Go to page of
Similar user manuals
-
Server
HP (Hewlett-Packard) ML570
48 pages 0.43 mb -
Server
HP (Hewlett-Packard) 8200zl/5400zl/3500yl Series
12 pages 0.23 mb -
Server
HP (Hewlett-Packard) DL160
50 pages 1.36 mb -
Server
HP (Hewlett-Packard) 9250C
98 pages 7.36 mb -
Server
HP (Hewlett-Packard) 512485-B21
14 pages 0.23 mb -
Server
HP (Hewlett-Packard) 354
140 pages 2.64 mb -
Server
HP (Hewlett-Packard) PA 8800
44 pages 0.27 mb -
Server
HP (Hewlett-Packard) BH3700
69 pages 5.51 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of HP (Hewlett-Packard) GbE2, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of HP (Hewlett-Packard) GbE2 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of HP (Hewlett-Packard) GbE2. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of HP (Hewlett-Packard) GbE2 should contain:
- informations concerning technical data of HP (Hewlett-Packard) GbE2
- name of the manufacturer and a year of construction of the HP (Hewlett-Packard) GbE2 item
- rules of operation, control and maintenance of the HP (Hewlett-Packard) GbE2 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of HP (Hewlett-Packard) GbE2 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of HP (Hewlett-Packard) GbE2, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the HP (Hewlett-Packard) service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of HP (Hewlett-Packard) GbE2.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the HP (Hewlett-Packard) GbE2 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
ProLiant BL p-Cl ass GbE2 Interconnect Swit ch Overview white paper Abstract .............................................................................................................................................. 3 Introduction ...................................................................................................................[...]
-
Page 2
Enterprise-class perf ormance ................................................................................................... ............ 16 Network adapter team ing ........................................................................................................ ........... 16 Conclusion ................................................[...]
-
Page 3
3 Abstract This white paper provides an overview of the second generation Gigabit Ethernet (GbE2) Interconnect Kit options for the ProLiant BL p-Class system. Each GbE2 Interc onnec t Kit includes a pair of industry- standard Ethernet switches that dramatically reduce the number of E thernet network cables attached to the rear of the ProLiant BL p-[...]
-
Page 4
4 GbE2 Interconnect Kit The GbE2 Interconnect Kit contains two redundant, hot-swappable GbE2 Interconnect Switches and two 4-port LAN interconnect modules. Users first insert the LAN interconnect modules into the bottom- left and bottom-right interconnect bays at the rear of the server blade enclosure and then install the interconnect switches into[...]
-
Page 5
5 redundant fans and they are powered by two independent feeds via the redundant, N+N hot-plug ProLiant BL p-Class power enclosure. Users can independently disable or enable the switch ports as desired. Auto-MDI/MDIX with auto- negotiation of speed and duplex mode is supported. Each GbE2 Interconnect S witch includes the following Ethernet ports: ?[...]
-
Page 6
6 LAN in tercon nec t mod ule u plin k po rts The LAN int erconnect module uplink ports are typically us ed to connect the inte rconnect switches to the network infrastructure; however, they are standard Ethernet switch ports and may be used as desired. The GbE2 interconnect kits are identic al with exception of the LAN interconnect modules. The C-[...]
-
Page 7
7 module that contain a 10-Gb Ethernet high-bandwidth uplink. The 10-Gb LAN interconnect modules may also contain Gigabit Ethernet ports, if space permit s. With these future planned options for the GbE2 Intercon nect Switch, an administrator will be able to independently select the switching layer as well as the uplink bandwidth, all within a sing[...]
-
Page 8
8 Applications that utilize a single uplink port include testing and ev aluation systems, server blade enclosures with a few installed servers, and applications that require minimal band width. On a heavily utilized system, using a single uplink port for all 32 network adapters can cause a traffic bottleneck. For example, u sing one uplink from int[...]
-
Page 9
9 Fibre Chann el pass-through The GbE2 Interconnect Kits offer the ability to pass-through BL20p G2 Fibre Channel signals using the optional GbE2 Storage Connectivity Kit. Therefore, both Ethernet LAN signal consolidation and Fibre Channel SAN signal pass-through is now possible with a single interconnect. The GbE2 Interconnect Switch chassis is si[...]
-
Page 10
10 Figure 5. BL20p G2 Fibre Channel signal routing with the GbE2 Interconnect Swit c h With the GbE2 Storage Connectivity Kit installed, both Fibre Channel SAN and Ethernet LAN signals exit the rear of the server blade enclosure, each type of signal on its dedicated interconnect module (Figure 6). Just like the LAN QuadT2 and QuadSX interc onnect m[...]
-
Page 11
11 Switch management The GbE2 Interconnect Switch is an industry-standard managed Ethernet switch, which means that users configure and manage the switch like other industry-standard Ethernet switches. To aid users during initial deployment, the GbE 2 Interconnect Switch includes a default configuration that is ful ly operational at initial boot an[...]
-
Page 12
12 configuration file. The confi guration file has a text-based format, which allows it to be directly viewed, printed, and edited. E ach GbE2 Inte rconnect Switch has thre e configuration s ettings in memory (active, back-up, and fac to ry); any one o f these settings can be selected as the cu r rent runtime version . Users can perform firmware op[...]
-
Page 13
13 Script able co mman d line int erface The CLI provides the added benefits of scripting, a set-up utility and other enhanced switch management tas ks, an out-of-band connection, and more. T he main menu opens aft er a successful log- in (Figure 9). This interface may be accessed locally via the front panel RS-232 console po rt o n eac h interconn[...]
-
Page 14
14 • Specify the IP-based management networks that are allowed to access each switch. • Set a user interface idle time-out period and disable web-based and Telnet access. • Enable a secure shell (SSH) session to the C LI interfac e. • Modify default Telnet and HTTP server socket port numbers. Additional switch se curity meas ures include: ?[...]
-
Page 15
15 The optional HP Diagnostic Station (Figure 11) is available to configure and diagnose an interconnect switch or a server blade that has been removed from the server blade enclosure. The Diagnostic Station provides power to the interconnect switch and can be used to perform any of the following tasks: • Build the initial interconnect switch con[...]
-
Page 16
16 • The ability to set the interconnect switch to a v alid firmware image in case of firmware corruption. For more detailed information on the administration ca pabilities of the ProLiant BL p-Class GbE2 Interconnect Sw itch, see the ProLiant BL p- Class GbE2 Interconnect Switch user g uides. 6 Virtual LAN The GbE2 Interco nn ec t Switc h su ppo[...]
-
Page 17
17 • Network Fault Tolerance (NFT) • Transmit Load Balancing (TLB) • Switch-assisted Load Balanc ing (SLB) When teaming HP NC series network adapters with the interconnect switch, NFT and TLB teaming are the same as with any ProLiant system. However, for SLB teaming, the pre-defined switch-to-server architecture across the server blade enclos[...]
-
Page 18
18 Appendix: S ummary of features of th e ProLiant BL p -Class GbE2 Interconnect Kit Switc h perfor mance • Store an d for ward mode l ayer 2 s witchin g stand ard • Layer 3 routi ng firmw are future internal upg rad e capabi lity • Layer 7 rout ing an d cont ent d elivery switch ing f uture in ternal upgr ade ca pabil ity • Suppor t for 3r[...]
-
Page 19
19 • MAC ad dress u ser m anagem ent s ortin g on a per p ort an d per VL AN basis • Manual, or automatic IP s ettings via a BOO TP server • Three switch c onfigurat ion settings in mem ory ( active, b ack-up , and f actory ); any can b e selected as the curr ent versi on. • Redund a nt firmwa re i mages in memo ry; ei t h e r image can be [...]
-
Page 20
20 • State infor mation ”dump ” for tuning and debugg ing swit ch per form ance availa ble in u uenc oded f ormat • Panic c omman d for immed iate st ate du mp t o flash memor y an d auto matic ally sw itch re boot Switch security • Passw ord pr otecte d mul ti-level user accou nts su pport ed on all m anage ment in terfac es • Configur[...]
-
Page 21
21 Switc h ports per server blade enclo sure • Eight external 10/100/1000T (C-GbE 2) or 1000SX (F-GbE2) Gigabit E t hernet ports on a hot-pluggable rear-mounted interco nne ct module • Four external 10/100/1000T Gigabit E t hernet ports on switch front panels • Two ex terna l DB-9 se rial port s o n switc h fro nt panels (o ne per swit ch) ?[...]
-
Page 22
For more i nform ation For additional information, r efer to the resources detailed below. Resourc e d escription Web addr es s ProLian t BL p-Clas s GbE2 Interconn ect sw itch h om e pa ge http://h18004.www1.hp.com/products/se rvers/proliant-bl/p- class/bl-p- interconnect-switch2.html ProLian t BL p-Clas s Netw orkin g Overview white paper http://[...]