fast Ethernet DL140 Cluster Upgrade Worksheet Note: Please make multiple copies for future use. W W W XX X YY Y ZZZ US ABA 001 001 D72 EMEA ABB 42 1 B31 B31 Par t Numb er K ey Part N umb ers LC 1000 Seri es Parts List Fast Et hernet U pg rade Current Confi g uration New Confi g uration Parts Need ed ( New Confi g - Current Confi g) D[...]