hussman DBP manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of hussman DBP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of hussman DBP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of hussman DBP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of hussman DBP should contain:
- informations concerning technical data of hussman DBP
- name of the manufacturer and a year of construction of the hussman DBP item
- rules of operation, control and maintenance of the hussman DBP item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of hussman DBP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of hussman DBP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the hussman service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of hussman DBP.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the hussman DBP item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    /Chino DBP , DBRP 01,03 ISLAND PRODUCE REV .0210 Installation & Operation Manual DBP , DBRP 01,03 ISLAND PRODUCE P/N IGIP-DBP , DBRP 01,03-0210 INST ALLA TION & O P ER A T IO N GUIDE[...]

  • Page 2

    IGIP-DBP, DBRP 01,03-0210 2 /Chino A publication of Hussmann ® Chino 13770 Ramona A venue • Chino , California 91710 (909) 628-8942 F AX (909) 590-4910 (800) 395-9229 K eep this booklet with the case at all times for futur e r efer ence . THIS BOOKLET CONT AINS INFORMA TION ON: DBP , DBRP 01,03 Island Produce Cases SHIPPING D AMA GE All equipmen[...]

  • Page 3

    Rev.0 210 3 Cut & Plan Views DBP-03 Standard Section Produce Scale = 3/8" 38 1 / 2 " 70 1 / 4 " 26 1 / 8 " 35 1 / 4 " 30" 15 3 / 4 "1 5 3 / 4 " Optional Base Display 11 " 14 1 / 4 " 4" 26 1 / 8 " 20 1 / 8 " 5'-10 1 / 8 " 41 5 / 8 " DBRP Straight Section Scale = 1/4&[...]

  • Page 4

    IGIP-DBP, DBRP 01,03-0210 4 LOCA TION The refrigerated mer chandisers ha ve been designed f or use only in air conditioned stor es where temperatur e and humidity ar e maintained at or below 75 ° F and 55% rela- tive humidity . DO NO T allow air conditioning, electric fans, ov ens, open doors or windows (etc.) to create air cur - r ents ar ound th[...]

  • Page 5

    Rev.0 210 5 SETTING AND JOINING The sectional construction of these models enable them to be joined in line to giv e the effect of one continuous displa y . A joint trim kit is supplied with each joint. LEVELING IMPOR T ANT! IT IS IMPERA TIVE THA T CASES BE LEVELED FROM FR ONT T O BA CK AND SIDE T O SIDE PRIOR T O JOIN- ING. A LEVEL CASE IS NECESSA[...]

  • Page 6

    IGIP-DBP, DBRP 01,03-0210 6 Plumbing WASTE OUTLET AND P-TRAP The waste outlet is located off the center of the case on one side allowing drip piping to be run lengthwise under the fixture. A 1-1/2" P-trap and thr eaded adapter are supplied with each fixture. The P-trap must be installed to pr event air leakage and insect entrance into the fixt[...]

  • Page 7

    Rev.0 210 7 REFRIGERANT TYPE The standard r efrigerant will be R-22 unless otherwise specified on the customer or der . Check the serial plate on the case for inf ormation. PIPING The refrigerant line outlets ar e located under the case. Locate first the electrical box, the outlets are then on the same side of the case but at the opposite end. Insu[...]

  • Page 8

    IGIP-DBP, DBRP 01,03-0210 8 Electrical WIRING COLOR CODE GREEN GROUND PURPLE ANTI-SWEA T ORANGE LIGHTS YELLOW RECEPT ACLE RED / BLACK T -ST A T /SOLENOID 230V BLACK / WHITE T - S TAT / S O L E N O I D 115V BRO WN F AN MO TORS CASE MUST BE GROUNDED NOTE: Refer to label affixed to case to determine the actual configuration as checked in the “TYPE I[...]

  • Page 9

    Rev.0 210 9 User Information STOCKING Improper temperatur e and lighting will cause serious pr od- uct loss. Discoloration, dehydration and spoilage can be contr olled with proper use of the equipment and handling of pr oduct. Pr oduct temperature should alwa ys be main- tained at a constant and pr oper temperature. This means that fr om the time t[...]

  • Page 10

    IGIP-DBP, DBRP 01,03-0210 10 Maintenance ELECTRICAL PRECAUTIONS BEFORE SERVICING – Always disconnect electrical power at the main disconnect when servicing or replacing any electrical component This includes (but not limited to) Fans, Heaters, Thermostats, and Lights. REPLACING FLUORESCENT LAMPS Fluorescent lamps ar e furnished with a shatterpr o[...]

  • Page 11

    Rev.0 210 11 Electrical and Refrigeration Specifications TEMPERATURE DISCHG. FAN SIZE DEFROST ELECTRICAL CIRCUITS SELF CONTAINED UNIT DATA BTU AVG AIR T-STAT/ TYPE & FREQ. 115 V. SELF CONTAINED REQ’D EVAP PROD DISC VELOC CUT IN OF NUMBER & E E FANS STD. LOW PRESSURE LENGTH PER FT. TMP TMP TMP @FPM SETTINGS COIL OF MOTORS DURATION (OPT.) F[...]

  • Page 12

    IGIP-DBP, DBRP 01,03-0210 12 Electrical Schematics By: Checked By: No. Descripti on: Revisions: dbrp-01.dft Hussmann Corp oratio n 137 70 Ramona Avenue Chino , CA . 91710 (909)- 590- 491 0 Lic.#: 64440 6 Date: Drawing Title: Next A ssembly: Drawn By: Drawing N o.: Pro ject Title: Date: Ab raham C . Hui ACH 07/29/9 8 X Sheet 1 of 1 DBRP-01/03 Wiring[...]

  • Page 13

    Rev.0 210 13 MOT OR MOT OR MOT OR S S Brow n General Grounding Area To Sensors Case Controller Com puter Red (115/230V. ) Black/ White (115V. ) T-Sta t Liqu id So lenoid (Optio nal) (Optio nal) Electronic TXV MOTO R MOT OR 8' 12' 16' B B B Or ange Light S witch Lithonia se lf contained Led ge Lights ( Optional) ( No. of la m ps varie[...]

  • Page 14

    IGIP-DBP, DBRP 01,03-0210 14 MO TO R MOT OR MO TO R S S Brown G ene ral Grou nding Are a To S e nsors Case Contro ller Comp ut e r Red (1 15/230V.) Black/Whi te ( 115V.) T-Stat Liquid Solenoi d (Op t iona l) (Opti onal) La beled "C ontroller" MO TO R MO TO R B232I120 B332I120 B332 I120 F17T 8 - SPX41 Ba llast Ba llast Ballast MO TO R MOT [...]

  • Page 15

    Rev.0 210 15 APPENDIX A. – Temperature Guidelines Refrigerated The refrigerators should be operated according to the manufacturer’s published engineering specifications for entering air temperatures for specific equipment applications. Table 1 shows the typical temperature of the air entering the food zone one hour before the start of defrost a[...]

  • Page 16

    IGIP-DBP, DBRP 01,03-0210 16 potentially hazardous food. 1.1 The following recommendations are made for the purpose of arriving at easily taken and understood data which, coupled with other observations, may be used to determined whether a display refrigerator is working as intended: a) INSTRUMENT – A stainless steel stem-type thermometer is reco[...]

  • Page 17

    Rev.0 210 17 d) Care must be taken when cross merchandising products to ensure that potentially hazardous vegetable products are not placed in non refrigerated areas. e) Display and storage equipment doors should be kept closed during periods of inactivity. f) Minimize the transfer time of perishables from storage to display. g) Keep meat under ref[...]

  • Page 18

    IGIP-DBP, DBRP 01,03-0210 18[...]

  • Page 19

    Rev.0 210 19 Limited W arranty This warranty is made to the original user at the original installation site and is not transf erable . Hussmann merchandisers ar e war ranted to be free fr om def ect in material and workmanship under normal use and ser vice f or a period of one (1) year fr om the date of original installation (not to exceed fifteen [...]

  • Page 20

    IGIP-DBP, DBRP 01,03-0210 20 The MODEL NAME and SERIAL NUMBER is required in or der to pr ovide you with the correct parts and information for y our particular unit. They can be found on a small metal plate on the unit. Please note them below for futur e reference. MODEL: SERIAL NUMBER: /Chino Additional copies of this publication ma y be obtained [...]