Go to page of
Similar user manuals
-
Thermostat
Hunter Fan 43157
2 pages 0.24 mb -
Thermostat
Hunter Fan 42711-01
55 pages 2.24 mb -
Thermostat
Hunter Fan 43057
13 pages 2.24 mb -
Thermostat
Hunter Fan 44155C
52 pages 2.11 mb -
Thermostat
Hunter Fan 42999 44050S
23 pages 0.57 mb -
Thermostat
Hunter Fan 43153
2 pages 0.23 mb -
Thermostat
Hunter Fan 40060
1 pages 0.03 mb -
Thermostat
Hunter Fan 44360
56 pages 1.34 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Hunter Fan 44760, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hunter Fan 44760 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Hunter Fan 44760. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Hunter Fan 44760 should contain:
- informations concerning technical data of Hunter Fan 44760
- name of the manufacturer and a year of construction of the Hunter Fan 44760 item
- rules of operation, control and maintenance of the Hunter Fan 44760 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hunter Fan 44760 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hunter Fan 44760, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hunter Fan service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hunter Fan 44760.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Hunter Fan 44760 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 Owner’ s Manual Model 44760 Auto T emp Heat Pump Thermostat ® 41652_model44760_web.pmd[...]
-
Page 2
2 2 Introduction CONGRA TULA TIONS! Y our new Hunter electronic thermostat will provide years of reliable service . By saving energy , your thermostat will pay for itself during its first season of use . T hank you for buying a Hunter product! Please read this manual for complete instructions on installing and operating your thermostat. If you requ[...]
-
Page 3
4 4 T able of Contents (continued) PROGRAMMING (continued) OPERA TIONS Program Options 30 Programmable F an 30 Reviewing Programs 30 P ower Switch 32 System Selection K ey 32 F an Key 33 System Indicator Light 34 Emergency Heat 35 Reviewing the Current T emperature Setting 35 T emporary Manual Override 36 P ermanent Manual Override 37 V acation (Pr[...]
-
Page 4
6 6 Read This Before Installing Thermostat IMPORT ANT 1 Read the entire installation section of this Owner’ s Manual thoroughly before you begin to install or operate your Hunter T hermostat. Remove the Mylar label from the LCD display window. INST ALLA TION 2 All installation is normally performed at your thermostat. ARMCHAIR PROGRAMMING 3 Y ou [...]
-
Page 5
8 8 Features INDIGLO ® Night-Light activated by pressing any k ey . Energy Monitor: Measures and displays heating and cooling system operating time for T oday, Y esterday , This Month, Last Month, or T otal. By monitoring your energy usage, you can program the thermostat to optimize energy savings. Home T oday: Overrides energy-saving program temp[...]
-
Page 6
10 10 INST ALLA TION W all Mounting Plate Thermostat Cover W all Mounting Plate Thermostat Cover What Y ou Need T his thermostat includes two #8 slotted screws and two w all an- chors for mounting. T o install your thermostat, you should have the following tools and materials . ■ Slotted Screwdriver(s) ■ Electric drill and 3/16" bit ■ Ph[...]
-
Page 7
12 12 INST ALLA TION TERMINAL FUNCTION LABELS (HEAT PUMP) COMMENTS R 24V AC supply Hot wire of 24V AC transformer . Powers the thermostat & system. Y1 Compressor stage 1 Activates the 1st stage compressor . (Heat or Cool for Heat Pumps) W2 Auxiliary heating Activates the 2nd stage (auxiliary) heating when required. E Emergency heating Activates[...]
-
Page 8
14 14 INST ALLA TION Mount W allplate and Thermostat ■ Remove the wallplate from your thermostat by pressing the release tab on the bottom of the thermostat. (See F igure 2.) ■ P osition w allplate on w all and pull existing wires through large opening. Then level for appearance . Mark holes for plas- tic anchors provided if your existing holes[...]
-
Page 9
16 16 PROGRAMMING Option Menu Y our thermostat has many settings that can be adjusted to fit your system and preferences . ■ Press to enter the Option Menu and to change to the next option selection. ■ Press at any time to return to normal mode . F ahrenheit or Celsius (F ° /C ° ) selection ■ or to change the thermostat display between F ah[...]
-
Page 10
18 18 PROGRAMMING Setting Time and Day ■ T he LCD will show this information when batteries are first installed, or after the Reset button is pressed. T he temperature will update after a few seconds . ■ During time and day setting mode, the temperature and program displays will go blank. ■ Example: Set the T hermostat to the current time of [...]
-
Page 11
20 20 PROGRAMMING Programming Intr oduction Studies conducted by the Department of Energy estimate that setting your thermostat back 10 ° F (6 ° C) for two 8-hour periods during winter can reduce your fuel bill by as much as 33%. By setting your thermostat up 5 ° F (3 ° C) for two 8-hour periods dur - ing summer you can reduce your fuel bill up[...]
-
Page 12
22 22 PROGRAMMING Personal Program Schedule (continued) Cooling Day Prog . 1 Prog . 2 P rog. 3 Prog. 4 Mon. Time T emp T ime T emp Time T emp Time T emp T ues. Time T emp Time T emp T ime Temp Time T emp W ed. Time T emp Time T emp Time T emp Time T emp T hurs. Time T emp Time T emp T ime Temp Time T emp F ri. T ime T emp T ime T emp T ime T emp T [...]
-
Page 13
24 24 PROGRAMMING W eekday/Weekend Pr ogramming Step 1 ■ Slide P ower Switch to ON . ■ Press to select HEA T or COOL to program the corresponding system. (A UT O may be selected, but does not affect the programming steps .) NO TE: If the power switch is in the OFF position, the last system selected will be programmed. Step 2 ■ Press to enter [...]
-
Page 14
26 26 PROGRAMMING 7-Day Programming Step 1 ■ Slide Power Switch to ON . ■ Press to select HEA T or COOL to program the corresponding system. (Auto may be selected, but does not affect the programming steps) Step 2 ■ Press to enter program mode, display shows weekday programs. ■ Press 2 times to reach the Monday program. Step 3 ■ T he Prog[...]
-
Page 15
28 28 PROGRAMMING Everyday Programming Step 1 ■ Slide Power Switch to ON . ■ Press to select HEA T or COOL to program the corresponding system. (Auto may be selected, but does not affect the programming steps) Step 2 ■ Press to enter program mode, display shows weekday programs. ■ Press 9 times to reach the Everyday program. Step 3 ■ T he[...]
-
Page 16
30 30 PROGRAMMING Reviewing Programs Y ou may want to review the programs to confirm that the settings are compatible with your lifestyle . ■ Press to display M - F programs . ■ Press repeatedly to cycle through the 4 programs . Program Options Programmable F an ■ Any time during programming, this will change the fan display between “A UTO?[...]
-
Page 17
32 32 OPERA TION Power Switch T he P ower switch on the front of the thermostat determines the operating mode of the thermostat. Y ou may select ON, OFF or Emergency Heat (EM). When the Power Switch is OFF , all outputs are posi- tively disconnected from the system. NO TE: Anytime you install or remove the thermostat from the wallplate, slide the P[...]
-
Page 18
34 34 OPERA TION OPERA TION[...]
-
Page 19
36 36[...]
-
Page 20
38 38 OPERA TION V acation (Pr ogrammable) Hold T his thermostat can hold a fixed temperature for a selected number of days (up to 30). After the selected number of days , the thermo- stat will return to normal program operation. T his feature allows you to return home to your normal comfort setpoint temperatur es . ■ Press and hold for 2 seconds[...]
-
Page 21
40 40 OPERA TION (continued) Home T oday T his Hunter patented feature allows you to quickly and temporarily override your energy saving program setting on days when you are normally away from home with one k ey press. ■ Press to enter the Home T oday override . T he highest program tempera- ture for today will be selected from your programs in H[...]
-
Page 22
42 42 OPERA TION ■ To review energy usage, press to cycle through T oday , Y esterday , [num- ber] Days , Last 30 days, and T otal. Press again to return to normal mode , or wait 15 seconds for the display to return to normal mode . Y ou can also return to normal mode at any time by pressing RET CLEAR. ■ F or example: T his LCD display shows T [...]
-
Page 23
44 44 OPERA TION SP AN Settings ST AGE 1 Y our thermostat is set at the factory to cycle at 1 ° F (0.5 ° C) above and below the set temperature in Stage 1. (Span = 2.) T his setting has been designed to provide a comfortable room tem- perature under most all conditions . However , if you find your sys- tem cycling too fast or too slow , then the [...]
-
Page 24
46 46 OPERA TION ■ Auto Recovery will be canceled if HOME T ODA Y or HOLD is pressed during the recovery process . The thermostat will enter Home T oday , P ermanent hold or Vacation hold. ■ Auto Recovery will be canceled and change to T emporary Manual Override mode if the setpoint is adjusted during the recovery process . Auto Recovery (conti[...]
-
Page 25
48 48 SAFETY FEA TURES AC Power Monitor ■ This thermostat operates on 24V AC, which is provided by your system’s transformer . If the system loses electricity , then the 24V AC power is lost also . ■ T he 2 AAA batteries provide backup operation of the clock, as well as all programs and settings . ■ If the AC power is lost, then the LCD dis[...]
-
Page 26
50 50 TROUBLESHOOTING SCRAMBLED OR DOUBLE DISPLA Y (numbers over numbers) NO DISPLA Y ENTIRE DISPLA Y DIMS PROGRAM DOES NO T CHANGE AT Y OUR DESIRED SETTING AU TO / F AN DOES NO T TURN ON F AN RUNS CONTINUOUSL Y 1. Remove clear Mylar stick er 1. Check terminal connection. A common (C) wire is required for operation. 2. Check battery connections and[...]
-
Page 27
52 52 WIRING DIAGRAMS HEA T PUMP SYSTEMS NO TE: Common wire connection is REQUIRED. *Add jumper between W2 and E on systems without an E wire . Optional Jumper* THERMOST A T WALLPLA TE TERMINALS G C L O W2 E R Y1 B Emergency Heat Compressor Stage 1 Common Some terminals may not be used Fan Relay Reversing Valve Heat System Monitor Reversing Valve C[...]
-