Hunter Fan 90063 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Hunter Fan 90063, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hunter Fan 90063 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Hunter Fan 90063. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Hunter Fan 90063 should contain:
- informations concerning technical data of Hunter Fan 90063
- name of the manufacturer and a year of construction of the Hunter Fan 90063 item
- rules of operation, control and maintenance of the Hunter Fan 90063 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hunter Fan 90063 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hunter Fan 90063, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hunter Fan service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hunter Fan 90063.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Hunter Fan 90063 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    41722-01 02/13/2013 1 Bath V entilator with Light and Night Light Owner ’ s Manual Ellipse 41722-01 02/13/13 ©2013 Hunter Fan Co. Model 90063/90064 English Français Page 21[...]

  • Page 2

    41722-01 02/13/2013 2 DISCONNECT ELECTRIC POWER SUPPL Y AND LOCK OUT SER VICE P ANEL BEFORE SER VICING UNIT W ARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJUR Y T O PERSONS, OBSERVE THE FOLLOWING: 1. For general ventilating use only . Do not use to exhaust hazard- ous or explosive materials and vapors. 2. T o avoid motor bearing damage a[...]

  • Page 3

    41722-01 02/13/2013 3 D E F G H I 95044-01-000 95022-01-000 75190-01-000 03242-07-133 95492-01-000 74508-03-133 L 95510-02-000 J 74534-01-000 K 95366-01/02-000 M 75184-01-232 x5 * * A B C Extra Screws x2 I 3/8” Cable Connector x2 OF F 30 OF F 30 OF F 20 30 OF F 30 OF F 30 20 1 2 E I T urn off the power source. T ools Needed. (Not supplied) Estima[...]

  • Page 4

    41722-01 02/13/2013 4 5 7 G 8 F H E 3 6 4 Remove the motor/blower from the housing. Remove the pre-loaded screw tip covers. Remove the wiring cover screw . Back out the pre-loaded screw tips until ush with the side of the housing. Remove the wiring cover . Remove packing material.[...]

  • Page 5

    41722-01 02/13/2013 5 E 9 B C 10 E A1 1 5/8 1/2 5/8 1/2 A1 2 Pop out the rst wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer . Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. New Construction – attaching to joist Choose Inst[...]

  • Page 6

    41722-01 02/13/2013 6 A1 3 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black Red Red White Black Black White White Bare Copper Ground A14 Night Light Night Light Switch 1 (AC In) Main Switch 1 (AC In) Switch 2 (AC In) *Option Fan & Main Light To gether *Option A15 F 1 2 F • A16 G Pull wires through the strain relief. Connect wires as show[...]

  • Page 7

    41722-01 02/13/2013 7 0 A1 7 H A18 I A20 A19 H A21 O N O F F A22 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Secure the motor by tightening the 2 screws. T est the motor . If the motor does not run, check the plug connection. T urn on the power source[...]

  • Page 8

    41722-01 02/13/2013 8 A2 3 E1 Go to step on page 18 to attach grille . B1 1 D E 5/8 1/2 5/8 1/2 B12 E B1 3 1/8" Bit B14 Slide the mounting rails into brackets. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Mark position of screws by using holes as a template. Drill a hole in the cente[...]

  • Page 9

    41722-01 02/13/2013 9 B17 B1 5 B1 6 B18 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black Red Red White Black Black White White Bare Copper Ground B19 Night Light Night Light Switch 1 (AC In) Main Switch 1 (AC In) Switch 2 (AC In) *Option Fan & Main Light T ogether *Option Pull wires through the strain relief. Tighten screws. Attach the rai[...]

  • Page 10

    41722-01 02/13/2013 10 B2 0 F 1 2 F • B21 G B2 2 B2 3 H B2 4 H B2 5 I Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Tighten the wiring cover plate screw . Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the mo[...]

  • Page 11

    41722-01 02/13/2013 11 B2 8 E1 Go to step on page 18 to attach grille . B26 O N O F F B27 EXISTING FA N C1 1 NO EXISTING FA N T est the motor . If the motor does not run, check the plug connection. T urn on the power source. Existing Construction – accessible from above Remove an existing fan and check to make sure the opening is large enough to [...]

  • Page 12

    41722-01 02/13/2013 12 9” 9.75” C12 D E 5/8 1/2 5/8 1/2 C13 C14 C15 1/8" Bit C1 6 Cut out an opening for the housing. Slide the mounting rails into brackets. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Mark position of screws by using holes as a template. Drill a hole in the cen[...]

  • Page 13

    41722-01 02/13/2013 13 C17 C18 C19 C20 C21 Attach the rails onto the screws. Tighten screws. Connect 4” duct and vent to the outside. T ape joints. If ducting does not t securely , an adapter may need to be purchased. Pull wires through the strain relief. Tighten the strain relief screws.[...]

  • Page 14

    41722-01 02/13/2013 14 C2 3 F 1 2 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black Red Red White Black Black White White Bare Copper Ground C22 Night Light Night Light Switch 1 (AC In) Main Switch 1 (AC In) Switch 2 (AC In) *Option Fan & Main Light T ogether *Option • C24 G C2 5 H C2 6 H Connect wires as shown. Install the wiring cover p[...]

  • Page 15

    41722-01 02/13/2013 15 C3 0 E1 Go to step on page 18 to attach grille . C2 7 I C2 8 O N O F F C2 9 EXISTING FA N D1 1 E D12 Secure the motor by tightening the 2 screws. T est the motor . If the motor does not run, check the plug connection. T urn on the power source. Existing Construction – accessible only from below Remove an existing fan and ch[...]

  • Page 16

    41722-01 02/13/2013 16 D13 2 1 D14 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black Red Red White Black Black White White Bare Copper Ground D16 Night Light Night Light Switch 1 (AC In) Main Switch 1 (AC In) Switch 2 (AC In) *Option Fan & Main Light T ogether *Option Connect wires as shown. E D15 Pull wires through strain relief. Attach ex[...]

  • Page 17

    41722-01 02/13/2013 17 • D18 G Tighten the wiring cover plate screw . D17 F 1 2 Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. D19 H D20 H I D21 D2 2 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor an[...]

  • Page 18

    41722-01 02/13/2013 18 M H E1 O N O F F D2 3 D2 4 E1 Go to step on page 18 to attach grille . E4 J E3 H L E2 N Attaching the Grille T est the motor . If the motor does not run, check the plug connection. Position the strain relief bracket between the plugs as shown, and screw into place. Remove the thumbscrews. Remove glass. Connect wiring harness.[...]

  • Page 19

    41722-01 02/13/2013 19 E7 N E5 M Align glass and push up. T rouble Shooting Problem: Fan does not come on. Solution:  •  HunterFanBathV entilatorsareextremelyquiet.T o conrmthatthefanisrunning,placeyourhandnear the vents to feel the air movement.  • T urn?[...]

  • Page 20

    41722-01 02/13/2013 20 7130 Goodlett Farms Pkwy ., Suite 400, Memphis, T ennessee 38016 Printed in China W arranty Hunter Fan Company Bath Exhaust Fan LIMITED W ARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: IfanypartofyourHunterbathexh[...]

  • Page 21

    V entilateur de salle de bains avec lumière et veilleuse Guide du pr opriétaire Ellipse 41722-05 02/13/13 ©2013 Hunter Fan Co. Modèle 90063/90064 Français[...]

  • Page 22

    42916-05 02/13/2013 22 DÉCONNECTER L ’ALIMENT A TION ÉLECTRIQUE ET VERROUILLER LE P ANNEAU DE SER VICE A V ANT DE F AIRE L ’ENTRETIEN DE L ’UNITÉ. MISE EN GARDE POUR RÉDUIRE LE RISQUE D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURES, VEUILLEZ SUIVRE LES DIRECTIVES SUIV ANTES : 1. Uniquement pour un usage général de ventilation. Ne[...]

  • Page 23

    42916-05 02/13/2013 23 D E F G H I 95044-01-000 95022-01-000 75190-01-000 03242-07-133 95492-01-000 74508-03-133 L 95510-02-000 J 74534-01-000 K 95366-01/02-000 M 75184-01-232 x5 * * A B C Extra Screws x2 I 3/8” Cable Connector x2 OF F 30 OF F 30 OF F 20 30 OF F 30 OF F 30 20 1 2 E I Couper le courant. Outils nécessaires. (Non fournis) T emps es[...]

  • Page 24

    42916-05 02/13/2013 24 5 7 G 8 F H E 3 6 4 Retirer le moteur/souffleur du boîtier . Retirer les capuchons du bout des vis pré-installées. Retirer la vis du couvercle du câblage. Dévisser les vis pré-installées jusqu’à ce que leur bout affleure le côté du boîtier . Retirer le couvercle du câblage. Retirer les matériaux d’emballage.[...]

  • Page 25

    42916-05 02/13/2013 25 E 9 B C 10 E A1 1 5/8 1/2 5/8 1/2 A1 2 Défoncer le première pastille d’accès. En utiliser une seconde si nécessaire. Introduire le raccord (non compris) dans le boîtier et le fixer avec aune rondelle. Placer la bonne marque de hauteur sur le bord inférieur de la solive selon l’épaisseur de votre plaque de gypse. No[...]

  • Page 26

    42916-05 02/13/2013 26 A1 3 A Noir Lumière Noir Blanc Blanc A14 *Option Rouge Ve illeuse Ve illeuse Rouge Interrupteur 1 (entrée CA) Moteur du ventilateur Lumière Ve rt Blanc Cuivre nu Prise de terre Interrupteur principal 1 (entrée CA) Interrupteur principal 2 (entrée CA) *Option ventilateur et lumière principale ensemble 3 broches 2 broches[...]

  • Page 27

    42916-05 02/13/2013 27 0 A1 7 H A18 I A20 A19 H A21 M A R CH E A R R ÊT A22 Reposer le moteur en insérant les languettes et en le poussant vers le haut en place. Assurez-vous que les fils n’ont pas été pincés entre le moteur et le boîtier . Fixer le moteur en serrant les deux vis. Essayer le moteur . Si le moteur ne fonctionne pas, vérifie[...]

  • Page 28

    42916-05 02/13/2013 28 A2 3 E1 A ller à l’étape à la page 38 pour fixer la grille . B1 1 D E 5/8 1/2 5/8 1/2 B12 E B1 3 Mèche de 1/8 po (3,2 mm) B14 Faire glisser les glissières de fixation dans les supports. Placer la bonne marque de profondeur sur le bord inférieur de la solive selon l’épaisseur de votre plaque de gypse. Marquer la pos[...]

  • Page 29

    42916-05 02/13/2013 29 B17 B1 5 B1 6 B18 A Noir Lumière Noir Blanc Blanc B19 *Option Rouge Ve illeuse Ve illeuse Rouge Interrupteur 1 (entrée CA) Moteur du ventilateur Lumière Ve rt Blanc Cuivre nu Prise de terre Interrupteur principal 1 (entrée CA) Interrupteur principal 2 (entrée CA) *Option ventilateur et lumière principale ensemble 3 broc[...]

  • Page 30

    42916-05 02/13/2013 30 B2 0 F 1 2 F • B21 G B2 2 B2 3 H B2 4 H B2 5 I Installer la plaque de couvercle du câblage. Assurez-vous que toutes les connexions de câblage sont dans la boîte ou derrière la plaque de couvercle du câblage. Resserrer la vis de la plaque du couvercle de câblage. Reposer le moteur en insérant les languettes et en le p[...]

  • Page 31

    42916-05 02/13/2013 31 B2 8 E1 A ller à l’étape à la page 38 pour fixer la grille . B26 M A R CH E A R R ÊT B27 VENTILA TEUR EXIST ANT C1 1 VENTILA TEUR NON EXIST ANT Essayer le moteur . Si le moteur ne fonctionne pas, vérifier la connexion enfichable. Remettre le courant. Construction existante – accessible du dessus Enlever un ventilateu[...]

  • Page 32

    42916-05 02/13/2013 32 9” 9.75” C12 D E 5/8 1/2 5/8 1/2 C13 C14 C15 Mèche de 1/8 po (3,2 mm) C1 6 Découper une ouverture pour le boîtier . Faire glisser les glissières de fixation dans les supports. Placer la bonne marque de profondeur sur le bord inférieur de la solive selon l’épaisseur de votre plaque de gypse. Marquer la position des[...]

  • Page 33

    42916-05 02/13/2013 33 C17 C18 C19 C20 C21 Fixer les glissières sur les vis. Visser les vis. Raccorder la gaine de 4 po et l’évent à l’extérieur . Jointer avec du ruban. Si la gaine n’est pas de la bonne dimension, vous pourriez devoir acheter un adaptateur . Passer les fils par le raccord. Serrer les vis du raccord.[...]

  • Page 34

    42916-05 02/13/2013 34 C2 3 F 1 2 A Noir Lumière Noir Blanc Blanc C22 *Option Rouge Ve illeuse Ve illeuse Rouge Interrupteur 1 (entrée CA) Moteur du ventilateur Lumière Ve rt Blanc Cuivre nu Prise de terre Interrupteur principal 1 (entrée CA) Interrupteur principal 2 (entrée CA) *Option ventilateur et lumière principale ensemble 3 broches 2 b[...]

  • Page 35

    42916-05 02/13/2013 35 C3 0 E1 A ller à l’étape à la page 38 pour fixer la grille . C2 7 I C2 8 M A R CH E A R R ÊT C29 VENTILA TEUR EXIST ANT D1 1 E D12 Fixer le moteur en serrant les deux vis. Essayer le moteur . Si le moteur ne fonctionne pas, vérifier la connexion enfichable. Remettre le courant. Construction existante – accessible uni[...]

  • Page 36

    42916-05 02/13/2013 36 D13 2 1 D14 A Noir Lumière Noir Blanc Blanc D16 *Option Rouge Ve illeuse Ve illeuse Rouge Interrupteur 1 (entrée CA) Moteur du ventilateur Lumière Ve rt Blanc Cuivre nu Prise de terre Interrupteur principal 1 (entrée CA) Interrupteur principal 2 (entrée CA) *Option ventilateur et lumière principale ensemble 3 broches 2 [...]

  • Page 37

    42916-05 02/13/2013 37 • D18 G Resserrer la vis de la plaque du couvercle de câblage. D17 F 1 2 Installer la plaque de couvercle du câblage. Assurez-vous que toutes les connexions de câblage sont dans la boîte ou derrière la plaque de couvercle du câblage. D19 H D20 H I D21 D2 2 Reposer le moteur en insérant les languettes et en le poussan[...]

  • Page 38

    42916-05 02/13/2013 38 M A R CH E A R R ÊT D23 D2 4 E1 A ller à l’étape à la page 38 pour fixer la grille . E4 J Fixation de la grille Essayer le moteur . Si le moteur ne fonctionne pas, vérifier la connexion enfichable. Placer le serre-câbles entre les fiches montrées et le visser en place. Retirer les vis à serrage à main. Retirer le v[...]

  • Page 39

    42916-05 02/13/2013 39 Aligner le verre et pousser vers le haut. Dépannage Problème : Le ventilateur ne fonctionne pas. Solution :  • Les ventilateurs de salle de bain Hunter sont très silencieux. Pour vérifier que le ventilateur fonctionne, placez votre main près des évents pour sentir le mouvement de l’a[...]

  • Page 40

    42916-05 02/13/2013 40 7130 Goodlett Farms Pkwy ., Suite 400, Memphis, T ennessee 38016 Imprimé en Chine © 2013 Hunter Fan Company Garantie Hunter Fan Company V entilateur de salle de bain GARANTIE LIMITÉE La société Hunter Fan Company , Inc. offre la garantie limitée suivante à l’usager initial ou au client acheteur de ce ventilateur de s[...]