Go to page of
Similar user manuals
-
Thermostat
Hunter Fan T200
2 pages 0.16 mb -
Thermostat
Hunter Fan 42995
5 pages 0.07 mb -
Thermostat
Hunter Fan 44127
2 pages 4.23 mb -
Thermostat
Hunter Fan 47110A
7 pages 0.3 mb -
Thermostat
Hunter Fan 44428
22 pages 0.29 mb -
Thermostat
Hunter Fan 44760
28 pages 0.5 mb -
Thermostat
Hunter Fan 44260
7 pages 0.32 mb -
Thermostat
Hunter Fan 44360
56 pages 1.34 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Hunter Fan 40170, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hunter Fan 40170 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Hunter Fan 40170. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Hunter Fan 40170 should contain:
- informations concerning technical data of Hunter Fan 40170
- name of the manufacturer and a year of construction of the Hunter Fan 40170 item
- rules of operation, control and maintenance of the Hunter Fan 40170 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hunter Fan 40170 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hunter Fan 40170, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hunter Fan service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hunter Fan 40170.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Hunter Fan 40170 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Elec tronic/Me chanic al ermos tat Mo del 40170 installation and operation manual 42998-01 01-19-2007[...]
-
Page 2
2[...]
-
Page 3
3 T able of Contents Important Information.................................................. 5 T ools ............................................................................ 6 Uninstalling the Existing Unit ...................................... 9 Installing the Thermostat ........................................... 13 installing the wall plat[...]
-
Page 4
4 Congratulations! T hank you for choosing a Hunter thermostat. Y our new Hunter thermostat will provide years of reliable service and year -round energy savings . Please read this manual before beginning installation and save this booklet for complete operation instructions . Electronic/Mechanical Thermostat Model 40170[...]
-
Page 5
5 T his thermostat is designed to work on the following heating and cooling systems: Gas – Standing Pilot Gas – Electronic Ignition Gas – F ired Boilers Gas – Millivolt Systems Oil – F ired Boilers Oil – F ired Furnace Electric Furnace Electric Air Conditioning Single-stage Heat Pump Systems T his thermostat is not designed for Multi-st[...]
-
Page 6
6 T his thermostat includes two #8 slotted screws and two wall anchors for mounting. T o install your new thermostat, you will need the following supplies: Flat-head screwdriver ............................................................................................. Small Phillips-head screwdriver ..............................................[...]
-
Page 7
7 NO TICE! Do not disconnect the wires from the existing thermostat befor e reading these instructions . The wires must be labeled prior to removal to ensure pr oper reconnection.[...]
-
Page 8
8 UNINST ALLING THE EXISTING UNIT Y RC G W Y RC G W[...]
-
Page 9
9 1. T urn the system power OFF from the existing thermostat. T urn the power to the HV AC system OFF at the main power panel or at the furnace . 2. Remove the existing thermostat cover to access the wires from the wall. (Some thermostats may have multiple covers , screws or other locking devices that must be removed or disengaged.) 3. Locate , but[...]
-
Page 10
10 UNINST ALLING THE EXISTING UNIT , CONT . if your existing thermostat is marked... label the wire with this sticker: G / F G G W / H W W Y / C* / M Y Y RC / V C RC RC RH / R / VR / 4 RH RH 24 V olt 24 V olt cool air conditioning compressor heating fan O O O reversing valve cool B B B reversing valve heat[...]
-
Page 11
11 4. Using the provided stick ers , label each wire according to the chart. (If the terminals are not labeled, contact a qualified HV AC technician.) Note: Wire colors do not always comply with standards, so wire color should be ignored. Refer to the existing terminal designation for proper identification. *If wires mark ed Y & C are both pr[...]
-
Page 12
12 T op Cover T hermostat[...]
-
Page 13
13 INST ALLING THE THERMOST A T INST ALLING THE THERMOST A T 1. Remove the top cover from the new thermostat by pulling the two halves apart.[...]
-
Page 14
14[...]
-
Page 15
15 2. P osition the new thermostat on the w all and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter wall plate , or if there are no existing holes , level the thermostat and mark the wall for two holes . 4. Remove the thermostat and drill two 3/16” holes where mark ed. 5. T ap the plastic anch[...]
-
Page 16
16 INST ALLING THE THERMOST A T , CONT . G RC RH Y W B O R H R C W G B O Y[...]
-
Page 17
17 INST ALLING THE THERMOST A T , CONT . CONNECTING THE WIRES 1. Loosen, but do not remove , the terminal screws . Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not provide both an RH and RC wire. If you have both an RH and RC wire, remove this jumper . If you do not have both an RH and RC wire, leave[...]
-
Page 18
18 INST ALLING THE THERMOST A T , CONT . HG HE HP STD HE/HG Switch HP/STD Switch[...]
-
Page 19
19 A TT ACHING THE THERMOST A T 1. Locate the HE/HG switch on the wall plate . Set the switch to HG for a gas furnace or oil burner . Set the switch to HE for electric furnaces . (T he switch has no effect when the system is set to cooling mode .) 2. Locate the HP/STD switch on the wall plate . Set the switch to HP for Single-stage heat pump system[...]
-
Page 20
20 INST ALLING THE THERMOST A T , CONT .[...]
-
Page 21
21 3. Insert two fresh AA alkaline batteries. 4. Align the top cover with the the wall plate , and snap the two halves together . 5. Restore power at the electrical panel or furnace . INST ALLING THE THERMOST A T , CONT .[...]
-
Page 22
22 AUTO ON C OOL OFF HEAT SYSTEM 9 0 0 7 0 6 0 5 8 0 F an Switch System Switch Set T emperature Slider[...]
-
Page 23
23 OPERA TION 1. Set the Set Temperature slider to the desired temperature . 2. T he System Switch determines the operating mode of the thermostat. Select Cool, Off, or Heat. 3. T he Fan Switch should normally be located in the Auto position. T o run the fan continuously , slide the Fan Switch to the On position. Note: In Auto , The fan will be tur[...]
-
Page 24
24 INDICA TORS AND ADUSTMENT 0 5 0 6 0 7 8 0 9 0 T hermometer Battery Indicator[...]
-
Page 25
25 INDICA TORS AND ADUSTMENT 1. T he Thermometer indicates the room temperature . 2. T he Battery Indicator displays two battery conditions . The first w arning is the Weak Battery Warning , indicated by the Battery Indicator flashing once approximately every three seconds . When this warning appears , install two fresh AA alkaline batteries at y[...]
-
Page 26
26 SP AN Span Adjust SP AN[...]
-
Page 27
27 INDICA TORS AND ADJUSTMENTS, CONT . 1. Remove the top cover from the thermostat. 2. T o make your system run LONGER, turn the Span Adjust clockwise . 3. T o mak e your system run SHOR TER, turn the Span Adjust counter clockwise . 4. Reattach the top cover to the thermostat. Note: The Span range is 0.6 o F - 3 o F . The Span setting remains the s[...]
-
Page 28
28 1. My heating or cooling will not turn on or off . 1 a. Check the HE/HG switch to ensure it is set to the correct position. 1 b . Wait. T here may be as much as a 4-minute delay before the system turns on or off to protect the compressor . 1 c. Check the circuit breakers and switches to ensure there is enough power to the system. 1 d. Replace th[...]
-
Page 29
[...]
-
Page 30
30 G Rc Rh W Y F an Relay Heat/Cool 24V Supply Cool Contactor Heat Relay or V alve X Jumper 4-wire Heat/Cool System G Rc Rh F an Relay Heat 24V Supply W Heat Relay or V alve Y Cool Contactor 5-wire Heat/Cool System Cool 24V Supply[...]
-
Page 31
31 WIRING DIAGRAMS Reversing Valv e Compressor Contactor X Fan Relay Heat/Cool 24V Supply Single-stage Heat Pump System Cool Mode Heat Mode OR W G Rc Rh O B Y X Jumper Rc Rh W Heat 24V or Millivolt Supply Heat Relay or V alve X Jumper 2-wire Heat Only System[...]
-
Page 32
32 G Rc Rh W Heat 24V Supply Heat Relay or V alve X Jumper 3-wire Heat Only System Fan Relay G Rc Rh W Heat 24V Supply Heat Relay or V alve X Jumper 3-wire Heat Only System Fan Relay G Rc Rh Y Cool Contacter Cool 24V Supply X Jumper 3-wire Cool Only System F an Relay G Rc Rh Y Cool Contacter Cool 24V Supply X Jumper 3-wire Cool Only System F an Rel[...]
-
Page 33
33 © 2007 Hunter F an Company[...]