HP (Hewlett-Packard) D-04 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of HP (Hewlett-Packard) D-04, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of HP (Hewlett-Packard) D-04 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of HP (Hewlett-Packard) D-04. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of HP (Hewlett-Packard) D-04 should contain:
- informations concerning technical data of HP (Hewlett-Packard) D-04
- name of the manufacturer and a year of construction of the HP (Hewlett-Packard) D-04 item
- rules of operation, control and maintenance of the HP (Hewlett-Packard) D-04 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of HP (Hewlett-Packard) D-04 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of HP (Hewlett-Packard) D-04, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the HP (Hewlett-Packard) service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of HP (Hewlett-Packard) D-04.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the HP (Hewlett-Packard) D-04 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Models: D-04, G-04 INST ALLA TION & SERVICE W ANNER ENGINEERING, INC. 1204 Chestnut A venue, Minneapolis, MN 55403 TEL: (612) 332-5681 F AX: (612) 332-6937 T OLL-FREE F AX [US only]: (800) 332-6812 www .hydra-cell.com email: sales@wannereng.com INDUSTRIAL PUMPS[...]

  • Page 2

    2 D04-991-2400 5/1/04 Max Pressure 2,500 psi (170 bar) Capacity @ Max Pressure rpm gpm I/min D/G-04-X 1750 2.9 1 1.0 D/G-04-E 1750 2.1 7.8 D/G-04-S 1750 1.6 6.1 Delivery @ Rated Pressure revs/gal 500 psi 1500 psi 2500 psi D/G-04-X 565 583 603 D/G-04-E 761 795 833 D/G-04-S 921 972 1,093 revs/liter 35 bar 100 bar 170 bar D/G-04-X 149 154 159 D/G-04-E[...]

  • Page 3

    3 D04-991-2400 5/1/04 RPM 0 NPSHr (feet of water) 1750 1 2 3 4 5 6 7 8 9 10 11 12 0 200 400 600 800 1000 1200 1400 1600 1800 D/G-04-X D/G-04-E D/G-04-S NPSHr (meters of water) 1.0 2.0 3.0 2.5 3.5 0 .5 1.5 0 RPM 0 200 400 600 800 1000 1200 1400 1600 1800 1750 500 PSI (35 bar) 1500 PSI (100 bar) 2500 PSI (170 bar) 12.5 0 11.25 10 8.75 7.5 6.25 5.0 3.[...]

  • Page 4

    4 D04-991-2400 5/1/04 D/G-04 Dimensions D/G-04 Models with Metallic Pumping Head Brass 304 Stainless Steel 316 Stainless Steel 7.01 (178) 10.38 (263.7) Outlet D-04: 1/2" NPT G-04: 1/2" BSPT D-04: 1/2" NPT G-04: 1/2" BSPT Inlet 9.93 (252.2) 2.25 (57.2) 8.71 (221.2) 2.25 (57.2) 2.75 (69.9) 2.75 (69.9) 3.35 (85.1) 0.75 (19.1) 0.75 [...]

  • Page 5

    5 D04-991-2400 5/1/04 D/G-04 Installation NOTE: The numbers in parentheses are the Reference Numbers on the illustrations in the Parts Manual. Location Locate the pump as close to the supply source as possible. Install it in a lighted clean space where it will be easy to inspect and maintain. Allow room for checking the oil level, changing the oil,[...]

  • Page 6

    6 D04-991-2400 5/1/04 D/G-04 Installation Inlet Calculations Acceleration Head Calculating the Acceleration Head Use the following formula to calculate acceleration head losses. Subtract this figure from the NPSHa, and compare the result to the NPSHr of the Hydra-Cell pump. Ha = (L x V x N x C) ÷ (K x G) where: Ha = Acceleration head (ft of liquid[...]

  • Page 7

    7 D04-991-2400 5/1/04 D/G-04 Installation Discharge Piping NOTE: Consult the Factory before manifolding two or more pumps together . NOTE: Single-acting pumps create a pulsing flow. Using pulsation dampening devices in the discharge line can reduce or eliminate this. Hose and Routing Use the shortest, most-direct route for the discharge line. Selec[...]

  • Page 8

    8 D04-991-2400 5/1/04 Before Initial Start-Up Before you start the pump, be sure that: • All shutof f valves are open, and the pump has an adequate supply of fluid. • All connections are tight. • The oil level is 1/4 inch (6 mm) above the cast surface in the upper oil reservoir . • The relief valve on the pump outlet is adjusted so the pump[...]

  • Page 9

    9 D04-991-2400 5/1/04 D/G-04 Maintenance NOTE: The numbers in parentheses are the Ref. Nos. on the illustrations in the Parts Manual. Daily Check the oil level and the condition of the oil. The oil level should be 1/4 in. (6 mm) above the cast surface in the upper oil reservoir . Use the appropriate Hydra-Oil for the application (contact Wanner Eng[...]

  • Page 10

    10 D04-991-2400 5/1/04 D/G-04 Service (Fluid End) Bolt T orque Specifications Ref. No. D-04 G-04 1 50 ft-lbs 70 Nm 17 10 in-lbs 1 10 Ncm[...]

  • Page 11

    11 D04-991-2400 5/1/04 D/G-04 Service (Fluid End) NOTE: The number in parentheses are the Reference numbers on the illustration at right and in the Parts Manual. This section explains how to disassemble and inspect all easily serviceable parts of the pump. Repair procedures for the hydraulic end (oil reservoir) of the pump are included in a later s[...]

  • Page 12

    12 D04-991-2400 5/1/04 D/G-04 Service (Fluid End) 3. Inspect and Replace Diaphragms (17) a. Lift a diaphragm by one edge, and turn the pump shaft until the diaphragm moves up to “ top dead center ” . This will expose machined cross-holes in the plunger shaft behind the diaphragm. b . Insert the plunger holder tool through one of the machined cr[...]

  • Page 13

    13 D04-991-2400 5/1/04 D/G-04 Service (Fluid End) 6. Reinstall V alve Plate (12) and Manifold (3) a. Reinstall the valve plate (12), with the valve assemblies installed as outlined above, onto the diaphragm plate (18) and alignment pins (29). Tighten the two socket-head capscrews evenly and snugly to compress the outer diaphragm beads and hold the [...]

  • Page 14

    14 D04-991-2400 5/1/04 D/G-04 Service (Hydraulic End)[...]

  • Page 15

    15 D04-991-2400 5/1/04 D/G-04 Service (Hydraulic End) NOTE: The numbers in parentheses are the Ref. Nos. on the illustrations in the Parts Manual. This section explains how to disassemble and inspect the hydraulic end (oil reservoir) of the pump. CAUTION: Do not disassemble the hydraulic end unless you are a skilled mechanic. For assistance, contac[...]

  • Page 16

    16 D04-991-2400 5/1/04 D/G-04 Service (Hydraulic End) 3. Replace Shaft Seal NOTE: Inspect the shaft seal (54) before continuing. If it looks damaged in any way , replace it. a. Press the back bearing (55) and seal (54) out of the cover (52). Discard the seal. b. Apply a coating of Loctite High-Performance Pipe Sealant with T eflon © , or a compara[...]

  • Page 17

    17 D04-991-2400 5/1/04 D/G-04 T roubleshooting Cavitation • Inadequate fluid supply because: — Inlet line collapsed or clogged — Clogged line strainer — Inlet line too small or too long — Air leak in inlet line — Worn or damaged inlet hose — Suction line too long — T oo many valves and elbows in inlet line • Fluid too hot for inle[...]

  • Page 18

    18 D04-991-2400 5/1/04 V alve Wear • Normal wear from high-speed operation • Cavitation • Abrasives in the fluid • V alve incompatible with corrosives in the fluid • Pump running too fast Loss of Oil • External seepage • Rupture of diaphragm • Frozen pump • Worn shaft seal • Oil drain piping or fill cap loose. • V alve plate a[...]

  • Page 19

    19 D04-991-2400 5/1/04 Limited W arranty W anner Engineering, Inc. extends to the original purchaser of equipment manufacturerd by it and bearing its name, a limited one-year warranty from the date of purchase against defects in material or workmanship, provided that the equipment is installed and operated in accordance with the recommendations and[...]

  • Page 20

    20 D04-991-2400 5/1/04 W ANNER ENGINEERING, INC. 1204 Chestnut A venue, Minneapolis, MN 55403 TEL: (612) 332-5681 F AX: (612) 332-6937 T OLL-FREE F AX [US only]: (800) 332-6812 www .hydra-cell.com email: sales@wannereng.com ©2004 W anner Engineering, Inc. Printed in USA[...]