Hunter Fan 82006 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Hunter Fan 82006, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hunter Fan 82006 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Hunter Fan 82006. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Hunter Fan 82006 should contain:
- informations concerning technical data of Hunter Fan 82006
- name of the manufacturer and a year of construction of the Hunter Fan 82006 item
- rules of operation, control and maintenance of the Hunter Fan 82006 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hunter Fan 82006 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hunter Fan 82006, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hunter Fan service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hunter Fan 82006.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Hunter Fan 82006 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Installation Guide 82006 Orleans Bath Ventilator with Light READ and SAVE THESE INSTR UCTIONS 41947-01 3/29/2006 ENGLISH See page 2 ESp añoL Vea la página 15 05-HF-016-EngS_3.29.06.indd 1 3/29/06 6:40:42 PM[...]

  • Page 2

    2 DISCONNECT ELECTRIC POWER SUPPL Y AND LOCK OUT SERVICE P ANEL BEFORE SERVICING UNIT W arning TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY , OBSERVE THE FOLLOWING: 1. For general ventilating use only . Do not use for ventilat- ing hazardous or explosive materials. 2. T o a void motor bearing damage and noisy/unbalanced impellers, keep dr ywall s[...]

  • Page 3

    E F G H I J M N x4 * * * NO TE: Strain relief cable connector must be installed. Not Inc luded. A B C 95047-07-000 75864-01-000 03242-07-133 95261-01-000 74508-03-133 96641-01-262 x2 75184-01-133 96456-01-444 O 75730-01-444 Extra Screws x2 D K 74933-01-000 L 75882-01-000 3/8” Cable Connector 3 1 T urn off the power source. T ools Needed. (Not sup[...]

  • Page 4

    5 4 7 G 8 F Remove the motor/blower from the housing. 4 H E 3 Remove the pre-loaded screw tip co vers. Remove the wiring cover screw . 6 Back out the pre-loaded screw tips until flush with the side of the housing. Remove the wiring cover . Remove packing material. 41947-01 3/29/2006 41947-01 3/29/2006 05-HF-016-EngS_3.29.06.indd 4 3/29/06 6:40:48 P[...]

  • Page 5

    9 E Pop out the first wiring access slug. Use second if needed. Insert the strain relief (not included) into the housing and secure with washer . Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. New Construction 5 1 0 B C A 1 1 E 5/8 1/2 5/8 1/2 A 1 2 Screw pre-loaded screws into joist or fra[...]

  • Page 6

    A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground A 1 4 Main Switch 1 (AC In) Switch 2 (AC In) *Option Fan & Main Light T ogether *Option A 1 3 Route wires through the strain relief. Connect wires as shown. 0 0 A 1 6 Connect 4” duct and vent to the outside. T ape joints. If ducting does not[...]

  • Page 7

    A 1 9 I Secure the motor by tightening the 2 screws. A2 0 T urn on the power source. 7 Connect wiring harness. DO NOT ALLOW THE MO TOR TO HANG FROM THE WIRING HARNESS. 0 0 0 0 0 0 0 0 A 1 7 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. 0 0 0 0 0 0 0 0 H[...]

  • Page 8

    8 EXISTING F AN B 1 1 E B 1 2 Existing Construction B 1 3 2 1 B 1 4 Route wires through strain relief . Remove an existing fan and check to make sure the open- ing is large enough to accommodate the new motor hous- ing (7 1/4”x 7 3/4”). Move the housing into position abo ve the ceiling Attach existing ducting to duct connector . T ape joints. I[...]

  • Page 9

    9 41947-01 3/29/2006 41947-01 3/29/2006 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground B 1 6 Main Switch 1 (AC In) Switch 2 (AC In) *Option Fan & Main Light T ogether *Option H B 1 8 H B 1 9 B 2 0 I Connect wires as shown. Reinstall the motor by inserting the tabs and pushing up into posit[...]

  • Page 10

    10 Connect wiring harness. DO NOT ALLOW THE FIXTURE TO HANG FROM THE WIRING HARNESS. O N O F F B 2 2 B 2 3 C1 Go to step on page 10 to attach grille . B 2 1 T est the motor . If the motor does not run, check the plug connection. T urn on the power source. Attaching the Grille Remove the thumbscrews. M C 1 J C 2 41947-01 3/29/2006 41947-01 3/29/2006[...]

  • Page 11

    11 41947-01 3/29/2006 41947-01 3/29/2006 NOTE: Remove plastic packaging material from glass dome. Align glass dome and push up. Install fluorescent bulb (Included). C 7 O Screw finial into position. C 5 L C 6 N Attach thumbscrews. WARNING: T o reduce the risk of electrical shock, all 3 thumbscrews MUST be properly installed. M C 4 Align posts 1, 2 [...]

  • Page 12

    12 T rouble Shooting Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extremely quiet. T o confirm that the fan is running, place your hand near the vents to feel the air movement. • T urn power on, replace fuse, or reset breaker . • Check all plug connections to be sure they are secure. • Check the wiring to make[...]

  • Page 13

    13 41947-01 3/29/2006 41947-01 3/29/2006 W arranty Hunter Fan Company Bath Exhaust Fan LIMITED W ARRANTY Hunter Fan Company makes the following limited warr anty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time withi[...]

  • Page 14

    2500 Frisco Avenue, Memphis, T ennessee 38114 Printed in China 41947-01 3/29/2006 14 © 2006 Hunter Fan Company 05-HF-016-EngS_3.29.06.indd 14 3/29/06 6:41:10 PM[...]

  • Page 15

    DESDE Guía de instalación V entilador para baño Orleans 82006 con luz LEA y CONSERVE EST AS INSTRUCCIONES 41947-02 3/29/2006 Esp añol 15 05-HF-016-Sp_3.29.06.indd 15 3/29/06 6:41:58 PM[...]

  • Page 16

    16 41947-02 3/29/2006 41947-02 3/29/2006 DESCONECTE LA ALIMENT ACIÓN ELÉCTRICA Y CIERRE EL P ANEL DE SERVICIO ANTES DE DAR MANTENIMIENTO A LA UNIDAD tc. Retire las cubiertas de las puntas de tornillo precargadas. ADVERTENCIA P A R A R E D U C I R E L R I E S G O D E D E S C A R G A E L É C T R I C A O LE SI ON ES , O B S E R V E L O S I G U I E [...]

  • Page 17

    E F G H I J M N x4 * * * NO T A: Debe estar instalado el manguito de alivio de tensión del cable. No incluido. A B C 95047-07-000 75864-01-000 03242-07-133 95261-01-000 74508-03-133 96641-01-262 x2 75184-01-133 96456-01-444 O 75730-01-444 x2 D K 74933-01-000 L 75882-01-000 Conector de cable de 3/8” T ornillos adicionales 17 1 Apague la fuente de[...]

  • Page 18

    5 4 7 G 8 F 18 H E 3 Retire las cubiertas de las puntas de tornillo precargadas. Retire el tornillo de la cubierta del cableado. 6 Retire las puntas de tornillo precargadas hasta que estén a nivel con el lado del alojamiento. Retire la cubierta del cableado. Retire el material de embalaje. Retire el motor/soplador del alojamiento. 41947-02 3/29/20[...]

  • Page 19

    9 E Retire el primer tapón metálico de acceso del cableado. Utilice el segundo si es necesario. Inserte el manguito de alivio de tensión (no se inc luye) en la caja y sujételo firmemente con una arandela. Construcción nueva 19 1 0 B C A 1 1 E 5/8 1/2 5/8 1/2 A 1 2 Instale los tornillos precargados en la viga o el marco. Ubique la correcta marc[...]

  • Page 20

    A Motor del ventilador Luz Verde Negro Interruptor 2 (CA) Negro Interruptor principal 1 (CA) Blanco Negro Luz Blanco Blanco Cobre desnudo Tierra A 1 4 *Opción Ventilador y luz principal juntos *Opción Negro 3 pasadores 3 clavijas 2 pasadores 2 clavijas A 1 3 Tienda los cables a través del manguito de alivio de tension. Conecte los alambres como [...]

  • Page 21

    A 1 9 I Asegure el motor apretando los 2 tornillos. A2 0 Encienda la fuente de alimentación. 21 Conecte el mazo de cables. NO PERMIT A QUE EL MOTOR CUELGUE DEL MAZO DE CABLES. 0 0 0 0 0 0 0 0 A 1 7 V uelva a instalar el motor introduciendo las pestañas y levantando a su posición. Asegúrese que los alambres no se pellizquen entre el motor y el a[...]

  • Page 22

    22 VENTILADOR EXISTENTE B 1 1 E B 1 2 Construcción existente B 1 3 2 1 B 1 4 Tienda los cables a través del manguito de alivio de tension. Retire el ventilador existente y asegúrese que la abertura sea suficientemente grande para acomodar el alojamiento del motor nuevo (7 1/4”x 7 3/4”). Mueva el alojamiento a su posición encima del techo. C[...]

  • Page 23

    23 41947-02 3/29/2006 41947-02 3/29/2006 B 2 0 I A Motor del ventilador Luz Verde Negro Interruptor 2 (CA) Negro Interruptor principal 1 (CA) Blanco Negro Luz Blanco Blanco Cobre desnudo Tierra B 1 6 *Opción Ventilador y luz principal juntos *Opción Negro 3 pasadores 3 clavijas 2 pasadores 2 clavijas H B 1 8 H B 1 9 Conecte los alambres como se m[...]

  • Page 24

    24 O N O F F B 2 2 B 2 3 C1 Vaya al paso en la página 24 para fijar la rejilla. B 2 1 Pruebe el motor . Si el motor no funciona, verifique la conexión del enchufe. Encienda la fuente de alimentación. Fijación de la rejilla Retire los tornillos de mano. Conecte el mazo de cables. NO PERMIT A QUE EL ARTEF ACTO DE ILUMINACIÓN CUELGUE DEL MAZO DE [...]

  • Page 25

    25 41947-02 3/29/2006 41947-02 3/29/2006 NOT A: Retirar material plástico de empaque la pantalla. Alinee la pantalla y levante. Instale la lámpara fluorescente (incluida). C 7 O Enrosque la cubierta ornamental. C 5 L C 6 N Instale los tornillos de mano. ADVERTENCIA: P ara reducir el riesgo de descarga eléctrica, los 3 tornillos de mano DEBEN ins[...]

  • Page 26

    26 41947-02 3/29/2006 41947-02 3/29/2006 Solución de problemas Problema: El ventilador no está operando. Solución: • Los ventiladores de baño Hunter son muy silenciosos. Para confirmar que el ventilador está funcionando, coloque su mano cerca de los conductos de ventilación para sentir el movimiento del aire. • Encienda la alimentación [...]

  • Page 27

    27 41947-02 3/29/2006 41947-02 3/29/2006 Garantía Hunter Fan Company Extractor de aire para baño GARANTÍA LIMIT ADA Hun ter Fan Co mpan y e stab lec e l a si gui ent e ga ran tía li mita da al u sua rio o c omp rad or orig ina l de es te Extr act or de air e pa ra bañ o H unte r: Si alguna pieza de su Extractor de aire para baño Hunter (con e[...]

  • Page 28

    2500 Frisco Avenue, Memphis, T ennessee 38114 Impreso en China 41947-02 3/29/2006 © 2006 Hunter Fan Company 05-HF-016-Sp_3.29.06.indd 28 3/29/06 6:42:26 PM[...]