Go to page of
Similar user manuals
-
Network Card
HP HP RP7405/7410
146 pages 2.77 mb -
Computer Monitor
HP L1740
52 pages 0.83 mb -
Notebook
HP OMEN 15-ax202
70 pages 1.48 mb -
All in One Printer
HP OFFICEJET PRO 8000 A809
140 pages 4.83 mb -
Printer
HP ENVY 5532
108 pages 2.12 mb -
Printer
HP Color LaserJet 4600n
244 pages -
All in One Printer
HP OFFICEJET 6100
88 pages 1.95 mb -
Printer
HP LaserJet 4100DTN
278 pages 6.77 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of HP Clemco 60 HP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of HP Clemco 60 HP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of HP Clemco 60 HP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of HP Clemco 60 HP should contain:
- informations concerning technical data of HP Clemco 60 HP
- name of the manufacturer and a year of construction of the HP Clemco 60 HP item
- rules of operation, control and maintenance of the HP Clemco 60 HP item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of HP Clemco 60 HP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of HP Clemco 60 HP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the HP service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of HP Clemco 60 HP.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the HP Clemco 60 HP item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR CLEMCO SUPPLIED AIR RESPIRA T OR MODEL 60 HP O.M. 10533 690-0985 09/85 K, 05/15/98 MC FILE NUMBER: DATE OF ISSUE: REVISION: WARNING Do not proceed with these instructions until you have READ the orange cover of this MANU AL and Y OU UNDERST AND its content.* These W ARNINGS are included for the health and safety[...]
-
Page 2
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR x 04440 Flow Regulator x 04410 Flow Regulator x 04411 Flow Regulator x 21422 Cont. Flow Conn. x 04397 Hose 25 Ft. x 04415 Hose 50 Ft. x 04398 Hose 100 Ft. Page 1 Clemco Industries Corp. W ashington, Missouri USA (314) 239-0300 TYPE C AND CE CONTINUOUS FLO W SUPPLIED-AIR RESPIRA TOR IS APPRO VED ONL Y IN THE FOLL[...]
-
Page 3
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 2 ! W ARNING “Warning” is used to indicate a potentially haz- ardous situation which, if not avoided, could result in death or serious injury. ! DANGER “Danger” is used to indicate an imminently haz- ardous situation which, if not avoided, will result in death or serious injury. 1.3 Respiratory and [...]
-
Page 4
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 3 This manual does not contain all the health and safety requirements regarding toxic and hazard- ous dust exposure. Obtain copies of the OSHA regulations and consult a safety professional and/or industrial hygienist for complete require- ments. Within this manual we refer to hazardous or con- taminated env[...]
-
Page 5
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 4 bels. (42 CFR part 84.140) When any exterior noise causes the internal noise level to exceed 80 decibels, the user must wear additional hearing protection. A variety of hearing protectors can be worn with the respirator. 1.7 Description 1.7.1 The Clemco Apollo 60 Supplied-Air Respirator is approved by the[...]
-
Page 6
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 5 2.0 INSPECTION ! NOTICE A Clemco respirator hose must be used with the Apollo Respirator. If one is not available, it must be ordered from an authorized distributor of Clemco products. Hoses are not included with respirators, because blast operators often are assigned personal respirators, while using com[...]
-
Page 7
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 6 connect the other end of the respirator hose to a respirable air source. If longer hose is required, it must be a NIOSH- approved Clemco respirator hose extension. Any 25 foot, 50 foot and 100 foot respirator hoses can be added in any combination to produce the maximum total length as noted in the table i[...]
-
Page 8
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 7 monoxide removal or conversion system may also be used to ensure breathing air quality. The maximum allowable presence of carbon monoxide in Grade D breathing air is 10 parts per million (ppm). 4.2 Air Volume and Pressure 4.2.1 A pressure regulator and gauge must be installed at the point where the respir[...]
-
Page 9
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 8 5.1 Prior to operation, thoroughly inspect and clean the helmet, breathing tube, respirator hose, air entry ports, and fittings of all dust and debris. Inspect the helmet suspension and adjust if necessary per Section 6.2. 5.2 Start the compressor and open the service valve to pressurize the air supply li[...]
-
Page 10
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 9 6.2 Helmet Suspension Adjustment and Replacement, Figure 3 ! W ARNING The suspension maintains a fixed distance be- tween the head and the helmet. It is critical that the suspension is properly installed, and ad- justed as described, to provide maximum head protection and comfort. 6.2.1 Remove the cape fr[...]
-
Page 11
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 10 7.2.4 Periodically inspect and clean the foam filter and screen in the alternate air control valve. Replace the foam filter at first sign of blockage or deterioration. (See Section 9.8) 7.2.5 The inner collar is a very important factor in controlling air escape from the helmet and preventing ingress of d[...]
-
Page 12
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 11 8.4.3 If the acoustical foam on the inside of the helmet becomes soiled, it can be wiped with a damp cloth or pulled off and replaced. 8.5 Inner Lens 8.5.1 Inner lenses should be replaced when dirty or scratched; however mild detergent and water can be used to clean the inner lens. Volatile solutions suc[...]
-
Page 13
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR 9.4.2 Separate the Velcro tabs on the back of the cape. See Figure 5. 9.4.3 Slide the ends of the cape to the notch. Continue sliding one end of the cape out of the groove until the entire cape is detached from the helmet. 9.4.4 To install the cape, separate the Velcro tabs on the cape and slide one end into the[...]
-
Page 14
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Figure 6. (2) (1) (3, 4, 5) (6) (7) (9) (8) (10) (11) (12) (14) (13) (15) (16) (17) (18) (24) (19) (20) (22) (23) (21) Page 13 10.2 Supplied-Air Respirator, Figure 6 Item Description Stock No. 1. Constant-flow connector, HP (alternate), without belt ........................................ 21415 2. Belt assembly[...]