Go to page of
Similar user manuals
-
Server
HP (Hewlett-Packard) AA-RTDRB-TE
146 pages 2.61 mb -
Server
HP (Hewlett-Packard) 686211-S01
57 pages 2.98 mb -
Server
HP (Hewlett-Packard) RP4410
288 pages 9.43 mb -
Server
HP (Hewlett-Packard) V2500
314 pages 1.21 mb -
Server
HP (Hewlett-Packard) L700 (CTL700)
154 pages 2.77 mb -
Server
HP (Hewlett-Packard) 642106-001
134 pages 5.91 mb -
Server
HP (Hewlett-Packard) QK765A
76 pages 2.4 mb -
Server
HP (Hewlett-Packard) ML310
123 pages 2.7 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of HP (Hewlett-Packard) BL685C G6, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of HP (Hewlett-Packard) BL685C G6 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of HP (Hewlett-Packard) BL685C G6. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of HP (Hewlett-Packard) BL685C G6 should contain:
- informations concerning technical data of HP (Hewlett-Packard) BL685C G6
- name of the manufacturer and a year of construction of the HP (Hewlett-Packard) BL685C G6 item
- rules of operation, control and maintenance of the HP (Hewlett-Packard) BL685C G6 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of HP (Hewlett-Packard) BL685C G6 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of HP (Hewlett-Packard) BL685C G6, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the HP (Hewlett-Packard) service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of HP (Hewlett-Packard) BL685C G6.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the HP (Hewlett-Packard) BL685C G6 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
HP Pr oL iant BL6 8 5c G6 Ser v er Blade Maintenance and S erv ice Gui de Part Number 508504-001 April 2009 (First Edition)[...]
-
Page 2
© Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice . The only warranties for HP products and services are set forth in the express warranty statements accompanying such produc ts and services. Noth ing herein should be construed as constituting an additional w arranty. HP[...]
-
Page 3
Contents 3 Con t en t s Customer self repair ........................................................................................................... ........... 5 Parts only warr anty service .................................................................................................... ..................... 5 Illustrated pa rts cata log .[...]
-
Page 4
Contents 4 HP Insight Remote Support so ftware ............................................................................................. .............. 54 USB support and functionality .................................................................................................. ................. 55 USB support .............................[...]
-
Page 5
Customer self repair 5 C ustome r sel f r e pa ir HP products are designed with many Customer Self Repair (CSR) parts to minimi ze repair time and allow for greater flexibility in performing defe ctive parts re placement. If during the di agnosis period HP (or HP service providers or service partners) iden tifies that the repair can be accomplished[...]
-
Page 6
Customer self repair 6 • Obligatoire - Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de remplacer ces pièces, les coûts de déplac ement et main d'œuvre du service vous seront facturés. • Facultatif - Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont é[...]
-
Page 7
Customer self repair 7 NOTA: alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la garanzia, HP richiede che queste parti siano sostitui te da un centro di assistenza autorizzato. Tali parti sono identificate da un "No" nel Catalogo illustrato dei componenti. In base alla disponibilità e alla[...]
-
Page 8
Customer self repair 8 anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materiali en, die mit einem CSR- Ersatzteil geliefert werden, könn en Sie entnehmen, ob das defekte Teil an HP zurückgesch ickt werden muss. Wenn es erforderlich ist, das defekte Teil an HP zurückzusch icken, müssen Sie dies innerhalb eines vorgegebenen[...]
-
Page 9
Customer self repair 9 Centro de asistencia técnica de HP y reci birá ayu da telefónica por parte de un técnico. Con el envío de materiales para la sustitución de componente s CSR, HP especificará si los comp onentes defectuosos deberán devolverse a HP. En aquellos casos en los que sea necesario devolver algún componente a HP, deberá hace[...]
-
Page 10
Customer self repair 10 periode, gewoonlijk vijf (5) werkdagen, retourneren aan HP. Het defecte onderdeel moet met de bijbehorende documentatie worden geretourneerd in het meegel everde verpakkingsmateriaal. Als u het defecte onderdeel niet t erugzendt, kan HP u voor het vervangende onderdeel kosten in rekening brengen. Bij reparatie door de klant [...]
-
Page 11
Customer self repair 11 Se r v iço de gar anti a ape nas par a peças A garantia limitada da HP pode incluir um serviço de garantia apenas para pe ças. Segundo os termos do serviço de garantia apenas para peças, a HP fo rnece as peças de reposição sem cobrar nenhuma taxa. No caso desse serviço, a substituição de peças CSR é obrigatóri[...]
-
Page 12
Customer self repair 12[...]
-
Page 13
Customer self repair 13[...]
-
Page 14
Customer self repair 14[...]
-
Page 15
Customer self repair 15[...]
-
Page 16
Illustrated parts catalog 16 Illus tr ated par ts catalog Server blade components Item Description Spare part number Customer self repair (on page 5 ) 1 Access panel 532159-001 Ma ndatory 1 2 Heatsink — — a) Processor 1 and 2 511658-001 Optional 2 b) Processor 3 and 4* 511659-001 Optional 2 3 Processor — — a) 2.9-GHz AMD Opteron™ Mode l 8[...]
-
Page 17
Illustrated parts catalog 17 Item Description Spare part number Customer self repair (on page 5 ) c) 4-GB, PC2-6400, RoHS* 501158-001 Mandatory 1 d) 4-GB, PC2-6400, LP* 504589-001 Mandatory 1 e) 8-GB, PC2-5300* 432671-001 Mandatory 1 7 Hard drives — — a) 300-GB, 6G, SAS, SFF, 10, 000-rpm, dual-port* 507284-001 Mandatory 1 b) 300-GB, 3G, SAS, SF[...]
-
Page 18
Illustrated parts catalog 18 Item Description Spare part number Customer self repair (on page 5 ) d) HP NC364m Quad Port 1GbE BL-c Adapter 448066-001 Mandatory 1 e) HP NC382m Dual Port 1GbE Multifunction BL-c Adapter 462748-001 Mandatory 1 f) HP NC512m Dual Port 10GbE Multifun ction BL-c Adapter 448515-001 Mandatory 1 g) HP NC532m Dual Port Fle x-1[...]
-
Page 19
Illustrated parts catalog 19 3 No—Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP requires that an authorized service provider re place the part. These parts are identified as "No" in the Illustrated Parts Catalog. 1 Mandatory: Obligatoire—Pièces pour lesquelles la réparation pa[...]
-
Page 20
Illustrated parts catalog 20 2 Optional: Opcional—Peças cujo reparo feito pelo cl ient e é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto. 3 No: Nenhuma[...]
-
Page 21
Removal and replacement procedures 21 R emo v al and r eplacement pr ocedur es Required tools You need the following item s for some procedures: • T-15 Torx screwdriver (provided inside the access panel) • HP Insight Diagnostics soft ware (" HP Insight Diagnostics " on page 53 ) Safety considerations Before performing service proced u[...]
-
Page 22
Removal and replacement procedures 22 CAUTION: When performing non-hot-plug operatio ns, you must power down the serv er blade and/or the system. However, it may be necessar y to leave the server blade powered up when performing other operations, such as hot- plug installations or troubleshooting. Symbols on equipment The following symbols may be p[...]
-
Page 23
Removal and replacement procedures 23 Power down the server blade Before powering down the server blade for any up grade or maintenance procedures, perform a backup of critical server data and programs. Depending on the Onboard Administrator configuration, use one of the followin g methods to power down the server blade: • Use a virtual power but[...]
-
Page 24
Removal and replacement procedures 24 3. Remove the server blade. 4. Place the server blade on a flat, level work surface. WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical componen ts, properly ground the serve[...]
-
Page 25
Removal and replacement procedures 25 CAUTION: To prevent damage to electrical componen ts, properly ground the server blade before beginning any installation procedure. Improper ground ing can cause ESD. To replace the component: 1. Place the access panel on top of the server blade. Allow the panel to extend past the rear of the server blade appro[...]
-
Page 26
Removal and replacement procedures 26 3. Remove the hard drive. To replace the component, reverse the r emoval procedure. Solid state drive WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. To remove the component: 1. Power down the server blade (on pa[...]
-
Page 27
Removal and replacement procedures 27 To replace the component, reverse the r emoval procedure. DIMM baffle CAUTION: To avoid damage to the server blade and the enclosure, install all DIMM baffles in the proper location after adding or replacin g DIMMs. DIMM baffles that are missing or installed incorrectly can compromise server blade and enclosure[...]
-
Page 28
Removal and replacement procedures 28 6. Remove the DIMM. When replacing DIMMs for processors 3 and 4, it may be helpful to remove the following items: • Hard drives (" Hard drive " on page 25 ) • SAS controller (on page 29 ) • Front panel/hard drive cage assembly (on page 33 ) To replace the component, reverse the r emoval procedur[...]
-
Page 29
Removal and replacement procedures 29 o Mezzanine 1 and 2 o Mezzanine 3 CAUTION: To prevent damage to the server bl ade, apply pressure over the mezzanine connector when installing the mezzanine card. Do not apply pressure to the edges of the c ard. To replace the component, reverse the r emoval procedure. SAS controller To remove the component: 1.[...]
-
Page 30
Removal and replacement procedures 30 4. Remove the controller. To replace the component, reverse the r emoval procedure. Battery-backed write cache procedures Two types of procedures ar e provided for the BBWC option: • Removal and replacement of failed components: o Removing the cach e module (" Cache module " on page 30 ) o Removing [...]
-
Page 31
Removal and replacement procedures 31 4. Remove the cache module. To replace the component, reverse the r emoval procedure. Cache module battery pack To remove the component: 1. Power down the server blade (on page 23 ). 2. Remove the server blade (on page 23 ). 3. Remove the access panel (" Access panel " on page 24 ). 4. Remove the batt[...]
-
Page 32
Removal and replacement procedures 32 o Mezzanine card controller option 5. Disconnect the battery pack. To replace the component, reverse the r emoval procedure. Recovering data from the battery-backed write cache If the server fails, use the follow ing procedure to recover data temporarily stored in the BBWC. CAUTION: Before starting this pr oced[...]
-
Page 33
Removal and replacement procedures 33 o Find a server that has enough empty drive bays to accommodate all the drives from the failed server and that meets all the other requ irements for drive and array migration. 2. Power down the failed server (" Power down the server blade " on page 23 ). If any data is stored in the cache module, a gr[...]
-
Page 34
Removal and replacement procedures 34 Server blade release lever and button To remove the component: 1. Power down the server blade (on page 23 ). 2. Remove the server blade (on page 23 ). 3. Remove the access panel (" Access panel " on page 24 ). 4. Remove all hard drives (" Hard drive " on page 25 ). 5. Remove all hard drive b[...]
-
Page 35
Removal and replacement procedures 35 To replace the component, reverse the r emoval procedure. Heatsink To remove the component: 1. Power down the server blade (on page 23 ). 2. Remove the server blade (on page 23 ). 3. Remove the access panel (" Access panel " on page 24 ). 4. To replace heatsink 3 or 4, perform these additional steps: [...]
-
Page 36
Removal and replacement procedures 36 2. Remove the thermal interface prot ective cover from the heatsink. CAUTION: Heatsink retaining screws sho uld be tigh tened in diagonally o pposite pairs (in an "X" pattern). IMPORTANT: When installing the heatsink, align the guide pins on the processor retention bracket with the alignment holes in [...]
-
Page 37
Removal and replacement procedures 37 Processor WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: To prevent possible serv er malfunction, do not mix processors of different speeds or cache sizes. Refer to the label on the proces so r heatsink[...]
-
Page 38
Removal and replacement procedures 38 6. Using your fingers, remove the failed pro cessor. To replace the component: CAUTION: The pins on the proces sor socket are very fragile. Any damage to them may require replacing the system board. CAUTION: Failure to completely open t he processor locking lever prevents the processor fr om seating during inst[...]
-
Page 39
Removal and replacement procedures 39 1. If the processor has separated from the installation tool, carefully re-insert the processor in the tool. 2. Align the processor installation tool with the socket and install the processor. CAUTION: The processor is design ed to fit one way into the socket. Use the alignment guides on the processor and socke[...]
-
Page 40
Removal and replacement procedures 40 3. Press down firmly until the proces sor installation tool clicks and separates from the processor, and then remove the processor installation tool. 4. Close the processor retaining bracket and the processor retaining latch. 5. Clean the old thermal grease from the he atsink with the alcohol swab. Allow the al[...]
-
Page 41
Removal and replacement procedures 41 7. Remove the thermal interface prot ective cover from the heatsink. CAUTION: Heatsink retaining screws sho uld be tigh tened in diagonally o pposite pairs (in an "X" pattern). IMPORTANT: When installing the heatsink, align the guide pins on the processor retention bracket with the alignment holes in [...]
-
Page 42
Removal and replacement procedures 42 8. Install the heatsink. 9. Install the front panel/hard drive cage assembly (" Front panel/hard drive cage assembly " on page 33 ), if removed. 10. Install the SAS controller (" SAS controller " on page 29 ), if removed. 11. Install the hard drives (" Hard drive " on page 25 ), if[...]
-
Page 43
Removal and replacement procedures 43 5. Remove the battery. IMPORTANT: Replacing the system board battery resets the system ROM to its default configuration. After replacing the battery , reconfigure t he system through RBSU. To replace the component, reverse the r emoval procedure. System board To remove the component: 1. Power down the server bl[...]
-
Page 44
Removal and replacement procedures 44 13. Open the processor retaining latch and the processor socket retaining bracket. 14. Using your fingers, remove the proces sor from the failed system board. CAUTION: To avoid damage to the system board: • Do not touch the processor socket contacts. • Always install the processor socket cover after removin[...]
-
Page 45
Removal and replacement procedures 45 o Near mezzanine card connector o Near SD card slot[...]
-
Page 46
Removal and replacement procedures 46 16. Remove the failed system board. To replace the system board: 1. Install the spare system board. 2. Prepare the processor socket on the spare syst em board:[...]
-
Page 47
Removal and replacement procedures 47 a. Remove the processor socket protective cover. b. Open the processor retaining latch and the processor socket retaining bracket. 3. Install the processor socket cove r onto the processor socket of the failed system board. 4. Install the processor on the spare system board. CAUTION: The processor is design ed [...]
-
Page 48
Removal and replacement procedures 48 5. Close the processor retaining latch and th e processor socket retaini ng bracket. 6. Clean the old thermal grease from the he atsink an d the top of the proc essor with the alcohol swab. Allow the alcohol to evapo rate before continuing. 7. Apply all the grease to the top of the processor in one of the foll [...]
-
Page 49
Removal and replacement procedures 49 IMPORTANT: Heatsinks for processors 1 and 2 are no t interchangeable with the heatsinks for processors 3 and 4. 8. Install the heatsink. IMPORTANT: Install all components with the same co nfiguration that was used on the failed system board. 9. Install the BBWC battery holders. 10. Install all components remove[...]
-
Page 50
Cabling 50 Cabl i n g SSD cable routing Using the HP c-Class Blade SUV Cable The HP c-Class Blade SUV Cable enables the user to perform server blade adminis tration, configuration, and diagnostic procedures by connecting video and USB devices directly to the server blade. For SUV cable connectors, see "HP c-Class Blade SUV Cable (on page 64 ).[...]
-
Page 51
Cabling 51 Accessing a server blade with local KVM CAUTION: Before disconnecting the SUV cable from t he connector, always squeeze the release buttons on the sides of the connector. Failure to do so can result in damage to the equipment. NOTE: For this configuration, a USB hub is not nec essary. To connect additional devices, use a USB hub. 1. Conn[...]
-
Page 52
Cabling 52 4. Connect the following to the USB hub: o USB CD/DVD-ROM drive o USB keyboard o USB mouse o USB diskette drive NOTE: Use a USB hub when connecting a USB di skette drive and/or USB CD-ROM drive to the server blade. The USB hub pr ovides additional connections. Item Description 1 Monitor 2 USB mouse 3 HP c-Class Blade SUV Cable 4 Server b[...]
-
Page 53
Diagnostic tools 53 Di agnosti c tools Troubleshooting resources The HP ProLiant Servers Troubleshoot ing Guide provides procedures for resolving common problems and comprehensive courses of action for fault isolation an d identification, error message interpretation, issue resolution, and software maintenance on ProLiant ser v ers and server blade[...]
-
Page 54
Diagnostic tools 54 You can view recorded events in the IML in several ways, including t he following: • From within HP SIM • From within operating system-specific IML viewer s: o For NetWare: IML Viewer o For Windows®: IML Viewer o For Linux: IML Viewer Application • From within the iLO 2 user interface • From within HP Insight Diagnostic[...]
-
Page 55
Diagnostic tools 55 agreements. Download from the HP website ( http://h20392.www2.hp.com/portal/swdepot/di sp layProductInfo.do? productNumber=ISDVD ). Both HP Insight Remote Support solutions are availabl e at no additional cost to customers with a valid warranty on HP technology, an HP Care Pack Se rvice or HP contractual support agreement. For m[...]
-
Page 56
Component identification 56 C omponen t identif icati on Front panel components Item Description 1 Serial label pull tab 2 HP c-Class Blade SUV Cable connec tor* 3 Power On/Standby button and LED 4 Server blade release button 5 Server blade release lever 6 Hard drive ba y 2 7 Hard drive ba y 1 * The SUV connector and the HP c-Class Blade SUV Cable [...]
-
Page 57
Component identification 57 Item Description Status 2 Health LED Green = Normal operation Amber flashing = Degraded condition Red flashing = Critica l condition 3 Flex 1 LED Green = Network linked Green flashing = Network activity Off = No link or activity 4 Flex 2 LED Green = Network linked Green flashing = Network activity Off = No link or activi[...]
-
Page 58
Component identification 58 Item Description 1 Fault/UID LED (amber/blue) 2 Online LED (green) SAS and SATA hard drive LED combinations NOTE: Predictive failure alerts can occur only when the hard drive is connected to a Smart Array controller. Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation On, off, or flashing Alternating am[...]
-
Page 59
Component identification 59 System board components Item Description 1 Processor 4 DIMM slots 2 Processor socket 4 3 Processor socket 2 (populated) 4 System maintenance switch 5 Processor 2 DIMM slots 6 Mezzanine connector 1 (Type I mezzanine only) 7 Mezzanine connector 2 (Type I or Type II mezzanine) 8 System board thumbscrews (3) 9 Enclosure conn[...]
-
Page 60
Component identification 60 The symbols correspond to the symbols located on the inte rconnect bays. For more information, see the HP ProLiant BL685c G6 Serve r Blade Installation Instructions that ship with the server blade. Mezzanine connector definitions PCIe x8 mezzanine connec tors support x16 cards at up to x8 speeds. Item Connector Card supp[...]
-
Page 61
Component identification 61 • Processor 2 DIMM slots • Processor 3 DIMM slots[...]
-
Page 62
Component identification 62 • Processor 4 DIMM slots System maintenance switch Position Function Default 1* iLO 2 security override Off 2 Configuration lock Off 3 Reserved Off 4 Reserved Off 5* Password disabled Off 6* Reset configuration Off 7 Reserved Off 8 Reserved Off *To access redundant ROM, set S1, S5, and S6 to ON. System maintenance swit[...]
-
Page 63
Component identification 63 3. Remove the access panel (" Access panel " on page 24 ). 4. Change position 6 of the system maintena nce switch to on. 5. Install the access panel (" Access panel " on page 24 ). 6. Install the server blade in the enclosure and power up the server blade. 7. Wait for the POST message that prompt s yo[...]
-
Page 64
Component identification 64 HP c-Class Blade SUV Cable Item Connector Description 1 Server blade For connecting to the SUV connector on the server blade front panel 2 Video For connecting a video monitor 3 USB For connecting up to two USB devices 4 Serial For trained personnel to connect a null modem serial cable and perform advanced diagnostic pro[...]
-
Page 65
Specifications 65 Sp e c i fic a t io n s Environmental specifications Specification Value Temperature range* Operating 10 ° C to 35 ° C (50 ° F to 95 ° F) Shipping -40 ° C to 60 ° C (-40 ° F to 140 ° F) Storage -20°C to 60°C (-4°F to 140°F) Maximum wet bulb temperature 30 ° C (86 ° F) Relative humidity (noncondensing)** Operating 10%[...]
-
Page 66
Acronyms and abbreviations 66 A c r on y ms and abbr e v iati ons ADU Array Diagnostics Utility CSR Customer Self Repair ESD electrostatic discharge FC Fibre Channel HBA host bus adapter iLO 2 Integrated Lights-Out 2 IML Integrated Management Log PCI peripheral component interface PCIe peripheral component interconnect express RBSU ROM-Based Setup [...]
-
Page 67
Acronyms and abbreviations 67 SFF small form-factor SIM Systems Insight Manager TPM trusted platform module UID unit identification USB universal serial bus[...]
-
Page 68
Index 68 A access panel 24 ADU (Array Diagnostic Utility) 54 air baffle 27 B baffles 27 battery 42 battery pack, removing 31 battery-backed write cache battery pack 31 BBWC (battery-backed write cache) 30, 31 buttons 56 C cables 50 cabling 50 cache battery 31 cache module 30 cache module battery pack 31 cache module, removing 30 caution[...]
-
Page 69
Index 69 S safety considerations 21 safety information 21 SAS backplane 29 SAS controller 29 SAS drives 25, 58 SAS hard drive LEDs 57, 58 SAS/SATA LED combinations 58 SATA hard drive 58 SATA hard drive LEDs 57, 58 server blade release lever 34 solid state drive 26 spare part numbers 16 specifications 65 specifications, environmental 65 static e[...]