Hunter Bath Ventilator Fan manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Hunter Bath Ventilator Fan, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hunter Bath Ventilator Fan one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Hunter Bath Ventilator Fan. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Hunter Bath Ventilator Fan should contain:
- informations concerning technical data of Hunter Bath Ventilator Fan
- name of the manufacturer and a year of construction of the Hunter Bath Ventilator Fan item
- rules of operation, control and maintenance of the Hunter Bath Ventilator Fan item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hunter Bath Ventilator Fan alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hunter Bath Ventilator Fan, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hunter service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hunter Bath Ventilator Fan.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Hunter Bath Ventilator Fan item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    2500 Frisco Avenue, Memphis, T ennessee 38114 Printed in China 41788-01 6/1/2005[...]

  • Page 2

    Installation Guide 82500 Infiniti™ Bath V entilator F an 41788-01 6/1/2005[...]

  • Page 3

    2 DISCONNECT ELECTRIC POWER SUPPL Y AND LOCK OUT SERVICE P ANEL BEFORE SERVICING UNIT W ARNING TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY , OBSERVE THE FOLLOWING: 1. For general ventilating use only. Do not use for ventilat- ing hazardous or explosive materials. 2. To avoid motor bearing damage and noisy/unbalanced impellers, keep drywall spray[...]

  • Page 4

    3 x4 3/8" Cable Connector * * * NO TE: Strain relief cable connector must be installed. Not Inc luded. A B C Extra Screws x2 H E D L 77864-02 F G H I J K 03242-07-133 96261-01-000 95047-02-000 74508-03-133 95776-01-000 75184-01-133 96258-01/02/03-008 75171-01/02/03-000 x2 Included. T urn off the power source. Before Installation Check all the [...]

  • Page 5

    A1 D Back out the pre-loaded screw tips until flush with the side of the housing. Remove the motor/blower from the housing. Remove the wiring cover screw . 4 Remove packing material. A2 A3 A6 F Loosen screw securing motor . A4 A 5 Remove the pre-loaded screw tip co vers. New Construction Installation 41788-01 6/1/2005[...]

  • Page 6

    A7 E A8 D A9 B C A 1 0 D 5/8 1/2 5/8 1/2 A 1 1 OPTION Remove the wiring cover . Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer . Position the correct depth mark at the bottom edge of the joist–based on the thickness of your sheet rock. Screw pre-loaded screws into j[...]

  • Page 7

    0 A 1 6 D A 1 2 A 1 3 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground A 1 4 Main Switch 1 (AC In) Switch 2 (AC In) *Option Fan & Main Light T ogether *Option D E A 1 5 F Pull the wires through the strain relief. Tighten the strain relief screws. Connect wires as shown. Connect a 4” duct a[...]

  • Page 8

    A2 2 C1 Go to step on page 12 to attach grille . 0 0 0 0 D A 1 7 G 0 0 0 0 G D A 1 8 A2 0 O N O F F A 2 1 Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Secure the motor by tightening the 2 screws.[...]

  • Page 9

    B3 7.25 ” 7.75 ” B1 D B2 Loosen screw securing motor . Remove the existing fan and check to make sure the opening is large enough to accommodate the new motor housing (7.25” x 7.75”) . Remove the motor/blower from the housing. Existing Construction Installation Existing F an 8 Remove packing material. D Use the motor housing as a template t[...]

  • Page 10

    B4 B 5 B8 D B9 B C Back out the pre-loaded screw tips until flush with the side of the housing. 9 B 6 E B7 E Remo ve the wiring cover . Remove the wiring cover screw . Remove the pre-loaded screw tip co vers. 41788-01 6/1/2005 Insert the strain relief into the housing and secure with the washer . Pop out the first wiring access slug. Use second if [...]

  • Page 11

    D B 1 0 Fit housing into the opening and secure by tightening the pre-loaded screws into the joist. Note: Install the box flush with the sheetrock (ceiling). B 1 1 2 1 B 1 2 D B 1 3 D B 1 4 10 Pull the wires through the strain relief and tighten the strain relief screws. Attach existing ducting to duct connector . T ape joints. If ducting does not [...]

  • Page 12

    D E F B 1 6 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground B 1 5 Main Switch 1 (AC In) Switch 2 (AC In) *Option Fan & Main Light T ogether *Option D B 1 7 0 0 0 0 G D B 1 8 Install the wiring co ver plate. Make sure all wiring connections are inside the box or under the wiring cover plate.[...]

  • Page 13

    B 2 0 O N O F F B 2 1 B 2 2 C1 Go to step to attach grille . 12 J C 1 T est the motor . If the motor does not run, check the plug connection. T urn on the power source. Attaching the Grille C 2 K L I 41788-01 6/1/2005 Remove the thumbscrews. Remove glass dome.[...]

  • Page 14

    Connect wiring harness. I C 3 C 4 I Slide light mount over posts. Attach thumbscrews. WARNING: T o reduce the risk of electrical shock, all 3 thumbscrews MUST be properly installed. I J C 5 Install 2 Max 60 Watt A15 bulbs (Not Inc luded). C 6 Screw glass dome into position. Align glass dome and push up. K C 7 L C 8 41788-01 6/1/2005 13[...]

  • Page 15

    14 41788-01 6/1/2005 T rouble Shooting Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel the air movement. • Turn power on, replace fuse, or reset breaker. • Check all plug connections to be sure they are secure. • Check the[...]

  • Page 16

    W arranty Hunter Fan Company Bath Exhaust Fan LIMITED W ARRANTY Hunter Fan Company makes the following limited warr anty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within one year after the date of sale to you [...]