Hunter 47550 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Hunter 47550, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hunter 47550 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Hunter 47550. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Hunter 47550 should contain:
- informations concerning technical data of Hunter 47550
- name of the manufacturer and a year of construction of the Hunter 47550 item
- rules of operation, control and maintenance of the Hunter 47550 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hunter 47550 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hunter 47550, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hunter service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hunter 47550.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Hunter 47550 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Owner Õ s Manua l Model 4 7 550 SINCE 1 8 8 6 ® A UT O SA VER 550 5: 7 2 2 2 3[...]

  • Page 2

    Ask Y our Local R etailer for Other Quality Pr oducts fr om Hunter T o locate your near est Hunter Dealer , call 1-800-4HUNTER, or visit The Hunter Fan Company website: www .hunterfan.com Fans Air Purifiers Humidifiers[...]

  • Page 3

    Introduction Model Information: Model Numbe r ____________________________________ Serial Numbe r _____________________________________ Date Purchased____________________________________ Where Pur chased ___________________________________________________________ CONGRA TULA TIONS! Y our new Hunter electronic thermostat will pr ovide years of relia[...]

  • Page 4

    T able of Contents Read This Before Installing Thermostat 6 Features 8 What Y ou Need 10 Remove Old Thermostat 10 Wire Labeling 11 Mount W allplate and Thermostat 12 Selector Switches 14 Setting Time and Day 16 Auto Programming 17 Personal Program Schedule 18 Manual Programming 19 W eekday / W eekend Programming 19 7-Day Programming 21 Reviewing Pr[...]

  • Page 5

    OPERA TIONS ( continued) SAFETY FEA TURES TROUBLESHOOTING WIRING DIAGRAMS T emporary Manual Override 24 Permanent Manual (V acation) Override 25 Auto Season Changeover 26 Home T oday 26 Energy Monitor 28 Filter Monitor 29 Auto Recovery 30 Keyboard Lock 31 Backlighting 31 Low Battery W arning 32 Error Mode 33 Auto Cut-Off 33 Problems & Solutions[...]

  • Page 6

    IMPORT ANT 1 Read the entire installation section of this Owner’ s Manual thoroughly befor e you begin to install or operate your Hunter Thermostat. REMOVE THE MYLAR LABEL FROM THE LCD DISPLA Y WINDOW . INST ALLA TION 2 All installation is normally performed at your thermostat. ARMCHAIR PROGRAMMING 3 Y ou can program your thermostat befor e insta[...]

  • Page 7

    Read This Before Installing Thermostat (continued) POWER F AILURE 7 W henever the main power is interrupted or fails, the battery power retains the pr ograms and current time. AUTO RECOVER Y 8 Y our thermostat is set fr om the factory to gradually recover the room temperatur e from an ener gy saving program to your comfort program. Ther efore, the [...]

  • Page 8

    Features HOME TODA Y : Overrides energy- saving program temperatur es while you are at home for the day . ENERGY : Measures and displays heating and cooling system operating time for T oday , Y esterday , This W eek, Last W eek, or T otal. By monitoring your energy usage, you can program the thermostat to optimize energy savings. T emperature Keys:[...]

  • Page 9

    Provides permanent temperature setting by overriding stored programs. It also r eturns the thermostat to current program contr ol from manual override or Home T oday mode. For entering minute of day . Enters Program Mode for reviewing and changing weekday , weekend, or daily programs. Selects the day or days to review or change in Program Mode. Ret[...]

  • Page 10

    10-11 INST ALLA TION This thermostat includes two #8 slotted screws and two wall anchors for mounting. T o install your thermostat, you should have the following tools and materials. ■ Slotted Screwdriver(s) ■ Phillips Screwdriver ■ Hammer ■ Electric drill and 3/16" bit ■ T wo 1.5 V (AA) size alkaline batteries What Y ou Need CAUTION[...]

  • Page 11

    ■ Each wire coming from the wall to the existing thermostat is connected to a terminal point on that thermostat. Each of these terminal points is usually marked with a code letter as shown in T able A on this page. ■ The number of wir es in your system can be as few as two (for heat only systems), as many as eight, or any number in between. If [...]

  • Page 12

    ■ Remove the wallplate from your thermostat by pr essing the release tab on the bottom of the thermostat. (See Figur e 2.) ■ Position wallplate on wall and pull existing wires thr ough large opening. Then level for appearance. Mark holes for plastic anchors provided if your existing holes do not line up with those on the Hunter wallplate. ■ D[...]

  • Page 13

    ■ Match and connect the labeled wires to the appr opriate coded terminal screws on the mounting plate. (See Figure 4, 5.) Ignor e any wires which may be pr esent, but which were not connected to the old thermostat. ■ Be sure to tighten the terminal scr ews securely , otherwise a loose wire could cause operational pr oblems with your system or t[...]

  • Page 14

    In order for this Hunter thermostat to contr ol your system, the system type must be specified by selector switches on the printed circuit boar d inside the thermostat. There ar e also other selector switches that allow you to customize the features to suit your needs. NOTE: When changing these features after installation, move the HEA T / COOL sel[...]

  • Page 15

    Switch Setting Switch Function Alternate Standard SW 5 F° / C° Celsius Fahrenheit SW 6 12 Hr . / 24 Hr . 24 Hour 12 Hour SW 7 Span +2°F / –1°F +1°F / –1°F SW 8 Auto Recovery Disable Enable T able B Feature Selector Switches: ■ F° / C° selector (Fahrenheit / Centigrade) – Switch 5 Y our thermostat is set for F° mode from the factory[...]

  • Page 16

    16-17 PROGRAMMING Remove the mylar label covering the LCD display window before operating thermostat. Setting Time and Day HOUR MIN DA Y RETURN EXAMPLE: Set the thermostat to the current time of 9:43 a.m. on Saturday . Refer to Figure at right. ■ During time and day setting mode, the temperatur e and program displays will go blank. ■ Pr ess and[...]

  • Page 17

    Studies conducted by the Department of Energy estimate that setting your thermostat back 10°F (6°C) for two 8-hour periods during winter can reduce your fuel bill by as much as 33%. By setting your thermostat up 5°F (3°C) for two 8-hour periods during summer you can reduce your fuel bill up to 25%. Y our thermostat is capable of holding up to 4[...]

  • Page 18

    18-19 PROGRAMMING Personal Program Schedule Day Program 1 Program 2 Program 3 Program 4 Mon. Time Time Time Time T emp T emp T emp T emp T ues. Time Time Time Time T emp T emp T emp T emp W ed. Time Time Time Time T emp T emp T emp T emp Thurs. Time Time Time Time T emp T emp T emp T emp Fri. Time Time Time Time T emp T emp T emp T emp Sat. Time Ti[...]

  • Page 19

    ■ Y our thermostat can be programmed for weekdays and weekends, or have unique programs for all 7 days. Use W eekday/W eekend Programming below or 7-day Programming on page 21 to enter or revise pr ograms to match your Personal Program Schedule. The same steps ar e used when entering programs for the first time, or r evising programs enter ed dur[...]

  • Page 20

    20-21 PROGRAMMING W eekday/W eekend Pr ogramming (cont.) Step 3 Step 5 ■ Press to change to weekend pr ograms. ■ Repeat Steps 3 and 4 to complete the weekend programs. Step 6 ■ If you desir e only weekend and weekday programs, pr ess to return to normal mode. ■ After 15 seconds, the thermostat will r eturn to normal mode automatically . RET[...]

  • Page 21

    Step 2 ■ Pr ess to enter program mode, display shows weekday programs. ■ Pr ess 2 times to reach the Monday pr ogram. PROG Step 3 PROG DA Y Step 5 ■ Press to change to the next day’ s programs. ■ Repeat Steps 3 and 4 to complete the selected day’ s programs. ■ Continue repeating Steps 3, 4 and 5 to pr ogram all 7 days of the week. Ste[...]

  • Page 22

    Y ou may want to review the pr ograms to confirm that the settings are compatible with your lifestyle. 22-23 PROGRAMMING Reviewing Programs W eekday Programs ■ Pr ess to display M – F programs. ■ Press r epeatedly to cycle through the 4 pr ograms. PROG W eekend Programs ■ Press repeatedly to cycle through the 4 pr ograms. PROG ■ Press to [...]

  • Page 23

    Daily Programs ■ Press to display M – F programs. NOTE: Time and T emperature display will be blank when at least one weekday program is dif ferent. ■ Press r epeatedly to cycle through the 4 pr ograms. PROG PROG ■ Press to change to Sa – Su. Again, if the display is blank, one of the weekend programs is dif ferent. ■ Pr ess again to ch[...]

  • Page 24

    The System Selector switch on the front of the thermostat determines the operating mode of the thermostat. Y ou may select COOL, OFF , HEA T , AUTO. In order to take full advantage of this thermostat’ s features, we recommend using the AUTO mode. Refer to the Auto Season Changeover information on page 26. NOTE: Anytime you install or remove the t[...]

  • Page 25

    T o end the T emporary Manual Override: NOTE: The Auto Season Changeover feature will not operate while the thermostat is in T emporar y Manual Override. Refer to the Auto Season Changeover feature on page 26 for more information. NOTE: If the thermostat has not been programmed, then a T emporar y Override becomes a Permanent Override. See the next[...]

  • Page 26

    When the System Selector is in AUTO position, the thermostat will automatically change between Heating and Cooling systems, depending on your program. W e recommend keeping your programmed heating and cooling temperatur es at least 4°F (2°C) apart to allow the Auto Season Changeover to occur when the appropriate temperatur e span has been reached[...]

  • Page 27

    ■ Press to exit Home T oday mode before the schedule ending time. “HOME” is no longer displayed on the LCD screen, and the thermostat returns to the current pr ogram. HOLD CLEAR HOME TODA Y HOME TODA Y ■ If Home T oday is already active, you may similarly extend it to the first program of the next day by pr essing the key again after the st[...]

  • Page 28

    72 . 7I . 70 . 28-29 OPERA TION Energy Monitor ENERGY ENERGY ■ Press and hold for 3 seconds to reset the Ener gy Monitor’ s counters. The display will blink, and all counters will be cleared to zer o. NOTE: Clearing the Energy Monitor counter will also clear the Filter Monitor counter , as Filter usage and T otal Energy usage are the same. Also[...]

  • Page 29

    Y our thermostat also keeps a record of the number of hours your filter has been in use. T o maximize your system’ s performance and ener gy efficiency , change or clean your filter regularly . NOTE: Clearing the Filter Monitor counter will also clear ALL Energy Monitor counters, as Filter usage and T otal Energy usage are the same. Also, clearin[...]

  • Page 30

    72 . 7I . 70 . 30-31 OPERA TION Auto Recovery Hunter’ s Auto Recovery feature meets the E NERGY S TA R ® guidelines for energy ef ficiency by allowing the heating or cooling system to recover gradually fr om an energy-saving setpoint temperatur e to a comfort setpoint temperature. Auto Recovery calculates how early to turn your system back On, s[...]

  • Page 31

    Backlighting (INDIGLO ® night-light) ■ Press the Light Bar on the left side of the thermostat to illuminate the display . ■ The display will remain illuminated for 5 seconds after the last key is pressed. This allows the light to stay on if you need to operate several keys. Note: If the thermostat is in Low Battery warning condition, the backl[...]

  • Page 32

    When the batteries become too weak for normal operation, the thermostat enters the second stage low battery warning which shuts down the thermostat. In this condition, “BA TT” flashes alone on the display , and the thermostat will tur n your system Off. Y our system will remain shut-off until the batteries ar e replaced. NOTE: The thermostat wi[...]

  • Page 33

    If the thermostat is unable to control your system due to an unexpected battery problem, the thermostat will enter Err or Mode. In this condition, the thermostat flashes “ERR-” on the LCD display , and shuts off your system. T o correct this pr oblem, replace the batteries with 2 new AA alkaline batteries, even if you have recently r eplaced th[...]

  • Page 34

    34-35 TROUBLESHOOTING Problem Solution SCRAMBLED OR DOUBLE DISPLA Y (numbers over numbers) NO DISPLA Y ENTIRE DISPLA Y DIMS PROGRAM DOES NOT CHANGE A T YOUR DESIRED SETTING AUTO / F AN DOES NOT TURN ON HEA TING OR COOLING DOES NOT GO ON OR OFF 1. Remove clear mylar sticker 1. Check battery connections and batteries. 2. Press RESET button with a sma[...]

  • Page 35

    Solution (cont.) ERRA TIC DISPLA Y IF UNIT CONTINUES TO OPERA TE IN THE OFF POSITION THERMOST A T PERMANENTL Y READS “HI,” “LO,” OR “ERR-” AFTER PRESSING RESET BUTTON 1. Press the RESET button once with a small pin and hold for two seconds. The thermostat will need to be repr ogrammed. 1. Replace unit. 1. Replace unit. If you experience[...]

  • Page 36

    36-37 WIRING DIAGRAMS 5-wire Heat/Cool System X - No Connection THERMOST A T G W Y RH RC Heat Relay or V alve Heat 24V Supply Fan Relay Cool Contactor Cool 24V Supply THERMOST A T G W Y RH RC Heat /Cool 24V Supply Fan Relay Heat Relay or V alve Cool Contactor Jumper 4-wire Heat/Cool System X O/B X O/B[...]

  • Page 37

    Single-stage Heat Pump THERMOST A T G W Y O/B RH RC Heat Pump 24V Supply Fan Relay Compressor Contactor Reversing V alve Jumper X - No Connection O/B 2-wire Heat Only THERMOST A T G W Y RH RC Heat Relay or V alve Heat 24V Supply X X X X X[...]

  • Page 38

    3-wire Cool Only 3-wire Heat Only THERMOST A T W RH RC Heat Relay or V alve Heat 24V Supply Fan Relay THERMOST A T G W Y RH RC Cool Contactor Fan Relay Cool 24V Supply G Y O/B O/B 38 WIRING DIAGRAMS X - No Connection X X X X X X Jumper[...]