A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Hunter Fan TypeB, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hunter Fan TypeB one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Hunter Fan TypeB. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Hunter Fan TypeB should contain:
- informations concerning technical data of Hunter Fan TypeB
- name of the manufacturer and a year of construction of the Hunter Fan TypeB item
- rules of operation, control and maintenance of the Hunter Fan TypeB item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hunter Fan TypeB alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hunter Fan TypeB, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hunter Fan service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hunter Fan TypeB.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Hunter Fan TypeB item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
T ype T ,G,B Models T ype T ,G,B Models T ype T ,G,B Models Form# 41847-01 20100528 ©2010 Hunter Fan Co. For Y our Records and W arranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. __________________________________________ Model Name __________________________________________ Model No. _____________[...]
-
Page 2
2 41847-01 • 05/28/10 • Hunte r Fan Company T ab le Of Contents Preparing the F an Site . . . . . . . . . . . . . . . . . 3 1 • G e t t i n g R e a d y ...................... 6 2 • Installing the Ceiling P late . . . . . . . . . . 7 3 • Ass embling and Hanging the Fan . . . 8 4 • Wiring the Fan . . . . . . . . . . . . . . . . . . . . . [...]
-
Page 3
3 41847-01 • 05/28/10 • Hunte r Fan Company 7’ Minimum Blades to Floor 8’ Minimum Ceiling Height 30” From W all or Nearest Obstruction St ep 1 - Ch oo se th e F an Sit e Proper ceiling fan loc ation and at tachment to the building struct ure ar e ess ent ial for safety, r eliable operation, maximum efficiency, and e nergy savings . Choos [...]
-
Page 4
4 41847-01 • 05/28/10 • Hunte r Fan Company P r e p a r i n g t h e Fa n S i t e ( c o n t i n u e d ) CAUT ION: All wiring must b e in accordance wi th national and local electrical cod es and ANSI/NFP A 70. If you are unfamiliar with wiring, use a qualified electrician. Steps 2 – 3 Step 4 Step 5 St ep 2 - Cut th e Ce ilin g Hole 2-1. Locat[...]
-
Page 5
5 41847-01 • 05/28/10 • Hunte r Fan Company I n s t a l l e r ’ s C h o i c e a n d O p t i o n a l A c c e s s o r i e s Understan ding Mountin g and Instal ler’ s C hoic e ® Hunte r ’ s pate nted 3-position mounting syst em provides you maximum installation flexibility and ease . Y ou can install your Hunter fan in one of three wa ys [...]
-
Page 6
6 41847-01 • 05/28/10 • Hunte r Fan Company T o install a ceiling fan, be sure you can do the following: • Lo cate the ce iling joist or other suitable suppor t in ceiling . • Drill hol es for and install woo d screws. • Identif y and connec t electrical wires. • Lift 40 p ounds. If you need help installing the fan, your Hunter fan deal[...]
-
Page 7
7 41847-01 • 05/28/10 • Hunte r Fan Company CAU TION: T o a void pos sible electrical sho ck, b efore installing your fan, disconnect the p ower by t urning off the circuit br eakers t o the outlet box and asso ciated wall switc h loc ation. If you cannot lock the circuit br eakers in the off position, securely fasten a promine nt warning dev[...]
-
Page 8
8 41847-01 • 05/28/10 • Hunte r Fan Company Steps 3-5 – 3-6 Low Profile Screw Low Profile W a sher Steps 3-2 – 3-3 Downrod Canopy Canopy T rim Ring Sets crew W ARNIN G: Fan ma y fall if not ass embled a s directed in these installation ins tructions. 3-1. Unbundle the wires from t he fan. For Standard or Angle d mounting: 3-2. T o ass emb[...]
-
Page 9
9 41847-01 • 05/28/10 • Hunte r Fan Company All wiring must b e in accorda nce with national and lo cal ele c trical code s and ANSI/NFP A 70. If you are unfam iliar with wiring , use a qualifie d elec trician. W all switches are not included. Selec t an acceptable general-use switch in accordanc e with nat ional and lo cal electrical co des .[...]
-
Page 10
10 41847-01 • 05/28/10 • Hunte r Fan Company 5-1. Holding the c anopy , rais e the fan off the hook . 5-2. Align the slots in the canopy with the tabs on the ceiling plat e. 5-3. Rais e the canopy over the ceiling plat e. Rotate the canopy clockwise until the tabs on the ceiling plate t otally engage with the slots in the canopy . 5-4. Partial[...]
-
Page 11
11 41847-01 • 05/28/10 • Hunte r Fan Company Step 6-1 (Deta il) Grommet Blade Ass embly Screws Use with grommet Use without grommet Hunte r fans us e several styl es of fan blad e irons (brack ets that hold the blade to the fan). 6-1. Y our f an may inc lude blad e grommets. If your f an has grommets, insert them by hand int o the holes on the [...]
-
Page 12
12 41847-01 • 05/28/10 • Hunte r Fan Company Y our Hunter fan comes with an int egrated light fixt ure assembly and an optional swit ch housing cap and plug b utton. i s feat ure gives you the option of installing the fan with OR without t he included light fixtur e . e steps below direct you whether or not you ar e installing a light ?[...]
-
Page 13
13 41847-01 • 05/28/10 • Hunte r Fan Company Lower Swit ch Housing Plug Connector Housing Ass embly Screw Plug Connector Detail Steps 7-6 – 7-7 7-6. T o attach the lower swit ch housing , connect the upp er plug connector from the motor to t he lower plug connec tor in the lower switc h housing as sembly . Note: Both plug conne ctors are po l[...]
-
Page 14
14 41847-01 • 05/28/10 • Hunte r Fan Company Installing the Lig ht Fixture 7-9. Remove the swit ch housing cap and plug button from the lower switc h housing . 7-10. Push the wir es from the light kit t hrough the hole in the cent er of the lower swit ch housing . 7-11. Screw the threaded rod of the light fixt ure into the lower switc h housin[...]
-
Page 15
15 41847-01 • 05/28/10 • Hunte r Fan Company 7 • C o m p l e t i n g Yo u r I n s t a l l a t i o n W i t h o r W i t h o u t a B o w l L i g h t F i x t u r e ( C o n t i n u e d ) Installing the Gl ass Bowl 7-16. First install B10 candelabra bulbs (60 Watt Maximum) into the sockets. 7-17. Attach the extra pull chain (included) to the fan pu[...]
-
Page 16
16 41847-01 • 05/28/10 • Hunte r Fan Company In warm weather , us e downward air flow patt ern In cold weather , us e upward air flow pattern 8-1. T urn on elec trical power to the fan. 8-2. e fan pull chain contr ols power to the fan. e pull chain has four settings in se quence: High, Medium, Low , and Off. • Pull the c hain slowly [...]
-
Page 17
17 41847-01 • 05/28/10 • Hunte r Fan Company Problem: No thing happens; f an do es no t move. 1. T urn p ower on, re place fus e, or reset breaker . 2. Loos en canopy , check all connections according t o the wiring the fan sec tion. 3. Check the plug connection in the switch housing. 4. Push motor r eversing switc h firmly left or right to en[...]